MAINTENANCE AND CLEANING

 ■

Before cleaning the portable air conditioner, turn it off and wait a few minutes, and 

then pull the power cord out of the power socket.

Cleaning the air filter

 ■

When the portable air conditioner is used regularly, it is necessary to clean the air 

filter located behind the protective grille 

A9

 at least once a week to prevent the fan 

from being clogged by dust.

 ■

Carefully remove the protective grille and remove the filter – see fig. 

F

. To remove 

the dust, use a vacuum cleaner. In the event of greater soiling, hand wash the filter in 

a solution of lukewarm water (max. 40 °C.) and neutral detergent. Then thoroughly 

rinse under running water and allow to dry naturally. Do not dry it in a clothes dryer 

or in direct sunlight. Once the filter is dry, you can install them back in their place.

Note

Do not use the portable air conditioner without the air filter properly 

installed and do not use it with wet or damp air filter.

Cleaning the outer case

 ■

To clean the outer case, use a soft wiping cloth dipped in a solution of lukewarm 

water and neutral detergent. Then wipe the surface dry.

 ■

When cleaning it, do not spray the portable air conditioner with water or any other 

liquid, do not pour water on it or submerge it in water or in any other liquid.

 ■

Do not use abrasive cleaning products, solvents, petrol, etc. for cleaning.

Storing the portable air conditioner

 ■

In order to dry it and to prevent the formation of moulds, leave the portable air 

conditioner running in a warm room in the fan mode for approximately 12 hours.

 ■

Disconnect the flexible hose 

B4

 and store it in a  safe place out of the reach of 

children.

 ■

Drain all the condensate from the water tank – see chapter „

Condensate water 

drainage

“.

 ■

Clean the air filter and reinstall it. Wipe the outer case of the portable air conditioner. 

Remove the batteries from the remote control.

 ■

Store the air conditioner in a cool, dry, and dark location.

CONDESATE WATER DRAINAGE

 ■

The portable air conditioner is provided by two drain outlets where each drains 

the condensate water from a different part of the air conditioner. In the event of 

a frequent use of the portable air conditioner, it is necessary to regularly check the 

condensate water status and drain it. If the dehumidification mode is selected, it is 

advised to drain the condensate water using the drain hose 

B8

 which is connected 

either to the top drain outlet or bottom drain outlet.

Note:

It is not necessary to drain the condensate water in cooling or fan modes 

(provided low humidity in the room). The portable air conditioner is 

designed to increase its efficiency with a small amount of water in the 

condensate tank.

CONDENSATE WATER DRAINAGE FROM THE BOTTOM DRAIN OUTLET

 ■

Once the water level in the tank reaches the preset level, the operation of the 

portable air conditioner stops and the display 

C5

 shows “Ft” (full tank). To drain the 

condensate water from the air conditioner, proceed as follows:

  1. Disconnect the power plug from the power socket.

  2.   Carefully re-locate the portable air conditioner to a location where the water may 

be drained.

  3.  Underneath the drain outlet 

A8

, place a  container into which the condensate 

water will flow. Carefully remove the plug of the drain outlet 

A8

. Connect the 

drain hose 

B8

 and allow the condensate water to flow out.

  4.  

Once the water tank is empty (condensate water has stopped flowing), 

disconnect the drain hose 

B8

 and put the plug back into the drain outlet 

A8

.

  5.  Insert the power plug into a  power socket and turn on the portable air 

conditioner.

 ■

If you need to ensure the condensate water to be continuously drained from the 

portable air conditioner, it is possible to connect the drain hose 

B8

 to a waste water 

drain. Proceed as follows:

  1.  Disconnect the power plug from the power socket.

  2.   Remove the plug of the drain outlet 

A8

 – see fig. 

G1

. Connect the drain hose – see 

fig. 

G2

. If the length of the drain hose 

B8

 is insufficient, then it is necessary to 

purchase a longer hose of the same type. Never extend the length of the drain 

hose 

B8

 using extensions.

  3.  Connect the end of the drain hose 

B8

 to the waste water drain.

  4.  Insert the power plug into a  power socket and turn on the portable air 

conditioner.

Note:

The drain hose 

B8

 should be installed at the same height or lower than 

the drain outlet 

A8

 – see fig. 

G3

. Otherwise, the condensate water will not 

be properly drained from the water tank.

Condensate water drainage from the top drain outlet

In the dehumidification mode, you can use the top drain outlet 

A7

 for a continuous 

drainage of the condensate water.

  1.  Disconnect the power plug from the power socket.

  2.  Remove the plug of the drain outlet 

A7

 – see fig. 

H1

. Connect the drain hose 

B8

 

– see fig. 

H2

. If the length of the drain hose 

B8

 is insufficient, then it is necessary 

to purchase a longer hose of the same type. Never extend the length of the drain 

hose 

B8

 using extensions.

  3.  Connect the end of the drain hose 

B8

 to the waste water drain.

  4.  Insert the power plug into a  power socket and turn on the portable air 

conditioner.

Note:

The drain hose 

B8

 should be installed at the same height or lower than 

the drain outlet 

A7

 – see fig. 

H3

. Otherwise, the condensate water will not 

be properly drained from the water tank.

Putting into operation again

Check that the power cord and plug are not damaged and that the air filter is clean. 

Insert a  new set of batteries into the remote control. Proceed according to the 

instructions in section „

Inserting and replacing batteries

“. Install the portable air 

conditioner according to the instructions contained in the preceding part of this 

user‘s manual „

Installation

“.

TROUBLESHOOTING

Error message

Shown on 

the display

Meaning

Solution

Defect on the 

heat sensor

Contact an authorised service centre.

Full tank

Empty the condensate tank. Proceed according 

to the instructions in section „

Condensate 

water drainage

“ described previously in this 

user‘s manual.

Note:

The drain hose 

B8

 should be installed at the same height or lower than 

the drain outlet 

A7

 – see fig. 

H3

. Otherwise, the condensate water will not 

be properly drained from the water tank.

Troubleshooting

 ■

Before contacting an authorised service centre, please check the appliance 

according to the following instructions:

Problem

Possible cause

Remedy

The portable air 

conditioner did not 

turn on.

There is no current in the 

power socket.

Engage the circuit breaker or, 

alternatively, try a different 

power socket.

The power plug is not inserted 

in a power socket.

Connect the power plug to 

the power socket.

The internal safety fuse is 

disengaged.

Wait 30 minutes, and if the 

problem persists, please 

contact an authorised service 

centre.

The portable air 

conditioner runs 

only for a short time.

The flexible air exhaust hose 

B4

 is not connected or it is 

blocked.

Turn off the air conditioner, 

disconnect the hose, check 

that it is not blocked and 

reconnect the hose.

Air inlets are blocked.

Remove the obstacles 

preventing air supply to 

the inlets.

The portable air 

conditioner is on, 

but is not cooling.

The windows and doors of 

the room are open and hot air 

comes into the room.

Make sure that all doors and 

windows are closed.

There are heat sources on 

inside the room.

If possible remove these heat 

sources.

The flexible air exhaust hose 

B4

 is not connected.

Attach the flexible hose 

B4

.

The room area is too large.

Perform a double-check of 

the cooled area.

An unpleasant odour 

is sensed while it is 

running.

The air filter is clogged with 

dirt and dust or animal fur.

Turn off the air conditioner 

and clean the filter according 

to the provided instructions.

The portable air 

conditioner turns off 

approx. 3 minutes 

after it is turned on 

again.

The compressor's safety fuse is 

protecting the air conditioner 

against damage if turned on 

sooner than after 3 minutes.

Wait several minutes and 

then turn the air conditioner 

on again.

An error message 

appeared on the 

display 

C5

.

Proceed according to the 

instructions in section "

Error 

messages

".

Summary of Contents for SAC MT7007C

Page 1: ...1 04 2021 Copyright 2021 Fast R a s EN Portable Air Conditioner Translation of the original manual SAC MT7007C...

Page 2: ...e used by children 8 years of age and older and by persons with physical sensory or mental impairments or by persons with a lack of experience or knowledge if they are properly supervised or have been...

Page 3: ...ower socket must be freely accessible so that it is possible to quickly disconnect the power cord from the power source if necessary The appliance is designed for use at home in offices and similar ty...

Page 4: ...ion of at least 30 cm on all sides of the appliance Do not expose yourself to a cold air current for a long time This could have a negative effect on your health To turn the appliance on or off always...

Page 5: ...by electrical shock or fire To prevent the risk of fire or injury by electrical shock do not use this appliance with a timer or any another similar device that could spontaneously start this appliance...

Page 6: ...disconnect the unit from the power socket If the unit is tipped over during use turn it off and immediately disconnect it from the main power supply Visually check that the unit has not been damaged...

Page 7: ...iance contains approx 170 g of refrigerant gas R290 R290 is a refrigerant gas that complies with the European directives on the environment Do not puncture any part of the refrigerant circuit If the a...

Page 8: ...manufacturing company Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrig...

Page 9: ...9 04 2021 Copyright 2021 Fast R a s SAC MT7007C A 1 2 3 9 10 11 12 4 5 6 7 8 B 2 3 4 5 6 7 8 1...

Page 10: ...10 04 2021 Copyright 2021 Fast R a s 2 1 6 7 8 3 4 5 9 10 11 12 13 14 C 1 2 3 4 5 6 7 8 D E...

Page 11: ...11 04 2021 Copyright 2021 Fast R a s F G1 G2 G3 H1 H2 H3...

Page 12: ...ypes of slide windows it may be necessary to modify the installation procedure described below Open the sliding window sash and place the window insert into the window Adjust the dimensions of the win...

Page 13: ...n the display C5 In this mode it is not possible to set the temperature nor it is necessary to connect the flexible hose B4 to the portable air conditioner Note In the fan mode it is not possible to s...

Page 14: ...se see fig G2 If the length of the drain hose B8 is insufficient then it is necessary to purchase a longer hose of the same type Never extend the length of the drain hose B8 using extensions 3 Connect...

Page 15: ...ifications DISPOSAL OF USED BATTERIES Batteries contain environmentally damaging compounds and therefore do not belong in standard communal waste Hand over used batteries for proper disposal at locati...

Reviews: