Sencor SAC MT7007C Translation Of The Original Manual Download Page 12

- 12 -

 

04/2021

 Copyright © 2021, Fast ČR, a.s.

EN

Portable Air Conditioner

User´s manual

 ■

Prior to using this appliance, please read the user‘s manual thoroughly, even in cases, 

when one has already familiarised themselves with previous use of similar types of 

appliances. Only use the appliance in the manner described in this user’s manual. 

Keep this user‘s manual in a safe place where it can be easily retrieved for future use.

 ■

We recommend saving the original cardboard box, packaging material, purchase 

receipt and responsibility statement of the vendor or warranty card for at least the 

duration of the legal liability for unsatisfactory performance or quality. In the event 

of transportation, we recommend that you pack the appliance in the original box 

from the manufacturer.

DESCRIPTION OF THE APPLIANCE

A1 

Control panel

A2 

Air outlet

A3 

Remote control storage slot

A4 

Handles (located along both sides)

A5 

Travel wheels

A6 

Universal power cord plug plate

A7 

Top drain outlet

A8 

Bottom drain outlet

A9 

Removable grille with filter (top 

evaporator air inlet is located under 

the grille)

A10 

Air outlet to connect the flexible 

hose

A11 

Bottom air inlet of the condensation 

unit

A12 

Power cable

DESCRIPTION OF THE ACCESSORIES

B1 

Remote control (batteries included)

B2 

Sealing kit for roof, sash, and tilt-

open windows:

 

- textile protection with a zip

 

- tape of self-adhesive velcro

B3 

Plastic window set for sliding and 

roof windows (screws included)

B4 

Wide flexible hot air exhaust hose

B5 

Inlet hose adaptor

B6 

Outlet hose adaptor

B7 

Sealing

B8 

Drain hose

DESCRIPTION OF THE CONTROL PANEL

C1 

Timer indicator

C2 

Wi-Fi indicator (valid only for Wi-Fi 

models)

C3 

Low speed fan indicator

C4 

High speed fan indicator

C5 

Display

C6 

Cooling mode indicator

C7 

Dehumidification mode indicator

C8 

Fan mode indicator

C9 

 button to set the timer

C10 

 button to set the fan speed

C11 

+ button

C12 

– button

C13 

 button to select an operation 

mode

C14 

 button to turn on / off

REMOTE CONTROL

D1 

 button to turn on / off

D2 

 to select an operation mode

D3 

+ button

D4 

 button to set the timer

D5 

 button to set the sleep mode

D6 

– button

D7 

 button to set the fan speed

D8 

°C / °F button to change the 

temperature unit

Note

The SWING

 

 function is available only for certain models.

INSTALLATION

Location of the portable air conditioner

 ■

Locate the portable air conditioner on an even, dry, and stable surface and within 

reach of a grounded power socket.

 ■

For easier handling, the portable air conditioner is equipped with travel wheels 

A5

Do not use the travel wheels 

A5

 when you need to move the air conditioner over 

carpets or similar surfaces. Avoid riding over objects.

 ■

To achieve optimal efficiency, maintain a distance of at least 45 cm from the wall 

or other obstacles.

Warning:

Do not block the air inlet or air outlet.

Note:

Do not use the portable air conditioner to cool a room where computer 

servers, etc. are located.

Installation, adjustment, maintenance, and repairs must only be 

performed by a qualified person.

Installation of flexible hose on to the portable air conditioner

 ■

The flexibl hose 

B4

 must be connected to the portable air conditioner and installed 

into a window in accordance with the operating modes that you wish to set. Install 

the flexible hose 

B4

 when you wish to select the operating modes: cooling and 

dehumidification.

 ■

Extend the flexible hose 

B4

 to the required length. Fix the inlet hose adaptor 

B5

 on 

to the end of the flexible hose 

B4

. Place it over the air outlet 

A10

 and fix it on the air 

outlet 

A10

 by moving it down.

 ■

Fix the outlet hose adaptor 

B6

 on to the second end of the flexible hose 

B4

.

Note:

Avoid excessive bending of the hose – see fig. E. To ensure the proper 

operation of the portable air conditioner, it is important not to overload 

the hose, or to bend it unnecessarily. Excessive loading or bending may 

damage the hose.

Installation of flexible hose into a slide window

 ■

The window insert is designed to be compatible with the majority of sliding 

windows (vertical and horizontal). Nevertheless, for certain types of slide windows it 

may be necessary to modify the installation procedure described below.

 ■

Open the sliding window sash and place the window insert into the window. Adjust 

the dimensions of the window insert to the width of the window (on a  vertical 

slide window) / height of the window (on a horizontal slide window). If necessary, 

cut away a part of the window insert if the window is too small. Close the sliding 

window sash to the window insert. Insert the flexible hose 

B4

 with attached outlet 

hose adaptor 

B6

 into the hole in the window insert.

Installation of flexible hose using the sealing kit

 ■

The sealing kit 

B2

 is suitable for tilt-open, sash and roof windows. The textile 

protection is easy to install in the window using the Velcro. Open the window 

and into the created crevice install the tape of Velcro. We recommend that you 

thoroughly degrease the location where you will be attaching the tape of Velcro 

using an appropriate cleaning agent. Remove the protective paper strip and stick 

the tape on to the window frame.

 ■

To be able to insert the flexible hose 

B4

, the textile protection is fitted with an 

integrated zip. Open the zip in such a location that will enable you to easily insert 

the flexible hose 

B4

.

 ■

It is not necessary to remove the sealing kit 

B2

 from the window when not using the 

portable air conditioner. The window can be still closed.

OPERATION OF THE PORTABLE AIR CONDITIONER

A. CONTROL PANEL

 ■

Insert the power plug into a power socket. Now, the portable air conditioner sets 

itself to the stand-by mode.

Turning the portable air conditioner on and off

 ■

To turn on the portable air conditioner, press the   button 

C14

. Press it again to 

switch the portable air conditioner to the stand-by mode.

Note:

Never turn off the portable air conditioner by pulling the power cord out 

of the power socket. Turn off the portable air conditioner using the   

button 

C14

, wait a few minutes and then pull out the power cord.

OPERATING MODES

1. Cooling mode

 ■

Repeatedly press the 

 button 

C13

 until the cooling indicator 

C6

 is lit. Use the 

+/- buttons to set the desired temperature. You can set the temperature in the range 

from 18 to 32 °C. The set temperature is shown on the display 

C5

.

 ■

Use the 

 button 

C10

 to set the fan speed in the following order: High (high 

speed) – Low (low speed). Each time the button is pressed, the respective indicator 

will be lit on the control panel 

A1

.

2. Fan mode

 ■

Repeatedly press the 

 button 

C13

 until the fan indicator 

C8

 is lit. Use the 

 

button 

C10

 to set the fan speed in the following order: High (high speed) – Low (low 

speed). Each time the button in pressed, the respective indicator will be lit on the 

control panel 

A1

 and at the same time, the respective graphic symbol (

 symbol 

for high speed;

 symbol for low speed) will be lit on the display 

C5

. In this mode, 

it is not possible to set the temperature, nor it is necessary to connect the flexible 

hose 

B4

 to the portable air conditioner.

3. Dehumidification mode

 ■

Ensure the flexible hose 

B4

 is connected to the air conditioner. Repeatedly press 

the 

 button  

C13

 until the dehumidification indicator 

C7

 is lit. The display 

C5

 

shows 

. In this mode, it is not possible to set the temperature or fan speed. The 

fan speed is automatically set.

FUNCTIONS OF THE PORTABLE AIR CONDITIONER

1. Automatic turn-on function

 ■

Turn the portable air conditioner on by pressing the   button 

C14

. Use the 

 

button 

C13

 to select the operation mode in which you wish to turn the portable 

air conditioner on. Use the +/- buttons to set the desired temperature and use the 

button 

w

 to set the fan speed as required. Press the   button 

C14

 to turn the 

portable air conditioner off.

 ■

Now, press shortly once 

 button 

C9

. Press the 

 button 

C9

 repeatedly to set 

the time after which the portable air conditioner will turn on automatically. You can 

set the time of the automatic turn-on function in the range from 1 up to 24 hours.

 ■

After a few seconds, the set time will be saved in the air conditioner memory and the 

automatic turn-on indicator will be lit on the display 

C5

. Once the set time elapses, 

the portable air conditioner will turn on automatically.

 ■

If you press 

 button 

C9

 or   button 

C14

 after the automatic turn-on function is 

set, the setting will be automatically cancelled.

Summary of Contents for SAC MT7007C

Page 1: ...1 04 2021 Copyright 2021 Fast R a s EN Portable Air Conditioner Translation of the original manual SAC MT7007C...

Page 2: ...e used by children 8 years of age and older and by persons with physical sensory or mental impairments or by persons with a lack of experience or knowledge if they are properly supervised or have been...

Page 3: ...ower socket must be freely accessible so that it is possible to quickly disconnect the power cord from the power source if necessary The appliance is designed for use at home in offices and similar ty...

Page 4: ...ion of at least 30 cm on all sides of the appliance Do not expose yourself to a cold air current for a long time This could have a negative effect on your health To turn the appliance on or off always...

Page 5: ...by electrical shock or fire To prevent the risk of fire or injury by electrical shock do not use this appliance with a timer or any another similar device that could spontaneously start this appliance...

Page 6: ...disconnect the unit from the power socket If the unit is tipped over during use turn it off and immediately disconnect it from the main power supply Visually check that the unit has not been damaged...

Page 7: ...iance contains approx 170 g of refrigerant gas R290 R290 is a refrigerant gas that complies with the European directives on the environment Do not puncture any part of the refrigerant circuit If the a...

Page 8: ...manufacturing company Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrig...

Page 9: ...9 04 2021 Copyright 2021 Fast R a s SAC MT7007C A 1 2 3 9 10 11 12 4 5 6 7 8 B 2 3 4 5 6 7 8 1...

Page 10: ...10 04 2021 Copyright 2021 Fast R a s 2 1 6 7 8 3 4 5 9 10 11 12 13 14 C 1 2 3 4 5 6 7 8 D E...

Page 11: ...11 04 2021 Copyright 2021 Fast R a s F G1 G2 G3 H1 H2 H3...

Page 12: ...ypes of slide windows it may be necessary to modify the installation procedure described below Open the sliding window sash and place the window insert into the window Adjust the dimensions of the win...

Page 13: ...n the display C5 In this mode it is not possible to set the temperature nor it is necessary to connect the flexible hose B4 to the portable air conditioner Note In the fan mode it is not possible to s...

Page 14: ...se see fig G2 If the length of the drain hose B8 is insufficient then it is necessary to purchase a longer hose of the same type Never extend the length of the drain hose B8 using extensions 3 Connect...

Page 15: ...ifications DISPOSAL OF USED BATTERIES Batteries contain environmentally damaging compounds and therefore do not belong in standard communal waste Hand over used batteries for proper disposal at locati...

Reviews: