Senco ACCUSET PC2053-1 Owner'S Manual Download Page 16

ACCUSET COMPRESSOR AND PARTS WARRANTY

This compressor has been designed and constructed using the highest standards of material and workmanship.

COMPRESSOR WARRANTY:

The length of this guarantee is 

one year

 from date of purchase by the 

original retail purchaser.

  During this period, Senco

Products, Inc., will repair or replace at Senco’s option, any original part or parts for the original retail purchaser.  This will be done free of
charge, provided the parts are determined defective in materials or workmanship upon examination by a Senco/Accuset  Authorized Warranty
Service Center, with the exceptions and exclusions described below.  Any replacement part provided will carry a warranty for the balance
of the period of warranty applicable to the part it replaces.  When repair or replacement of parts or compressor is necessary, the original retail
purchaser returns the complete compressor or part, with transportation prepaid, to the nearest Senco/Accuset Authorized Warranty Service
Center, with purchase receipt or other positive proof that the part or compressor is within the warranty period.

Accuset  warrants all parts (except those listed below) of your Accuset air compressor to be free from defects in materials and workmanship
during the following periods:

1. For 1 year from date of original purchase:

Compressor Pump

Pilot Valve

Tank Assembly

Plumbing

Flywheel

Throttle Control

Power Cord

2. For 90 days from date of original purchase:

Pressure Gauge

Pressure Relief Valve

Draincocks

Defective parts not subject to normal wear and tear will be repaired or replaced, at our (Senco’s) option, during warranty period.  In any
event, reimbursement is limited to the purchase price paid.

EXCLUSIONS:

1. Engine/Motor is covered under separate warranty by its respective manufacturer and is subject to the terms set forth therein.
2. Normal wear parts not covered under warranty:

Isolators

Drive Belt

Air Filter

3. This warranty does not cover parts damaged due to normal wear, misapplication, misuse, accidents, operation at other
    than recommended speeds or voltage (electric units only), improper storage, or damages resulting during shipping.
4. Deviation from operating instructions, specifications, and maintenance schedules.
5. Labor charges, loss or damage resulting from improper operation, maintenance or repairs made by person(s) other than a
    Senco/Accuset  Authorized Warranty Service Center.
6. The use of other than genuine Accuset  Repair Parts will void warranty.

This warranty is contingent upon proper use of the compressor by purchaser and does not cover:

(A) Abnormal conditions, accident, neglect, misuse or improper storage of the unit.
(B) Deviation from operating or maintenance instructions.
(C) Modifications not authorized by Senco.
(D) Repairs or maintenance (other than routine air tank draining and oil filter changes required by your operating and
      maintenance manual) made by persons other than Senco or its authorized agents.
(E) Freight damage.

THIS WARRANTY IS THE ONLY WARRANTY ON THIS COMPRESSOR, AND ALL OTHER WARRANTIES, WHETHER ORAL,

WRITTEN, EXPRESS, OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, ARE EXCLUDED.  BUYER’S OR USER’S REMEDIES ARE SOLELY AND EXCLUSIVELY AS STATED ABOVE.
SENCO PRODUCTS, INC. SHALL IN NO EVENT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, OR SPECIAL DAMAGES.
IN NO EVENT, WHETHER AS A RESULT OF A BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE) OR OTHERWISE,
SHALL SENCO’S LIABILITY EXCEED THE PRICE OF THE COMPRESSOR WHICH HAS GIVEN RISE TO THE CLAIM OR LIABILITY.  ANY
LIABILITY CONNECTED WITH THE USE OF THIS COMPRESSOR SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY
PERIOD SPECIFIED ABOVE.

Replacement of Compressor Due to Natural Disaster

Senco will also replace any compressor destroyed by an Act of God such as flood, earthquake, hurricane or other disaster resulting only
from the forces of nature.  Such a claim will be honored provided that such original retail purchaser had previously submitted a completed
warranty registration card, and then submits proof of ownership and an acceptable statement describing such Act of God documented
by an insurance carrier, police department, or other official governmental source.  To obtain instructions for filing a claim call 1-888-222-
8144.

SENCO PRODUCTS, INC.

CINCINNATI, OHIO  45244-1611 USA

Summary of Contents for ACCUSET PC2053-1

Page 1: ...ircuit breaker is preferred Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR P...

Page 2: ...in minor or moderate injury This manual contains information that is important for you to know and understand This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To h...

Page 3: ...IN WITH UNIT AT ALL TIMES RISK OF EXPLOSION OR FIRE AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SE...

Page 4: ...SSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL OR SAFETY DATA SHE...

Page 5: ...TECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL WHAT CAN HAPPEN HOW TO PREVENT IT A PORTABLE COMPRESSOR CAN FALL FROM A TABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE COM PRE...

Page 6: ...ord and air hose from damage by winding them loosely around the air compressor 4 Store the air compressor in a clean and dry location When you have finished using the air compressor This air compresso...

Page 7: ...ssure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pressure Regulator The air pressure coming from the air tank is controll...

Page 8: ...The outlet must have the same configuration as the plug See illustration DO NOT USE AN ADAPT ER Inspect the plug and cord before each use Do not use if there are signs of damage IMPROPER GROUNDING CAN...

Page 9: ...e tank Close the regulator when tank pres sure is approximately 20 psi 10 Drain water from air tank by opening drain valve underneath the tank 11 After the water has been drained close the drain valve...

Page 10: ...ective air tank Itisnormalfor some pressuredropto occur Movethepressureswitchlevertothe OFF position If the unit doesn t shut off and the electrical contacts are welded together replace the pressure s...

Page 11: ...t in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Check for proper gauge wire and cord length Remove and clean or replace Have checked at a...

Page 12: ...12 ENG D23708 SSP 473 CAC 1275 SST 5314 1 SSF 607 AC 0430 CAC 1254 SSP 480 SUDL 403 1 SSW 7480 TIA 4150 SS 1286 CAC 4296 1 AC81 B SSF 621 GA 352 SSP 6021 DAC 4105 2 SSW 7367 SUDL 9 1 PARTS DIAGRAM...

Page 13: ...Relief CAC 1275 Check Valve SSP 473 Nut Sleeve Only Availiable with Pressure Switch DAC 4105 2 SUDL 9 1 Screw 8 32 x 375 344 2 used SSP 480 Nipple SSW 7367 Bushing Strain Relief SUDL 403 1 Cord Assemb...

Page 14: ...14 ENG D23708 CAC 1212 CAC 1206 1 DAC 269 SSF 3147 AC 0206 AC 0815 AC 0470 SUDL 9 1 D23584 D21919 CAC 1199 CAC 1213 CAC 1213 AC 0471 SSF 3156 SSG 8169 CAC 1196 SSF 995 CAC 4323 AIR COMPRESSOR DIAGRAM...

Page 15: ...ring Rod Assembly x SSF 3147 Screw 3 8 16 socket head Cylinder Sleeve D23584 Endbell Assembly AC 0815 Timing Belt CAC 1213 Pump Isolator 5 used x SUDL 9 1 Screw 8 32x 375 344 AC 0471 Shroud Left AC 04...

Page 16: ...improper storage or damages resulting during shipping 4 Deviation from operating instructions specifications and maintenance schedules 5 Labor charges loss or damage resulting from improper operation...

Page 17: ...Usar s lo un fusible o interruptor de circuito del mismo amperaje que el circuito en el cual est operando el compresor de aire MANUAL DEL OPERADOR PARA COMPRESOR DE AIRE PERMANTEMENTE LUBRICADO PC2053...

Page 18: ...sultar en lesiones menores Este manual contiene informaci n que es importante que usted conozca y comprenda Dicha informaci n se relaciona con la protecci n deSUSEGURIDADPERSONALyLAPREVENCI NDEPROBLEM...

Page 19: ...DE EXPLOSI N O INCENDIO TANQUE DE AIRE LAS SIGUIENTES CONDICIONES PUEDEN DETERMINAR EL DEBILITAMIENTO DEL TANQUE Y ORIGINAR UNA VIOLENTA EXPLOSI N DEL MISMO SIENDO CAUSA DE DA OS A LA PROPIEDAD O LESI...

Page 20: ...L AIRE PROVENIENTE DEL COMPRESOR TANTO DIRECTAMENTEODESDEUNRESPIRADORINSTALADOALCOMPRESOR TRABAJEENUN REACONBUENAVENTILACI NCRUZADA LEAYSIGALAS INSTRUCCIONESDESEGURIDADPROVISTASENELR TULOOENLOSDATOS D...

Page 21: ...OTECTORAS O INTENTE EL MANTENIMIENTO HASTAQUELAUNIDADHAYAALCANZADOSUENFRIAMIENTO QU PUEDE OCURRIR C MOPREVENIRLO UN COMPRESOR PORT TIL PUEDE CAERSE DE LA MESA EL BANCO DE TRABAJOODELTECHODA ANDOALCOMP...

Page 22: ...compresor de aire 4 Almacenar el compresor de aire en un lugar limpio y seco Cuando termine usted de usar el compresor de aire Para lograr la vida til ptima de este compresor de aire la unidad se debe...

Page 23: ...m ticamente cuando la presi n del tanque cae al nivel de la presi n de arranque fijada en la f brica Tambi n apaga el motor cuando la presi n del tanque de aire sube hasta el nivel de corte fijado en...

Page 24: ...AIREDEBECONECTARSE ATIERRAAPROPIADAMENTE Este compresor de aire est equipado con un cord n que tiene un alambre para conectar a tierra y un enchufe adecuado para tierra El enchufe debe conectarse a un...

Page 25: ...EBEEXCEDERLACAPACIDAD M XIMA ESTIPULADA EN LOS MODELOS CON S LOUNAV LVULADEINTERRUPCI N ALUSAR ACCESORIOSCONUNACAPACIDADM XIMAINFE RIORA125PSIG ANTEPONERUNREGULADOR ELAGUADELAIRESECONDENSAR DENTRODELT...

Page 26: ...jabonosa NOSOBREAJUSTAR Unav lvuladechequeodefectuosaproducefugas de aire constantes por la v lvula de alivio de presi n cuando hay presi n en el tanque y el compresor est apagado Retirar y limpiar o...

Page 27: ...mplazar si es necesario Desmontar limpiar o reemplazar Ajustar las conexiones Ver la secci n fugas de aire en la gu a para detecci n de problemas El motor arrancar autom ticamente cuando la presi n de...

Page 28: ...12 SP D23708 SSP 473 CAC 1275 SST 5314 1 SSF 607 AC 0430 CAC 1254 SSP 480 SUDL 403 1 SSW 7480 TIA 4150 SS 1286 CAC 4296 1 AC81 B SSF 621 GA 352 SSP 6021 DAC 4105 2 SSW 7367 SUDL 9 1 LISTA DE REPUESTOS...

Page 29: ...Alivio de tensi n CAC 1275 V lvula de Chequeo SSP 473 Manga de tuerca Pedir juego del interruptor de pressi n SUDL 9 1 Tornillo 8 32 x 375 344 se usan 2 SSP 480 Niple SSW 7367 Vuje de alivio de tensi...

Page 30: ...14 SP D23708 CAC 1212 CAC 1206 1 DAC 269 SSF 3147 AC 0206 AC 0815 AC 0470 SUDL 9 1 D23584 D21919 CAC 1199 CAC 1213 CAC 1213 AC 0471 SSF 3156 SSG 8169 CAC 1196 SSF 995 CAC 4323 DIAGRAMA DEL COMPRESOR...

Page 31: ...Tornillo 3 8 16 Camisa de cilindro D23584 Conjunto de terminaci n de cable AC 0815 Correa de sincronizaci n CAC 1213 Aislador de la bomba se usan 5 x SUDL 9 1 Tornillo 8 32 x 375 344 AC 0471 Cubierta...

Page 32: ...lmacenaje o da os resultantes durante su transporte 4 Desviaci n de las instrucciones operativas especificaciones y programas de mantenimiento 5 Costos de mano de obra p rdida o da os resultantes de u...

Page 33: ...UR D AIR LUBRIFICATION PERMANENTE MOD LE N Un disjoncteur est recommand N utiliser qu un fusible ou disjoncteur qui a la m me valeur nominale que le circuit de d rivation du compresseur d air PC2053 1...

Page 34: ...ou moyennes Ce guide contient des renseignements importants que vous devez bien saisir Cette information porte sur VOTRE S CURIT et sur LA PR VENTION DE PROBL MES D QUIPEMENT Afin de vous aider identi...

Page 35: ...RVOIROUREMPLACERLECOMPRESSEURAUCOMPLET NE JAMAIS PERFORER AVEC UNE PERCEUSE SOUDER OU FAIRE UNE MODIFICATION QUELCONQUE AU R SERVOIR OU SES ACCESSOIRES LE R SERVOIR EST CON U POUR SUBIR DES PRESSIONS...

Page 36: ...ONEDETRAVAIL NE JAMAIS INHALER L AIR MIS PAR LE COMPRESSEUR QUE CE SOIT DIRECTEMENT OU AU MOYEN D UN DISPOSITIF RESPIRATEUR BRANCH AU COMPRESSEUR TRAVAILLER DANS UN ENDROIT O IL Y A UNE BONNE VENTILAT...

Page 37: ...MINUTESAPR SLEURFONCTIONNEMENT NEPASTENTERD ATTEINDRELESCOMPOSANTESDERRI RELESGARDESDE PROTECTIONETNEPASEFFECTUERDEL ENTRETIENAVANTD AVOIRLAISS REFROIDIRL APPAREIL RISQUE PR VENTION UNCOMPRESSEURPORTA...

Page 38: ...evait fonctionner un facteur d utilisation sup rieur 5O le compresseur est trop petit pour les exigences de l emploi et un fonctionnement continu au del du facteur d utilisation de 5O peut constituer...

Page 39: ...enchement tablie R GULATEUR SOUPAPE DE S RET MANOM TRE DE R SERVOIR MANOSTAT MANOM TRE DE SORTIE D AIR ENSEMBLE COMPRESSEUR R SERVOIRD AIR ROBINET DE VIDANGE non illustr CLAPET DE NON RETOUR pas illus...

Page 40: ...une prise appropri e doit tre install e par un lectricien qualifi Lorsduremplacementoudelar parationducordonoude lafiche lefildeterredoit tretenus par desfilsporteurs d lectricit Nebranchezjamaislefi...

Page 41: ...VOIR D AIR CAUSANTUNRISQUEDERUPTUREDU R SERVOIRD AIR REMARQUE Si le bouchon du robinet de purge est bloqu lib rez toute pression d air Puis enlevez le robinet nettoyez le et r installez le UNE TROP FO...

Page 42: ...et nettoyez ou remplacez la soupape de s ret NE SERREZ PAS TROP Ler servoird airdoit treremplac Ner parezpasla fuite Tropfortepression lasoupape de s ret se soul ve Fuite d air aux raccords Fuite d ai...

Page 43: ...nexions lectriques rel ch es Pi ces du moteur internes vaporis es de peinture D fectuosit possible du moteur Fusible saut coupe circuit d clench La soupape de s ret du manostat n a pas lib r la pressi...

Page 44: ...708 SSP 473 CAC 1275 SST 5314 1 SSF 607 AC 0430 CAC 1254 SSP 480 SUDL 403 1 SSW 7480 TIA 4150 SS 1286 CAC 4296 1 AC81 B SSF 621 GA 352 SSP 6021 DAC 4105 2 SSW 7367 SUDL 9 1 PI CES DISPONIBLES POUR CET...

Page 45: ...ension CAC 1275 Soupape de s ret SSP 473 Ens crou manchon 3 8 Commander ensemble du manostat DAC 4105 2 SUDL 9 1 Vis 8 32 x 375 344 2 utilis es SSP 480 Mammelon SSW 7367 Accouplement d all gement de t...

Page 46: ...D23708 CAC 1212 CAC 1206 1 DAC 269 SSF 3147 AC 0206 AC 0815 AC 0470 SUDL 9 1 D23584 D21919 CAC 1199 CAC 1213 CAC 1213 AC 0471 SSF 3156 SSG 8169 CAC 1196 SSF 995 CAC 4323 PI CES DISPONIBLES POUR CET AP...

Page 47: ...8 16 Couvert de cylindre CAC 4130 2 Raccord de connection de c ble AC 0815 Courroie de synchronization CAC 1213 Isolant de la pompe 5 utilis es x SUDL 9 1 Vis 8 32 x 375 344 AC 0471 Coiffe gauche AC 0...

Page 48: ...ages encourus lors du transport 4 Tout cart aux directives d utilisation aux sp cifications et au calendrier d entretien 5 Les frais de main d uvre et toutes pertes ou dommages encourus suite une util...