Summary of Contents for Parani-MSP100

Page 1: ...Sena Technologies Inc All rights reserved by Bluetooth Enabling Wireless Serial Communications Parani MSP100 User Guide Version 1 0 0 2006 08 20 For Wireless Multi Serial Communications based on Blue...

Page 2: ...ATION VIA PARANI MSPSOFTWARE 20 3 1 1 When Parani MSP is connected to PC directly 20 3 1 2 Log in Parani MSP software 21 3 1 2 Operation Mode 22 3 1 3 Bluetooth 29 3 1 4 Connections 30 3 1 5 Neighborh...

Page 3: ...NDS 53 6 AT COMMAND INTERFACE 55 7 CONFIGURATION VIA WEB 59 7 1 MSPCONFIGURATION 59 7 2 MODE CONFIGURATION 61 7 3 IPASSIGNMENT 62 7 4 NETWORK SETTING 63 7 5 RESTORE FACTORY SETTING 64 8 INTERNET ACCES...

Page 4: ...rani MSP has Bluetooth protocol stack qualified by Bluetooth SIG which assures standardized secure and scaleable serial communications Parani MSP identification of data per each additional unique Blue...

Page 5: ...chapter 9 Table 1 1 Parani MSP Model Hardware Interface Specifications Parani MSP100 LAN 10 100 x2 Inclusive Hub function Ethernet RS232C com supported Built in Bluetooth 1 USB A type port for USB ex...

Page 6: ...sible If DIP switch is on the side of drawing Parani MSP communicates with Host via Ethernet line TCP IP If users want to use RS232 com please change the direction of switch to the other way effective...

Page 7: ...ni MSP can be chained without network hub This is for the better user experience of convenient installation Use a straight cable for this purpose USB Extension Port For expanding multi connection beyo...

Page 8: ...ATUS LED ERROR LED Description ON OFF Normal Blinking OFF Connecting to Station MSP in Repeater Mode OFF ON Internal Bluetooth module operation malfunction ON Blinking LAN connection Error Connecting...

Page 9: ...P as RS232 mode RS232 communication with Host you don t need to configure Networking settings RS232 Mode Parani MSP Installation Network Configuration Serial Port Configuration Change of DIP switch Co...

Page 10: ...HyperTerminal screen If Parani MSP prompts Login ID password default values are Login admin Password 11111 6 Default Parani MSP IP address factory setting is 192 168 1 10 Revise to user appropriate n...

Page 11: ...All rights reserved 9 If No 1 Static IP is selected the following is displayed on screen 10 Enter user Static IP address In the example below 192 168 0 3 is entered for the Parani MSP IP address Enter...

Page 12: ...request Enter Y Yes press Enter to reboot Parani MSP to apply the revised Network Settings 13 Enter Login ID and Password Default ID admin Password 11111 14 Revised Network settings are displayed An e...

Page 13: ...Point By direct connection of Parani MSP to ADSL the internet is accessible via Bluetooth Select menu 2 LAP by entering 2 Parani MSP prompts for LAP profile enable disable Select Y Yes to enable or N...

Page 14: ...STATUS and ERROR LEDs flash DO NOT TURN OFF Parani MSP during firmware upgrade Turning off Parani MSP during firmware upgrade may result in irreversible operation malfunction There are two methods of...

Page 15: ...eb site to C folder on your PC and run tftp command on Start Run as below z Users need to make sure that the upgrade ROM file is in the same location or users need to specify the exact location to sen...

Page 16: ...please check the network connection status z Once ROM file is delivered to the connected Parani MSP the upgrade firmware will be recorded to nonvolatile memory During this time both STATUS LED and ERR...

Page 17: ...SP can be used for both Configuration and Data communication For this users need to change the DIP switch of Parani MSP to the right Note Before to configure the serial port settings please change the...

Page 18: ...S CTS Software XOn Off None If you enable AT command interface AT commands which are compatible with Parani SD can be used with Parani MSP Please refer to Parani MSP AT command list in chapter 6 For a...

Page 19: ...ts reserved 2 5 Reset Reboot Quit Entering no 4 Parani MSP RESET in the main menu restores all factory default value settings REBOOT restarts Parani MSP for new configuration application QUIT makes us...

Page 20: ...de to use Parani MSP configuration software will be introduced How to configure via Telnet or Web browser will be introduced in Appendix 3 1 Configuration via Parani MSP software 3 1 1 When Parani MSP...

Page 21: ...ic Parani MSP which has been installed locally or remotely users may use Parani MSP software Start Parani MSP software and press Search MSP device button on the left side Parani MSP installed remotely...

Page 22: ...er UserID Password admin 11111 3 1 2 Operation Mode Parani MSP may be set to different type of Mode so users may select one for its own implementation There are 6 types of Mode Server Client Vertex Re...

Page 23: ...om searching Parani MSP a Server Mode In Sever Mode Parani MSP will operate as a TCP server on the network Host PC will connect to Parani MSP via TCP IP Ethernet and Parani MSP get the connection Afte...

Page 24: ...nection is established new TCP connection will be established as well So when Bluetooth connection is stopped TCP connection would be closed If this behavior annoys your application users may use this...

Page 25: ...t to which Host as they need Server Table has priority over default Host Information Bluetooth device 00 0B 53 20 00 7E will connect to Host 192 168 1 118 port no 5002 Bluetooth device 00 0B 53 20 00...

Page 26: ...ails to connect to Host it will retry Enter the connection retry frequency here Entering 0 zero means no retry c Vertex Mode In Vertex Mode Host and Bluetooth devices communicate each other via Parani...

Page 27: ...ion Status LED of Repeater is blinking Repeater and Bluetooth devices connected to the repeater are displayed in Repeater tab in software e Serial Hub Mode Users may transmit receive data via Parani M...

Page 28: ...o path in the route table Press Add to add route entry Following dialog will appear To select Bluetooth device press then Bluetooth devices connected currently will be displayed in another dialog or e...

Page 29: ...th Parani SD can be used with Parani MSP Please refer Parani MSP AT command list 3 1 3 Bluetooth In this page users can find current status of Parani MSP You can see the process of command at the bott...

Page 30: ...ction status of devices to Parani MSP Now three Bluetooth devices have been connected for Wireless serial communications as below Left square shows quality of connection Green square is good red squar...

Page 31: ...y Names of only ever connected devices will be appeared Otherwise Unknown will be shown instead 3 1 6 Repeater This page shows tree structure how Repeater MSP and terminal devices are connected to the...

Page 32: ...32 Copyright 2006 Sena Technologies Inc All rights reserved 3 1 7 MSP information Users may see Parani MSP information currently accessing...

Page 33: ...right 2006 Sena Technologies Inc All rights reserved Pressing Log button system log messages will appear in notepad System log is the source of invaluable information when the problems occur during op...

Page 34: ...nnected to Parani MSP corresponding TCP port for the Bluetooth device will wait for connection for as Host The Host may connect to the terminal via this port of Parani MSP Please refer to the drawing...

Page 35: ...t may communicate via Parani MSP same as in Server mode Only difference from Server mode is that the initiator is now Parani MSP Please refer to the drawing below for your better understanding Fig 4 2...

Page 36: ...Bluetooth devices Please refer to the drawing below Multiple Repeater Parani MSPs up to 7 can be connected to one Station Parani MSP but Repeater to Repeater connection Multi level repeater is not all...

Page 37: ...ds to be configured in advance using Parani MSP software In Band Command In addition to Route Table user can specify the destination of the frame they send by inserting extra frame called In Band Comm...

Page 38: ...ode Parani MSP will send data to external serial port not via Ethernet network In RS232 mode Parani MSP handles data in Multi drop way so data written to RS232 interface of Parani MSP will be delivere...

Page 39: ...e the Console switch to data mode Changes will be effective after power cycling of Parani MSP Please restart Parani MSP AT Commands AT command is very familiar with the legacy serial application devel...

Page 40: ...40 Copyright 2006 Sena Technologies Inc All rights reserved Please refer to AT command List for its usage...

Page 41: ...ves users insight how each commands work Using control TCP port users can make their own application control Parani MSP by themselves This means users do not need to equip expensive Bluetooth developm...

Page 42: ...ies Inc All rights reserved Fig 2 1 1 PuTTY Press Open then following telnet session will be opened Enter user admin and pass 11111 to access Parani MSP via Control Commands Every command responds wit...

Page 43: ...quit the communication with Parani MSP Ex QUIT OK Disconnected MODE server client vertex hub repeater rs232 To check or change the current Operation MODE of Parani MSP If any of Bluetooth devices are...

Page 44: ...Ex BIND 00 0B 53 00 00 01 8000 OK BIND Parani SD 8001 OK BIND 0 00 0B 53 00 00 01 8000 1 Parani SD 8000 OK RELE port no If users do not need to use a bound port number RELE command can be used to rele...

Page 45: ...ection Below example means when there is no communication for 10 min Parani MSP will send beacon packets 3 times by 10 seconds interval Ex KATO 600 3 10 OK KATO 600 3 10 5 3 Commands for Client Mode S...

Page 46: ...T on off In Client mode in the event of TCP disconnection Parani MSP automatically attempts to recover TCP connection when PSIST is set to ON in the period of pre defined ms by REPT command Ex PSIST O...

Page 47: ...STATION bdaddr To configure Bluetooth address of station Parani MSP In repeater mode Parani MSP will try to connect to this device Ex STATION 00 0B 53 00 00 01 OK REPEATER Display all of repeaters an...

Page 48: ...bytes ASCII code only Ex PIN 1234 OK SECU low high SECU command revises the security level Low obtains no security High obtains Enabling Security Default SECU displays current security level Ex SECU h...

Page 49: ...s on System Log you should turn this option on Ex TEMPKEY on OK TEMPKEY OK on SCAN inquiry page noscan For Parani MSP scan mode assignment INQUIRY set to ON activates discoverable mode PAGE set to ON...

Page 50: ...us Zero rssi means the most efficient RF condition so called Golden Range With link quality lower than 200 throughput may be affected or link may be lost Response idx dev_id port bdaddr name tx_byte r...

Page 51: ...max connections To assign maximum Bluetooth devices concurrently connectable to Parani MSP Default value is 7 Each additional USB extension module adds up to 7 more Parani MSP connectable Bluetooth de...

Page 52: ...a terminal is sent from Parani MSP prior to any data transmission when TCP socket connected It consists of Bluetooth address and name in fixed length with NULL padding following Available in server mo...

Page 53: ...2 timestamp 4 data length timestamp in milliseconds Ex DUMP line 0 len 4 timestamp 1413986 61 62 63 64 abcd line 0 len 4 timestamp 1414056 4F 4B 0D 0A OK OK LOG line LOG displays system logs If line...

Page 54: ...igns new control port number Revised control port number is effective after Parani MSP restart Default CTRL displays current control port number value Ex CTRL 3500 OK CANCEL To cancel current backgrou...

Page 55: ...e appended for Parani MSP exclusive use Supported AT commands and their differences from AT command of Parani SD are summarized as below Please refer to Parani SD userguide for more information Comman...

Page 56: ...ODE Support only Mode 1 and Mode 2 You can register Mode 1 devices by using AT BTREG S registers are not supported Following commands are appended to Parani MSP Command Description Example AT BTCHAN S...

Page 57: ...m non selected Parani SD is buffered on Parani MSP and retrieved when corresponding Parani SD is selected by ATO command If link is lost with currently selected device one of connected devices will be...

Page 58: ...000B53000001 connected to 000b53000001 OK ATO CONNECT 000B53000001 OK ATD000B53000002 making new connection to 000B53000002 OK while connected with 000B53000001 CONNECT 000b53000002 connected and rout...

Page 59: ...rani MSP configure manage and current status check functions To access Parani MSP via Web interface open user web browser and enter the Parani MSP IP address in the address area Here is shown the 192...

Page 60: ...ity set Pairable option to UNCHECKED enabling High Security When this option is NOT checked other Bluetooth devices except those that already share link key with Parani MSP cannot connect to Parani MS...

Page 61: ...Parani MSP Server mode default port configuration 2 List For assessment of currently connected Bluetooth devices 3 Bdaddr btname Enter address or preferred name of Bluetooth device s to BIND 4 Port no...

Page 62: ...to Host enter the connection retry frequency Entering 0 zero obtains retry abort 4 re connect automatically if link is lost For Host connect retry if failed Retry frequency is set in the preceding fun...

Page 63: ...ooth devices 7 4 Network Setting For user Parani MSP network setting 1 use DHCP When checked Parani MSP receives IP address from DHCP server 2 IP address Network mask Gateway DNS Enter appropriate dat...

Page 64: ...64 Copyright 2006 Sena Technologies Inc All rights reserved 7 5 Restore Factory Setting To reset to Parani MSP default factory settings click the Restore button...

Page 65: ...operate as conventional Bluetooth AP to provide Bluetooth devices Internet connectivity Following 3 standard ways of Bluetooth internet connections are supported 8 1 LAP 8 2 PAN 8 3 Dial Up Modem Emu...

Page 66: ...provides virtual COM port which is redirected to TCP socket connection to Parani MSP SENA provides licensed Serial IP programs to customers purchasing Parani MSP since July 2005 Users who purchased P...

Page 67: ...Serial IP icon on the right side of the Windows Tray activates Configure Trace Window and Port Monitor menu display Fig 9 3 Windows Tray after installation of Serial IP Click Configure menu and select...

Page 68: ...reserved Fig 9 4 COM port configuration Parani MSP is ready for use without revising Serial Port Applications Connect Parani SD to Parani MSP and see if data channel established between Parani SD and...

Page 69: ...can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Inc...

Page 70: ...Magic Number 4bytes Item1 Item2 Item8 Item len parameter Item list Item length Parameter Example 0x01 Var Product Name PARANI MSP 0x02 Var Model Code 101 0x03 Var Product Serial Number MSP030403287 0x...

Page 71: ...es Inc All rights reserved An Example 0 8 16 24 32 Magic1 FAh Magic2 05h Magic3 21h Magic4 EFh Item1 01h Len1 09h P R O M I M S P Item2 02h Len2 03h 1 0 1 Item3 03h Len3 0Ch M S P 0 3 0 4 0 3 2 8 7 It...