C.31. S59: Current Slave in Communication (default 0)
This value shows the current slave number in communication. The value is automatically stored when
the slave is selected for communication. This value can also be set by user so the master unit
connects to a specific slave to connect first in case the master unit reboots. The value range is 0~4. 0
means the maser unit never connected to a slave. The master will connect to a slave whatever
responses first.
C.32. S60: Reconnect Time Interval (default 5)
This value defines reconnect time interval in case a slave is disconnected in multiple connection mode.
The actual reconnect time interval will be the value multiplied by two in seconds. For example, if the
value is set to 5, the reconnect time interval will be 10 seconds. The value should be greater than or
equal to 5. The master unit will only try to reconnect when its mode is set to Mode1.