- 9 dBm (0xF7) to +22 dBm(0x16) by step of 1 dB if the High Power PA is selected
For
TxPower
> +15 dBm, the user must select the VBAT supply for the PA using the
SetPaConfig
command.
•
RampTime
defines the PA power ramping time. The Ramp Time can be set from 10 us to 3400 us according to the
following table:
A value of Ramp Time value of 40 us allows the best trade-off between a fast RF power establishment and the minimum RF
spurious, therefore a compliance to the radio standards.
Table 9-6: RampTime
RampTime
Value
Ramp Time in us
SET_RAMP_10U
0x00
10
SET_RAMP_20U
0x01
20
SET_RAMP_40U
0x02
40
SET_RAMP_80U
0x03
80
SET_RAMP_200U
0x04
200
SET_RAMP_800U
0x05
800
SET_RAMP_1700U
0x06
1700
SET_RAMP_3400U
0x07
3400