background image

Selmo s.n.c.

Via Pacinotti, 24 - 35030 Rubano Padova - Italy
Te

l. +39.049.897.6761 -Fax.+39.049.897.6085

T

S

ECHNICAL

PECIFICATIONS

Product

Digital electronic control for towel radiators

Applications

Towel radiators

Version

Class II, Class I

IP Level

IP44

Fil-Pilote

Available for Class II

Room temperature

setting

Digital

Selectable temperature range

+7°C ÷ +32°C

Operational temperature

-10°C ÷ +40°C

Maximum power

2000w

Supply voltage

230VAC 50Hz

Size

131 x 76 x 42mm (HxLxl)

Connection to the heating element

3 faston connectors 6.3x0.8 mm: ground (Class I only), neutral,

Temperature sensor

10KOhm a 25°C, type: NTC

Warranty

2 years

Standard

-EN 60335-1:2012 -EN 60335-2-30:2011 -EN 60335-2-43:2008 -EN
61000-3-2:2004 -EN 61000-3-3:1995
-EN 55014-2:1998 -EN 55014-1:2008 -EN 50366:2003

Approval mark

CE

Plastic box

ABS-V0

Environment directives

WEE,RoHS

Electromagnetic compatibility

89/336/EEC

Function

Comfort, Night, Antifreeze, Fil-pilote, Boost, Chrono, Stand-by.
Eco Wi-Fi open window detection.

Display

Led display

Available Colours

White, Chrome

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

Synthesis Plus

cronothermostat for towel rail

EN

Comfort technology division

Selmo

Rev. 01- Sept. 2017

Summary of Contents for Synthesis Plus

Page 1: ...ons provided in the model the radio module is offered to work interactively to an integrated Wi Fi system for iOS and Android systems which with the appropriate App allow to simplify further and greater the programming phase and the management Synthesis Plus is a certified product Synthesis Plus is compliant with the directives Eco design Directive for Energy using Products 2005 32 EC 0 5W EN 6033...

Page 2: ...I only neutral Temperature sensor 10KOhm a 25 C type NTC Warranty 2 years Standard EN 60335 1 2012 EN 60335 2 30 2011 EN 60335 2 43 2008 EN 61000 3 2 2004 EN 61000 3 3 1995 EN 55014 2 1998 EN 55014 1 2008 EN 50366 2003 Approval mark CE Plastic box ABS V0 Environment directives WEE RoHS Electromagnetic compatibility 89 336 EEC Function Comfort Night Antifreeze Fil pilote Boost Chrono Stand by Eco W...

Page 3: ...using carefully ensure that the line voltage is the same as that specified for the device see technical specifications Only use heating elements compatible with the type of used towel radiator Disconnect the power supply before cleaning or maintenance In case of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be replaced exclusive...

Page 4: ...ve Longer connectors could damage the device CLEANING Disconnect the device from the power network before cleaning or servicing Use only delicate non abrasive detergents WARNING Disconnect the power supply before proceeding with installation The installation has to be performed only by authorized personnel WARNING Disconnect the power supply before proceeding with installation The installation has...

Page 5: ...e device has to be protected by a 30mAcircuit breaker RCD 10 Power the device with the recommended voltage see technical specifications 11 For models having no plug it is necessary to install a suitable omnipolar disconnection switch ensuring complete disconnection in case of category III overvoltage that means a switch with at least 3 mm of space between open contacts 12 After ensuring that the O...

Page 6: ...the yellow green wire has to be connected to the ground Connection to the Fil Pilote system Only for product versions equipped with Fil Pilote 1 PHASE NEUTRO PHASE NEUTRO Living room Bathroom Bedroom 1 Bedroom 2 Thermostat class 2 Thermostat class 2 Thermostat class 2 Thermostat class 1 Switch Station Fil pilote Switch Switch Switch Thermostat Thermostat Thermostat Thermostat Example Fil pilote Se...

Page 7: ... C when a Comfort temperature is set below the Night temperature the system automatically regulates the Night temperature to the same value of the Comfort temperature Mode Crono Mode Antifreeze Mode Night Mode Comfort Mode Fil pilote Button Button Mode Button Active Heating Element Symbol Key lock symbol Active eco function symbol Open window detection Symbol Wifi active Symbol only in versions wh...

Page 8: ...ature stops blinking ANTIFREEZE MODE In Antifreeze mode the temperature is fixed to 7 C The device activates the heating element when the room temperature falls below 7 C It is suggested to set this operating mode when the room is not occupied for several days Press the Mode button until the display shows the Antifreeze icon BOOST MODE The Boost mode can be used to quickly warm up the room Press t...

Page 9: ... stops blinking If Fil Pilote is not installed the default mode of operation is Comfort O W D PEN INDOW ETECTION FUNCTION This enables detecting of an open window by sensing a sudden decrease of the temperature in the room In such a case the device deactivates the heating element for 30 minutes at which point the radiator will resume to operate in the previously set state When the function is acti...

Page 10: ... can be programmed by the user To activate the chrono function Press the Mode key until Chrono mode icon appears on the display For the description and how to use the function refer to the instructions on the remote control ECO 6 DATE AND TIME PROGRAMMING Press to activate the stand by mode button On Stand by Press the and buttons simultaneously to menu access Press the or buttons until the TIM Ti...

Page 11: ...ion of natural resources This symbol applied to the product indicates the obligation to deliver to a special collection center to be disposed of in accordance with Directive 2002 96 EC WEEE Symbol Active heating element When the symbol is on the heating element is working and the towel warmer is heating WARNING In case of failure of the temperature sensor the word ALL is displayed on the display t...