background image

Fil-Pilote Comfort Night Antifreeze

Chrono

ECO

Adaptive starting

control

Open window

system

Key lock

ASC

2. “COMFORT”

“NIGHT” MODES

AND

Two different levels of temperature can be set:
-"COMFORT" temperature: It is the temperature used for "Chrono", " Fill pilot" and "Comfort" modes.
-"NIGHT" temperature: It is the temperature used for the "Night" and "Chrono" modes.
The desired temperature can be set pressing the [+]

[-] buttons. The range of configurable temperature is

or

7°C- 32°C.
IMPORTANT!
The temperature of "Night" mode must be below to the “Comfort” mode temperature. For this reason, the “Night”
mode temperature can be set to a value between 7°C and the "Comfort" mode temperature.
The "Comfort" temperature can be set throughout the range of 7 ° C to 32 ° C. If "Comfort" temperature is set
below "Night", the latter is set equal to the first

3. THERMOSTAT FUNCTIONS AND MODES

An icon on the display indicates the current operating mode (see table).

Mod Fil-Pilot

e

e

It is the mode in which the radiator is controlled by a remote-control unit.
1. Press the [mode] button until the "Fill-Pilot" icon is displayed.
2. Set the desired temperature through the [+] and [-]
The mode of operation will be selected by the Fil-Pilot Control Center.

The device operates with the most advanced "Fil-Pilot" system with six commands, which
allows the following functions:

Standby: power off the heating element, the device remains active.
Comfort: maintains the "Comfort" temperature set by the user.
Eco: maintains the room temperature 3,5°C below the "Comfort" temperature.
Anti-freeze: maintains the room temperature at 7°C.
Eco-1: maintains the room temperature 1°C below the "Comfort" temperature.
Eco-2: maintains the room temperature 2°C below the "Comfort" temperature.

Comfort Mode

It is the normal use of the radiator to maintain the room temperature to the set value.
1. Press the

button until the corresponding icon appears on the display.

[mode]

2. Select the desired temperature with the

and

buttons.

[+]

[-]

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

Rev.02 - June 2018

“Infinity PLUS”

Electronic control for electric radiators

Comfort technology division

Selmo

EN

Summary of Contents for Infinity PLUS

Page 1: ...it to interface with the Selmo remote control Infinity is a certified product Infinity is according to direcrives Eco design Directive for Energy using Products 2005 32 EC 0 5W EN 60335 1 2012 A11 201...

Page 2: ...ck ASC IR receiver 7 32 C 2000W 230Vac 50Hz 3 cables Neutral Grey Phase Brown Fil Pilote Black 2 cables Neutral Blue Phase Brown Plug Schuko Switzerland Italian English 2 female faston 6 3x08mm phase...

Page 3: ...I If installed in rooms with bath or shower observe the protection zones in the United Kingdom according to the regulation for IEE wiring Also observe all local regulations must be protected by a 30mA...

Page 4: ...stor only by personnel authorized Make sure that the heating element power does not exceed the power maximum required by the thermostat ATTENTION Disconnect the power supply before installation The in...

Page 5: ...e respective housing of the thermostat 4 Push the cables into their housing in order to ensure correct fixing 5 Apply the plastic cover 6 do not rotate the device for more than 30 in both directions S...

Page 6: ...that supports the Fil Pilote system The brown wire is the phase L the gray wire is the neutral N and the black wire is used for the reception of the Fil Pilote signal DO NOT connect the black wire to...

Page 7: ...switched on it emits a sound lasting one second Mode Stand By Crono Antifreeze Night Comfort Fil Pilote Mode Current week day Crono mode daily program Crono mode selected program Setted hour or tempe...

Page 8: ...unit 1 Press the mode button until the Fill Pilot icon is displayed 2 Set the desired temperature through the and The mode of operation will be selected by the Fil Pilot Control Center The device ope...

Page 9: ...lic space To turn on off the keypad press the button for 5 seconds mode Adaptive Starting ControlASC This function if activated will turn on the radiator in advance of the programmed Max 2 hours to en...

Page 10: ...and confirm with the mode button Minute Use the and buttons to select the minutes and confirm with the mode button When finished the thermostat will exit the programming menu b Set programs for the C...

Page 11: ...nt for the recycling of electrical and electronic equipment Separate collection and recycling of the equipment at the time of disposal promotes the conservation of natural resources and ensures that i...

Reviews: