![SellEton Scales SL-7561 User Manual Download Page 18](http://html1.mh-extra.com/html/selleton-scales/sl-7561/sl-7561_user-manual_1237069018.webp)
16
COMMUNICATION SETTINGS
Format 1 [CP - 1]
Workable with a PC
RS232COM serial interface can receive simple ASCII command.
RS232 parameter:9600Bit/S Baud rate,8 digits,no check point,1 stop.
,
,
CR LF
{
{
{
S 1 S 2 S 3
Data
S 4
S1:
weight status, ST=standstill, US=not standstill, OL=overload
S2:
weight mode, GS=gross mode, NT=net mode
S3:
weight of positive and negative, “+” or “-”
S4:
“kg” or “lb”
Data: weight value, including decimal point
CR:
carriage return
LF:
line feed
Format 2 [CP - 2]
Workable with second display from Yaohua, Baud rate 600.
Format 3 [CP - 3]