Page 1: ...www selletonscales com SL 7561 INDICATOR USER S MANUAL Portable Static Weighing Indicator...
Page 2: ...rameters 2 Specifications 3 Power Supply 3 Displays 4 Display and Key Descriptions 5 Operating Instructions 6 7 Calibration 8 Indicator Parameter Settings Weighing Printing Mode Print Format Connector...
Page 3: ...s it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the samples if possible Another solution to the probl...
Page 4: ...entage of the total weight Manual and automatic printing modes Date and time can be set easily Can connect to a PC or printer for data logging Wireless capability optional Splash proof keyboard and di...
Page 5: ...prevent damage to your indicator When you use the internal battery for the first time you should charge the battery fully to prevent low voltage resulted from self leakage of battery If the battery is...
Page 6: ...4 SL 7561 DISPLAY...
Page 7: ...1 Print data 2 Works with the switch button to enter the calibration menu Total Shows you are in Accumulation mode The scale is at zero The scale is stable Net Shows you are in Net weight mode without...
Page 8: ...o see the current change in weight not the entire amount of weight that is on the scale When the indicator is in normal gross mode pressing the TARE key will Tare the current weight on the scale and e...
Page 9: ...tween the total weight and each individual pad scale weight Individual pad display shows the percentage of that pads load of the total weight Print If the weight on the scale is stable press the PRINT...
Page 10: ...rameter if no errors 10 The display will show SPAN 0 use the STORE key to change to SPAN 1 press the PRINT key to select and enter the calibration setting 11 Use the arrow keys to enter the weight of...
Page 11: ...save and exit settings at any time F 1 Menu Setting working mode unit decimal graduation and capacity Step Parameter Display Settings Options Enter F1 Menu F 1 1 Mode Mode 2 Choose how many weighing...
Page 12: ...move on to the Saving parameter Select 1 and press print to save your calibration settings 9 Save SAVE 0 0 do not save calibration 1 save calibration F 3 Menu Step Parameter Display Settings Options E...
Page 13: ...Menu Step Parameter Display Settings Options Enter F4 Menu F 4 22 Records S 0560 Set how many records weights you want your indicator to store Max the indicator can store is 2000 cps 23 PCB HE 1 0A P...
Page 14: ...ing pads connected to the indicator to weigh an airplane 1 The pads should connect with LFW LRW RRW interfaces 2 Parameter settings F1 Working Mode setting 3 ModE 3 F3 Printing Format setting 1 PF 1 3...
Page 15: ...2 F3 Printing Mode setting 0 PM 0 F3 Axle Number setting 3 ALE 03 3 Measure spacing between tire sets in an axle and place weighing pads accordingly 4 Drive the first axle of the truck on the weighing...
Page 16: ...xle1 842 5kg RRW 293 0kg Axle1 842 5kg Operator Axle2 612 0kg LRW 319 0kg Gross 842 5kg RRW 293 0kg Operator Gross 1041 0kg Axle2 612 0kg Operator Gross 1454 5kg Operator Accumulative Printing Format...
Page 17: ...icator will not function properly Please use the following table to connect your pads correctly INNER TERMINAL BLOCK CONNECTION DIAGRAM Weighing Pad Load Cell Connection Weighing Mode 1 LFW Mode 1 Set...
Page 18: ...LF S 1 S 2 S 3 Data S 4 S1 weight status ST standstill US not standstill OL overload S2 weight mode GS gross mode NT net mode S3 weight of positive and negative or S4 kg or lb Data weight value includ...
Page 19: ...place lid To Replace Paper Remove lid then squeeze and pull forward on the pull tabs to pull printer forward from indicator Carefully remove ink cartridge If the paper roll is not empty use the feed b...
Page 20: ...RR5 EEPROM Error Change PCB ERR6 Exceed Zero Range See Q A section ERR10 Scale was not stable when Zeroed Wait for the scale to stabilize before zeroing ERR11 Zero function can not be used in Tare mod...