21
Remote Display Continuous Sending Mode (C18=1)
For use with a Scoreboard/Remote Display
Note: Baud Rate must be set to 1200 (C19 = 0)
Output Continuous Format
S
T
X
S
W
A
S
W
B
S
W
C
X
X
X
X
X
X
X
X
X
X
X
X
C
R
C
K
S
1
2
3
4
5
6
State A
Bits0,1,2
0
1
2
Decimal point position
1
0
0
XXXXXX0
0
1
0
XXXXXXX
1
1
0
XXXXX.X
0
0
1
XXXX.XX
1
0
1
XXX.XXX
Bits3,4
Division
0
1
X1
1
0
X2
State B
BitsS
function
Bits0
gross=0, net=1
Bits1
Symbol: positive=0, negative=1
Bits2
Overload (or under zero)=1
Bits3
dynamic=1
Bits4
unit: lb=0, kg=1
Bits5
Constant 1
Bits6
Constant 0
State C
Bit2
Bit1
Bit0
unit
0
0
0
Kg or lb
0
0
1
g
0
1
0
t
Bit 3
printing=1
Bit 4
Extend display=1
Bit 5
Constant 1
Bit 6
Constant 0