Bedienungsanleitung SDT43
BDA Serie SDT43 (Stand Jan. 2018)
Seite 43
2.
The Save icon will be displayed to indicate that the setting is saved.
The following
pages describe
the setting
for each type of
linearization.
LINEARIZATION HORIZONTAL TANK (WITH FLAT END)
1.
Navigate to
Hor. Tank
. with the navigation button, and push to confirm.
2.
Two choices appear on the screen:
Input
and
Simulate
3.
Select
Input
, and push to confirm.
4.
Six choices appear on the screen:
Display
Drawing
Explanation
Length
L
The length of the tank
Height 1
H1
The height of the tank
Height 2
H2
The diameter of the tank
(with a cylindrical tank, this is equal to the height of the tank)
Height 3
H3
The height till the topside of the diaphragm (or weld-on nipple)
Height 4
H4
Value must be 0
Fill Height
FH
The maximum percentage of filling of the tank
5.
Fill in each value except Height 4, and confirm each selection with the control button. The
values must be entered in meters.
6.
Select
to save the setting.
7.
The transmitter will return to the main menu.
SIMULATION
After linearization is entered and stored, it is possible to perform a simulation based on the
entered value’s. Based on the value entered in mWc, the transmitter will display the number of
hectoliters (on the basis of the specified linearization values).
6.
Navigate to program point
1.11 – TANK LIN,
and push the navigation button to enter the
menu.
7.
Navigate to
Hor. Tank
. with the navigation button, and push to confirm.
8.
Two choices appear on the screen:
Input
and
Simulate
9.
Select
Simulate
, and push to confirm.
10.
Fill in the desired value based on mWc, the number of hectoliters change directly with a
change in the value mWc.