Demand Start Adjust LED (5) (green) ON 

Low Volts Adjust LED (5) (green) FLASHING 

It is sometimes necessary to adjust the demand start sensitivity to overcome 
what is called “Phantom Loads”. A phantom load is a load that tricks the 
inverter into thinking it should be ON instead of in SLEEP mode. 

To avoid total discharging of your battery the LD450-12 shuts down at a pre-
set low voltage. As all batteries are different, so too is the minimum voltage 
they should be discharged to. The LD450-12 will leave the factory with a 
setting of    

11.0 volts

, change this setting if required. 

The wiring of a house or a portable stereo system in standby are good 
examples of a phantom load. These loads serve no purpose but yet can 
increase battery drain by bringing the inverter ON. Hold the Mode button (7) 
down until LED (5) comes ON, (approximately 1 second) indicating you are 
ready to adjust this setting. The LD450-12 will leave the factory with a setting 
of 4 watts. Now press the Mode button (7) until the desired value is sought. 
LEDs (1) – (4) will return to Status after 20 seconds. 

Hold the Mode button (7) down until LED (5) is FLASHING, (approximately 
2 seconds) indicating you are ready to adjust this setting. Now press the Mode 
button (7) until the desired value is sought. LEDs (1) – (4) will return to 
Status after 20 seconds. 

Low Volts 
Cut-out 

LED 1 

LED 2 

LED 3 

LED 4 

10.0 Volts 
10.1 Volts 
10.2 Volts 
10.3 Volts 
10.4 Volts 

 
 
 
 

 
 
 
 

 
Slow Flash 
Medium Flash 
Fast Flash 
Fastest Flash 

ON 
ON 
ON 
ON 
ON 

10.5 Volts 
10.6 Volts 
10.7 Volts 
10.8 Volts 
10.9 Volts 

 
 
 
 

 
Slow Flash 
Medium Flash 
Fast Flash  
Fastest Flash 

ON 
ON 
ON 
ON 
ON 

 

11.0 Volts 
11.1 Volts 
11.2 Volts 
11.3 Volts 
11.4 Volts 

 
Slow Flash 
Medium Flash 
Fast Flash  
Fastest Flash 

ON 
ON 
ON 
ON 
ON 

 

 

11.5 Volts

 

   

 

ON 

 

Demand Start 
Watts 

LED 1 

LED 2 

LED 3 

LED 4 

4 Watts 
5 Watts 
6 Watts 
7 Watts 

 
 
 
 

 
 
 
 

 
Slow Flash 
Medium Flash 
Fast Flash 

ON 
ON 
ON 
ON 

8 Watts 
9 Watts 
10 Watts 
11 Watts 

 
 
 
 

 
Slow Flash 
Medium Flash 
Fast Flash  

ON 
ON 
ON 
ON 

 

12 Watts 
13 Watts 
14 Watts 
15 Watts 

 
Slow Flash 
Medium Flash 
Fast Flash  

ON 
ON 
ON 
ON  

16 Watts 
Continuous 

ON 
ON 

 
ON 

 
ON 

 
ON 

 

 

 

 

After “11.5 Volts”, the next button press “rolls back” the Low DC Volts 
Cut-out setting to “10.0 Volts” 

After “continuous”, the next button press “rolls back” the demand start 
setting to 4 Watts 

LD450-12 Manual 

Selectronic Australia

 

LD450-12 Manual 

Selectronic Australia

 

10

Summary of Contents for LD450-12

Page 1: ...o Introduction 1 Warranty Card 1 Installation 1 Batteries and Connections 4 Getting Started Quickly 6 Parts Identification 6 Operation 7 STATUS Indicators 7 Demand Start Setting 9 Low Voltage Shutdown Setting 10 Maintenance 11 Inverter 11 Batteries 11 Handy Hint 12 Radio Frequency Interference 13 Fault Finding 14 Product Warranty Conditions 15 Specifications 16 Selectronic Service Network Back Cov...

Page 2: ... card please feel free to drop us a line Yes constructive criticism will also be welcome Installation A system fuse of at least 45 Amps should be placed before the battery An HRC motor start type is recommended See your system designer for details 200mm 200mm 200mm LD450 12 Inverter Front 200mm LD450 12 Inverter Warning As a matter of safety Selectronic strongly recommend that all fixed installati...

Page 3: ...ry this figure will generally be stated at a particular hour rate This is how a deep cycle or storage battery would normally be rated Start Battery By incorporating an auxiliary battery in the manner above the starting battery should remain charged for vehicle starting see your auto electrician The LD450 12 has sufficient battery cable length to allow it to sit underneath the vehicle whilst in use...

Page 4: ... to flash If no LEDs light check for correct connection to battery 10 Turn power point 8 on How long will my battery last 11 You re away To work out how long your battery will last follow this basic guide LD450 12 Parts Identification This guide presumes commencing with a fully charged battery Take the total rating of the appliance being run 1 light globe 25watts 1 20 inch TV 67watts 1 VCR 30watts...

Page 5: ...rom the inverter so it has gone to SLEEP to save power If no power is used within 12 minutes the LED 1 will flash at a slower rate therefore saving more power LED 3 will continue to flash until the battery volts have risen sufficiently In this case charge the battery by starting the vehicle or using a battery charger The low voltage point that the inverter will cut out is adjustable to suit your p...

Page 6: ...econds Hold the Mode button 7 down until LED 5 is FLASHING approximately 2 seconds indicating you are ready to adjust this setting Now press the Mode button 7 until the desired value is sought LEDs 1 4 will return to Status after 20 seconds Low Volts Cut out LED 1 LED 2 LED 3 LED 4 10 0 Volts 10 1 Volts 10 2 Volts 10 3 Volts 10 4 Volts Slow Flash Medium Flash Fast Flash Fastest Flash ON ON ON ON O...

Page 7: ...he inverter s operation by flashing when the inverter is in SLEEP mode and remaining ON when the inverter is brought ON by a load Batteries 1 Every week carry out a thorough visual inspection of all battery wiring taking particular note of the condition of inter connections between cells This maintenance should be carried out in conjunction with the battery manufacturers recommended maintenance Sa...

Page 8: ...r be housed at least 15 metres from the home Check again to make sure that there are no appliances left ON the sequentially switch off appliances at the wall and by watching your night light as described in Handy Hint check to see if the LD450 12 returns to pulsing SLEEP mode after a 10 second delay Once you have found the offending appliance increase the sensitivity of the Demand Start see page 1...

Page 9: ...verter Outside Australia New Zealand Product purchased for use outside Australia New Zealand must be returned to Selectronic Australia s Service Centre to enable warranty claims to be processed Freight cost to be borne by the customer No charge will be made for the product return LD450 12 Manual Selectronic Australia 16 Inverter Type Microprocessor control circuit with PWM full bridge power stage ...

Page 10: ...alia 25 Holloway Drive Bayswater Victoria 3153 Australia Ph 03 9762 4822 Fax 03 9762 9646 service selectronic com au Burley TV Service Rainbow Power Company 278 Edmondson Ave 1 Alternative Way Austral Nimbin NSW 2171 NSW 2480 Australia Australia Ph 02 9606 0279 Ph 02 6689 1430 Fax 02 6689 1109 Reid Technology Ltd 3 5 Auburn Street Solar Inverter Services Takapuna 13 Thirteenth Ave North Shore City...

Reviews: