background image

- 24 -

Functional Video

Installation Manual

Functional & Digital Audio/Video Systems

Select Manufacturing Limited

Commissioning/Final Inspection Test Sheet.

Tel: 01206 855800  Fax: 01206 855801

Client Name:

Commissioning Engineer:

Installer Name:

Site Address:

Telephone No.:

Controller
 No.
(      )

Comments

S

ELECT

General System Comments:

Please use reverse

Trades

On

On

On

On

Off

Off

Off

Off

Trades settings

Fl

at

 N

um

be

r.

Li

ne

 N

um

be

r

Ca

ll T

on

e.

Sp

ee

ch

.

Do

or

 O

pe

In

di

ca

to

r

Lo

ck

 R

el

ea

se

Pr

iva

cy

 In

di

ca

to

r

Vi

de

Pi

ct

ur

e

1
2
3
4
5
6
7

12
13
14
15
16

10

9

11

8

Functional Video

Revision 1.8 Date: 10/03/2009

Summary of Contents for Video 16

Page 1: ...ctLine Selectine Select Manufacturing Limited Unit H1 The Seedbed Centre Wyncolls Road Severalls Business Park Colchester Essex CO4 9HT Telephone 44 0 1206 855800 Facsimile 44 0 1206 855801 E mail sales selectman co uk http www selectman co uk Functional Video Functional Video Revision 1 08 Date 10 03 2009 ...

Page 2: ...ring Detail Panel Camera wiring Detail Strobe and Sounder Wiring Detail Emergency Override Switch Wiring Detail DC Fail Secure Door Release Wiring Detail DC Fail Safe Door Release Wiring Detail AC Fail Secure Door Release Wiring Detail PAC Proximity Access Wiring Detail Single and Dual Entrance Panels Amplifier Dual Panel Display and Auxiliary Output Video Monitor Video Distributor and Camera wiri...

Page 3: ...ergency Override Switch Controller to Request To Exit Button PC Link Wiring Detail Power Connection Wiring Detail Battery Connection Wiring Detail System Controller Summary System Default Settings Programming Instructions Example System Settings GMT BSTTime Clock Digital Time Clock System Wiring Colour Codes System Power Specification User Video Monitor Instruction Leaflet Type AM 1202 PID Commiss...

Page 4: ...Functional Video Systems 2 Functional Video Installation Manual Functional Video Revision 1 8 Date 10 03 2009 ...

Page 5: ... PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL ENTER Data Enter Button Indicator FUNCTION Function Switch Data Switch Digital Time Clock DATA LINE 2 LINE 1 LINE 4 LINE 5 LINE 6 LINE 7 LINE 8 LINE 9 LINE 10 LINE 11 LINE 12 LINE 13 LINE 14 LINE 15 LINE...

Page 6: ... 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL ENTER Data Enter Button Indicator FUNCTION Function Switch Data Switch Digital Time Clock DATA LINE 2 LINE 1 LINE 4 LINE 5 LINE 6 LINE 7 LINE 8 LINE 9 LINE 10 LINE 11 LINE 12 LINE 13 LINE 14 LINE 15 LINE 16 1 C 2 6 9 PS PL DL LINE 3 RESET System Reset Button 5 Amp Fuses System Supply ...

Page 7: ...S PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL ENTER Data Enter Button Indicator FUNCTION Function Switch Data Switch Digital Time Clock DATA LINE 2 LINE 1 LINE 4 LINE 5 LINE 6 LINE 7 LINE 8 LINE 9 LINE 10 LINE 11 LINE 12 LINE 13 LINE 14 LINE 15 LINE 16 1 C 2 6 9 PS PL DL LINE 3 RESET System Reset Button 16 Apartment Inputs...

Page 8: ...t 12V 24VAC DC Lock Supply Input 12V 24VAC DC Lock Supply Input 12V 24VAC DC Lock Supply Input 12V 24VAC DC Entrance Panel 2 Buttons 3 4 5 6 7 8 1 2 9 10 11 12 13 14 15 16 Monitor Activation 5 Amp Fuse 18VDC Supply Indicator 18VDC Distributor Supply 12VDC Camera Supply 18 24VDC Monitor Supply 8 12V 12V 0V 0V 9 16 Output To Video Distributors Video Output To Next Controller Digital Panel 2 Input Di...

Page 9: ...LINE 12 LINE 13 LINE 14 LINE 15 LINE 16 ENTER RESET Door Contact Switch Request to Exit Switch Timed Lock Release ac dc PAC TR TR PAC TR TR Video Monitor System Controller 0 0 dc dc 2 Amp Fuses Lock Release Button Privacy Button Privacy On Indicator Door Monitoring Indicator 75 Ohm End of Line Resistor R1 R2 1 C 2 6 9 PS DL PL AMA 1202 BRK Mono AMA 1702 BRK Colour Video Monitor connection plate Mo...

Page 10: ...ystem Video Controller Entrance Panel PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 Brown of White White of Brown Slate of White White of Slate Red of Orange Orange of Red Green of Red Red of Green Brown of Red Red of Brown Black of Blue Blue of Black Black of Orange Orange of Black Green of Black Black of Green Blue of White White of Blue Blue of Red and Red of Blue White of Orange and Orange of...

Page 11: ...lay wiring detail Entrance Panel PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 Brown of White Note See Camera detail White of Brown Slate of White White of Slate Red of Orange Orange of Red Green of Red Red of Green Brown of Red Red of Brown Black of Blue Blue of Black Black of Orange Orange of Black Green of Black Black of Green Blue of White White of Blue Blue of Red and Red of Blue White of Or...

Page 12: ...1 6 CA 9 10 2 PS PL DL Blue of White White of Blue White of Orange and Orange of White White of Green Green of White Brown of White White of Brown System Controller AT PID Telephone Handset 1 C 2 6 9 PS PL DL LINE 1 Lock Release Button Privacy Button Privacy On Indicator Door Monitoring Indicator Entrance Panel DDA Display wiring detail 8 Functional Video Revision 1 9 Date 14 12 2010 1 CC DML SBL ...

Page 13: ...DC Auxiliary Output wiring detail PANEL 1 OV OV OV 12V 12V 12V 12VDC Auxiliary Output 12VDC Auxiliary Output 3Amp Overall Output 12VDC Auxiliary Output System Controller System Controller Emergency Override Switch For Fail Secure SE Lock Releases PANEL 1 RTE T RTE T Green of White White of Green Common 1 Normally Open 4 Normally Closed 2 External Time Clock wiring detail If an on board Digital tim...

Page 14: ...he lock release if you are using the System Controller for lock release power This is to protect the System Controller against back EMF If the locks are being powered by a PAC Controller then use the MOV supplied with the PAC reader DC Fail Safe Lock Release wiring detail System Controller Fail Safe Lock Release DC Door Monitoring Contact If Specified Green of White White of Green IN4007 Diode Req...

Page 15: ... DDA READER DO CLK 0V VCA D1 SIG 10 5 28V Fail Safe 2 second Lock Output System Controller The RED LED s must always be illuminated on both jumpers except on lock release PANEL 1 PAC PAC TR TR PANEL 2 PAC PAC TR TR 0V 12V NO PAC WITH PAC NO PAC WITH PAC NO PAC WITH PAC NO PAC WITH PAC NO PAC WITH PAC NO PAC WITH PAC Both Door Times be programed to 2 seconds Fail Safe even if only one reader is bei...

Page 16: ... SIG GND N C COM N O L L PAC EASIKEY 1000 12VDC Power Supply 123 123 123 123 WITH PAC NO PAC 123 123 123 123 WITH PAC NO PAC 123 123 123 123 WITH PAC NO PAC PAC Easikey 250 P2 P1 L1 L2 Power Lock1 L3 L4 Lock2 Reader1 V1 S1 R1 A1 V1 Reader2 V2 S2 R2 A2 V2 PAC DDA READER DO CLK 0V VCA D1 SIG 10 5 28V PAC DDA READER DO CLK 0V VCA D1 SIG 10 5 28V PAC DDA READER DO CLK 0V VCA D1 SIG 10 5 28V PAC DDA RE...

Page 17: ...2 6 CA R1 R1 V4 V5 V3 10 9 X1 X2 Y1 Y2 Video Monitor wiring detail Distributor Remove all Jumpers on the Distributors except the LAST in line Normally removed during manufacturing TC TC SIG Entrance Panel 1 Camera SCN EARTH EARTH Sig Scn 4 8 12 and 16 Video Distribution Box U1 U2 E U5 U3 U4 Video Distributor R2 R1 Monitor Coax Monitor Coax Monitor Coax Monitor Coax 12 18VDC Distributor Power 1 C 2...

Page 18: ... VOUT Distribution Supply To Riser Controller 4 8 12 and 16 Video Distribution wiring detail U1 U2 E U5 U3 U4 Video Distributor R2 R1 U1 U2 E U5 U3 U4 Video Distributor R2 R1 U1 U2 E U5 U3 U4 Video Distributor R2 R1 U1 U2 E U5 U3 U4 Video Distributor R2 R1 ALL PRE WIRED EARTH CONTINUITY 12A Functional Video Installation Manual Functional Video Revision 1 8 Date 10 03 2009 ...

Page 19: ...Button Common Trades Detail Trades Button Trades Button Request To Exit Timed Request To Exit Timed Lock Release Detail Lock Common DC Fail Safe DC Fail Secure DC PAC Detail PAC Pre wired Lock Release Serial Connection Transmit Receive Common Controller TC TC Note N O Clean Contacts 0V 12V Note 3 Amp 3 x 12VDC Overall Output TX TX B B Trades Clock Secondary Trades Clock Secondary Trades Clock Auxi...

Page 20: ...deo Signal Output to Distributor Video Screen Output to Distributor Video Riser Signal Output Video Riser Screen Output Video Digital Panel Camera Signal Input Video Digital Panel Camera Screen Input Video Functional Panel 2 Camera Signal Input Video Functional Panel 2 Camera Screen Input Video Functional Panel 1 Camera Signal Input Video Functional Panel 1 Camera Screen Input Video Lobby Landing ...

Page 21: ...d the DATA switches to select the number of seconds for the ringing time duration Select the ring time duration using the TIME SELECTION seconds chart See Controller Programming Instruction Repeat for Entrance Panel 2 Use the FUNCTION switches to select Entrance Panel 1 and the DATA switches to select the number of seconds for the call duration time Select the call duration time using the TIME SEL...

Page 22: ... P P P P 1 0 0 E 1 0 0 0 0 0 1 0 0 1 0 0 0 0 1 0 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S 1 0 0 0 0 1 1 0 0 1 0 0 0 1 1 0 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 1 1 0 0 0 0 1 0 1 M M M M M M M M M M M M M M M M M M M M M M M M 0 1 0 0 0 1 0 1 1 0 0 0 0 0 1 1 1 1 1 1 2 2 2 2 2 2 3 3 4 Door Alarm Duration Time Entrance Panel 2 M M M M M M M M 0 1 0 0 0 0...

Page 23: ... Entrance Panel 1 Continuous 4 1 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 Door Alarm duration Time Entrance Panel 2 15 M inutes 4 0 1 0 0 0 0 1 1 1 1 1 1 1 1 0 0 Note 1 ON X Any Position 1 If an Extension Sounder or Strobe are required set Data switch 8 to ON 0 OFF S Seconds 2 Do not set a value of zero seconds or the system will not time out L Line Number Telephone M M inutes 3 Set all Data switches to the ...

Page 24: ...l operation press the Change Button The output status will change and indicate override is in operation by flashing Programming Only two setting buttons are required and Change Program In normal usethe Change Buttonis used to switch ON or OFF overriding the time switch until the next program ON or OFF time During programming the Change Buttonis used to set the Hours and Minutes TheProgram Button i...

Page 25: ...hanges to show the relay state and the day of the week for a few moments The right hand 8 digits shows the time in HH MM 24 hour format The colon flashes to show the clock is running The last digit shows either 06 03 02 17 11 S DATE 06 03 02 TIME 17 12 56 Display shows Using the Green and Grey buttons as previously set the display to the correct time 24 hour clock Note The time entered is always n...

Page 26: ...s Switch Contact Switch Contact System Wiring Colour Codes System Controllers to Functional and Landing Entrance Panels Controller 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CC TR TR Note The CC connection on the Controller to the Entrance Panel button common should always be a pair I e Slate of Red and Red of Slate Controller to Entrance Panel Amplifier Controller 1 2 Controller to Dual and Landing E...

Page 27: ... the second colour stated above Therefore a wire stated as Black of Slate would be a Black main colour with a Slate banding Lock Release Fail Safe DC Lock Release Connection Lock Release Connection Lock Release Fail Secure DC Lock Release Connection Lock Release Connection Request To Exit Button Timed Switch Contact Normally Open Contacts Switch Contact Normally Open Contacts 21 Functional Video I...

Page 28: ...positions that can be selected in various combinations to achieve varying system functions Available Functions Description Default settings for all functions Setting line number for apartment Serial link set up Medium Volume Electronic Call Privacy Time Strobe Entrance Door 1 Adjustable Time Functions Lock Release time Telephone Ringing time System active duration time Door Open Alarm delay time D...

Page 29: ...n button you will activate the system timer and illuminate the Privacy On indicator stopping all incoming calls for a timed period You can at any time if you wish cancel the timed Privacy period by pressing the Privacy Off On Button This cancellation will be confirmed by the extinguishing of the Privacy On indicator To Adjust Call Volume Rotate the Call Volume Adjuster clockwise to decease the cal...

Page 30: ...ent Name Commissioning Engineer Installer Name Site Address Telephone No Controller No Comments SELECT General System Comments Please use reverse Trades On On On On Off Off Off Off Trades settings Flat Num ber Line Num ber Call Tone Speech Door Open Indicator Lock Release Privacy Indicator Video Picture 1 2 3 4 5 6 7 12 13 14 15 16 10 9 11 8 Functional Video Revision 1 8 Date 10 03 2009 ...

Reviews: