background image

Economy functional & digital audio access systems

Video 8 & 16 

Digital 

Installation Manual

07/06/2002

S

electLine

S

elect

 ine

Select Manufacturing Limited

Unit H1 - The Seedbed Centre - Wyncolls Road - Severalls Business Park - Colchester - Essex CO4 9HT

Tel44(0)1206 855800 - Fac44(0)1206 855801

E-mail [email protected] - http:/www.selectman.co.uk

Dig

ital

 Vid

eo

Digital Video

Revision 1.8 Date: 05/01/2009

Summary of Contents for SelectLine Video 16 Digital

Page 1: ...ectLine Selectine Select Manufacturing Limited Unit H1 The Seedbed Centre Wyncolls Road Severalls Business Park Colchester Essex CO4 9HT Telephone 44 0 1206 855800 Facsimile 44 0 1206 855801 E mail sa...

Page 2: ...Digital Video Installation Manual Engineers Notes...

Page 3: ...Digital Systems Digital Video Installation Manual...

Page 4: ...Current 4 5 6 DIGITAL SYSTEMS WIRING DETAIL Privacy Privacy Indicator and Door Monitoring Amplifier Wiring Detail Dual Landing Panel Display Wiring Detail Camera and Video Distributor Wiring Detail T...

Page 5: ...Telephone Handset to Strobe Sounder Controller to Door Release Monitor Contacts Systems to Door Release ac and dc Controller to Emergency Override Switch Controller to Request To Exit Button System W...

Page 6: ...or 0V 0V 0V MFL VC2 Mains Fail MFL 12V 12V 12V B B TC TC ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 1 CC DML SBL LS FCL LS1 LS2 SA SE LC LS 2 RTE T RTE T RTE...

Page 7: ...INE 5 LINE 6 LINE 7 LINE 8 LINE 9 LINE 10 LINE 11 LINE 12 LINE 13 LINE 14 LINE 15 LINE 16 1 C 2 6 9 PS PL DL LINE 3 5 Amp Fuses System Supply Indicator 0V 0V 0V MFL VC2 Mains Fail MFL 12V 12V 12V B B...

Page 8: ...Digital 50VAC Main Power Supply Overview Digital Video Installation Manual 6 230VAC to 50VAC Supply Fused Spur 50VAC Rail to a Controller AC2 5Amp Fuse AC1 Digital Video Revision 1 08 Date 05 01 2009...

Page 9: ...16 1 2 PAC1 PAC1 PAC Entrance 1 Input PAC Entrance 1 Input 0 PANEL 2 1 CC DML SBL LS FCL LS1 LS2 SA SE LC LS 2 PAC2 PAC2 0 PAC Jumpers See page 11 PAC Jumpers See page 11 Telephone Door open Tone ON...

Page 10: ...upply Indicator 18VDC Distributor Supply 12VDC Camera Supply 18 24VDC Monitor Supply 8 12V 12V 0V 0V 9 16 Output To Video Distributors Video Output To Next Controller Digital Panel 2 Input Digital Pan...

Page 11: ...1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9...

Page 12: ...9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL CC DML SBL RTE RTE FS FS SA SE LC LA...

Page 13: ...1 SA for Normally Closed and LS1 SE for Normally Open This will give Volt free contacts when a Lock release is initiated from the Telephone Monitor or system RTE is pressed For Fail Secure SE Lock Rel...

Page 14: ...ce Panel 1 Camera TC TC SIG SCN Emergency Override Switch For Fail Safe SA Lock Releases Common 1 Normally Open 4 Normally Closed 2 R T E N C N O SA LC Main or Landing Video Controller Landing Entranc...

Page 15: ...ion 1 09 Date 15 12 2010 Digital Panel 1 Input To PAC Controller CamDP1 Functional Video Panel with DDA display wiring detail Video Entrance Panel PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 Brown...

Page 16: ...ard A G R T RS232 D C B RS475 RS232 Transmission Input Output RS485 Transmission Input Output Concierge Building Interface Card Multi Building wiring detail PC Input Output Controller 2 Interface Card...

Page 17: ...5 6 7 8 2 DATA SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH 1 2 3 4 5 FUNCTION SWITCH 1 1 3 3 4 4 5 5 6 6 7 7 8 8 2 2 DATA SWITCH DATA SWITCH Controller Controller Controlle...

Page 18: ...5 digit engineering code has already been entered the Digital Panel will display EA1 alternating with the remaining 4 numbers i e EA1 2345 This can if required be deleted by pressing the CANCEL butto...

Page 19: ...To initiate the default setting the batteries must be disconnected and the Fused spur must be switched off This must be for a period of no less than 5 seconds or the extinguishing of the on board hea...

Page 20: ...e programming mode Note 1 When there is a need to edit or check an already programmed flat on the system use the following procedure Enter Controller number i e 2 Enter Line Output number i e 03 and p...

Page 21: ...ta Output Data Output 0volts Positive External Alarm Strobe Sounder Negative External Alarm Strobe Sounder Fail Safe Lock Release Output Fail Secure Lock Release Output Lock Release Common 12 24VAC DC...

Page 22: ...ite White of Blue White of Brown Brown of White Orange of White 2 5mm Mains Type Cable 2 5 Mains Type Cable Brown of White White of Brown Blue of White White of Blue Orange of White Green of White Dig...

Page 23: ...d Door Monitoring Indicator wiring detail 1 6 CA 9 10 2 PS PL DL Blue of White White of Blue White of Orange and Orange of White White of Green Green of White Brown of White White of Brown System Cont...

Page 24: ...t Programming Button _ 1 2 12V 0V SCN SIG CAM2 Lobby 12V 0V SCN SIG CAM1 Panel TC TC SIG Entrance Panel Camera 1 SCN Main and Riser Controller Video Board 12 18VDC Distributor Supply Vout Scn CamR Cam...

Page 25: ...ay Video Distribution Box Distributor Remove all jumpers except the LAST Distributor in the Video Distribution Box 19A Digital Entrance Panel Video Output to Cam DP on next Riser Controller U1 U2 E U5...

Page 26: ...ntinuity Video Coax To Riser Controller VOUT Distribution Supply To Riser Controller 4 8 12 and 16 Video Distribution wiring detail U1 U2 E U5 U3 U4 Video Distributor R2 R1 U1 U2 E U5 U3 U4 Video Dist...

Page 27: ...Video Monitor connection plate RD R3 R2 1 2 6 CA R1 R1 V4 V5 V3 10 9 X1 X2 Y1 Y2 Video Monitor wiring detail Distributor Remove all Jumpers on the Distributors except the LAST in line Normally remove...

Page 28: ...Timed Intercall Digital RTE Request To Exit Button 12VDC Auxiliary Output wiring detail PANEL 1 OV OV OV 12V 12V 12V 12VDC Auxiliary Output 12VDC Auxiliary Output 3Amp Overall Output 12VDC Auxiliary O...

Page 29: ...release power This is to protect the System Controller against back EMF If the locks are being powered by a PAC Controller then use the MOV supplied with the PAC reader DC Fail Safe Lock Release wirin...

Page 30: ...B DCIN L L Lock1 Relay 1 Reader1 V LED RTE DC SIG GND N C COM N O L L PAC EASIKEY 1000 System Controller The RED LED s must always be illuminated on both jumpers except on lock release PANEL 1 PAC PAC...

Page 31: ...GND Relay 2 N C COM N O B B DCIN L L Lock1 Relay 1 Reader1 V LED RTE DC SIG GND N C COM N O L L PAC EASIKEY 1000 PAC DDA READER DO CLK 0V VCA D1 SIG 10 5 28V 1 2 VE VE 12V 12V 0V Sw1 Prog Sw2 Up Load...

Page 32: ...Cam1P Scn Cam1L Scn Cam2L Scn Camera Supply x 2 Monitor Output Trades Clock Secondary Trades Clock Secondary Trades Clock Auxiliary Supplies 3 x 0V Output 3 x 12VDC Output Power Input to Controller 12...

Page 33: ...ly 18VDC Monitor Supply Entrance Panel Amplifier Detail Speaker Microphone 6VDC 6VDC Entrance Panel Detail Door Monitor Release Indicator Button Common Trades Detail Trades Button Trades Button Reques...

Page 34: ...Distributor Supply 0V Distributor Supply Video Inputs and Outputs SML2021 4 Video Signal Output to Distributor Video Screen Output to Distributor Video Riser Signal Output Video Riser Screen Output Vi...

Page 35: ...Serial link set up Medium Volume Electronic Call Privacy Time Call with Strobe Landing Entrance Door 1 Adjustable Time Functions Lock Release time Telephone Ringing time System active duration time D...

Page 36: ...nd the DATA switches to select the number of seconds for the ringing time duration Select the ring time duration using the TIME SELECTION seconds chart See Controller Programming Instruction Repeat fo...

Page 37: ...P P 0 0 1 E P P P P 0 1 0 E P P P P 0 0 0 E P P P P 1 0 0 E 1 0 0 0 0 0 1 0 0 1 0 0 0 0 1 0 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S 1 0 0 0 0 1...

Page 38: ...ion Time Entrance Panel 2 15 M inutes 4 0 1 0 0 0 0 1 1 1 1 1 1 1 1 0 0 Note 1 ON X Any Position 1 If an Extension Sounder or Strobe are required set Data switch 8 to ON 0 OFF S Seconds 2 Do not set a...

Page 39: ...The output status will change and indicate override is in operation by flashing Programming Only two setting buttons are required and Change Program In normal usethe Change Buttonis used to switch ON...

Page 40: ...anges to show the relay state and the day of the week for a few moments The right hand 8 digits shows the time in HH MM 24 hour format The colon flashes to show the clock is running The last digit sho...

Page 41: ...34 Digital Video Revision 1 08 Date 05 01 2009 Digital Video Installation Manual Engineers Notes...

Page 42: ...6 CC TR TR Note The CC connection on the Controller to the Entrance Panel button common should always be a pair I e Slate of Red and Red of Slate Controller to Entrance Panel Amplifier Controller 1 2...

Page 43: ...is the first colour stated above The banding is the second colour stated above Therefore a wire stated as Black of Slate would be a Black main colour with a Slate banding Lock Release Fail Safe DC Loc...

Page 44: ...switches located on the Controller motherboard below the Digital Trade clock Each of the above switches contains 8 ON and 8 OFF positions that can be selected in various combinations to achieve varyin...

Page 45: ...tivate the system timer and illuminate the Privacy On indicator stopping all incoming calls for a timed period You can at any time if you wish cancel the timed Privacy period by pressing the Privacy O...

Page 46: ...nt Name Commissioning Engineer Installer Name Site Address Telephone No Controller No Comments SELECT General System Comments Please use reverse Trades On On On On Off Off Off Off Trades settings Flat...

Reviews: