Selecon Pacific Dowser Operation Manual Download Page 10

Pacific Dowser Manual

10

10

Version 5: January 2005            

©

 2004 Selecon New Zealand Limited All Rights Reserved

Fault Guide

Problem

Check

Unit plugged in

Does not respond 
(LED Display is not on)

Fuse status 
Damage to DMX cable

Does not respond to DMX control
(Green LED is not on, LED Display is
on)

Damage to DMX cable
Local level is set to {00}

DMX address 

Does not respond to DMX control
(Green LED is on, LED Display is on)

DMX Termination Switch
Damage to DMX cable

Unit flickers/reacts in random way

Only the last unit in DMX line terminated/termination
switch on

Dimensions

500 mm

1093 mm

270 mm

PAC 5.5

0

-13

0

 Zoom

Summary of Contents for Pacific Dowser

Page 1: ...A SELECON PACIFIC LUMINAIRE ACCESSORY WE HAVE DESIGNED THIS LUMINAIRE ACCESSORY TO PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE DESIGN ENGINEERING WE ARE CONFIDENT THAT IT WILL PERFORM TO YOUR...

Page 2: ...s no liability for direct indirect incidental special or consequential damages resulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manu...

Page 3: ...rmance Warning 5 Assembling the Dowser onto a Pacific 6 Powercon Connector 7 Dowser Control Panel 7 DMX Operation 7 DMX Address Setting 7 Local Level Control 7 Display Setting 8 Recommended DMX Distri...

Page 4: ...le for mounting on a normally flammable surface These luminaires are not suitable for outdoor use They are rated at IP00 The Pacific range can be operated only through a range of angles 90 either side...

Page 5: ...nd a secure independent anchor point Prolonged use of the dowser with the arms closed and the light source on will result in damage to the dowser and is not covered under warranty Performance Warning...

Page 6: ...ke as shown above or for situations where the unit is to be underslung rotate the yoke 1800 Slide the lamp house sideways into place into the lamp house slot and turn the lamphouse clockwise so the la...

Page 7: ...types of operation The dowser has the following user adjustable features 1 DMX Address for remote operation 2 Local control for stand alone operation 3 Display on low off DMX Operation The dowser acce...

Page 8: ...s on then the dowser is receiving a DMX signal and is under DMX control local level is set to 00 If the DMX Status LED is off then the dowser is not receiving a DMX signal OR is under local control Te...

Page 9: ...duration of the performance 2 If the dowser and MSR ballast are on separate non dim circuits The dowser can be switched independently to the ballast If desired the lamp can be switched on when require...

Page 10: ...ge to DMX cable Does not respond to DMX control Green LED is not on LED Display is on Damage to DMX cable Local level is set to 00 DMX address Does not respond to DMX control Green LED is on LED Displ...

Page 11: ...ST Hot Restrike 150W CDM 70W CDM Safe Practice Mains Isolation The unit and luminaire should always be electrically isolated from mains power before re lamping cleaning or servicing Safety Selecon ha...

Page 12: ...y is to repair replace or service a luminaire subject to a valid warranty claim Under no circumstance will Selecon be liable for direct indirect incidental special or consequential costs or damages in...