8.00 Spare parts list 

Part

 

Part no.

 

Premix tap chrome

 

23-0628-0000 

Premix tap gilded

 

23-0628-0008 

Drip tray VA 245/170/11

 

41-0124-0000 

Thermostat

 

50-0133-0000 

Thermostat button

 

50-0103-0000 

 

 

Please use only original spare parts

 

 

 
 
 

9.00 Data on noise emission 

70 dB (A) specification from EN 292 Part 2 A1 
With gauges that are 70 dB (A) or lower, specification "70 dB (A)" is sufficient 

 
 
 

9.10 Technical data 

Voltage  

 

240 V 50Hz

 

Electricity   1.6 

A

 

Output  

 

190 W

 

Coolant  

 

190 g R 134a

 

Tap standby 

 

5 min.

 

Tap output 

 

40 l/h at delta t 10K

 

Coolant output   

465 W

 

H / W / D in mm  

408/308/410

 

Weight:  

 

24  kg

 

 

Summary of Contents for WT 40

Page 1: ...21 95 68 01 0 Fax 49 0 21 95 68 01 188 Email info selbach com Internet http www selbach com Instructions for use WT 40 Wine Cooler The appliance described here may only be used by properly trained ope...

Page 2: ...ECTRICAL CONNECTION 4 1 51 Wine connection 4 1 52 Operation 4 1 60 SERVICE 4 2 00 USE IN ACCORDANCE WITH REGULATIONS 4 3 00 BRINGING INTO SERVICE 5 3 10 CONNECTION 5 4 00 PLACING OUT OF OPERATION 5 5...

Page 3: ...nnel Adjustment maintenance and repairs to the appliance when it is open or connected to the electricity supply may only be carried out by experts As with all technical appliances problem free functio...

Page 4: ...tion Wine is connected via the beverage supply lines on the bottom of the appliance It is essential that the appliance is placed upright immediately following connection of supply lines 1 52 Operation...

Page 5: ...no foreign particles can access gas and wine connections The pressurised gas bottles may only be operated with pressure regulators and must always be upright and prevented from falling over This ensu...

Page 6: ...ll and lead to cloudiness A germ infested wine connection can contaminate the adjoining vessel container whereas filling was originally closed off and free from biological problems The environment of...

Page 7: ...ot cool Thermostat faulty Condenser dirty Condenser ventilator not working Leakage in cooling system Compressor faulty Change thermostat Clean condenser Change ventilator Remove leak evacuate and fill...

Page 8: ...000 Please use only original spare parts 9 00 Data on noise emission 70 dB A specification from EN 292 Part 2 A1 With gauges that are 70 dB A or lower specification 70 dB A is sufficient 9 10 Technica...

Reviews: