EM00136061

rev. 2.5

EN

8

Paragraph 8 – Timed Dosage

(Frequency signal input “TRIGGER” not activated)

Programming

Operation

+

-

-
-
-

+

-

+

-

+

-

Tempo

Quantity

100ml

Delay

0.01.50

Interval

0.01.50

PROG

Time

Time

g.hh.mm

Time

g.hh.mm

Configuration

Pum functions

Configuration

Pum functions

-
-

Trigger Mode

Pause Input Mode

Disable

Restart Timer

+

-

-

Pause Input Mode

Restart Timer

-

Pause Input Mode

Freeze Time

Pause Input Mode

Pause Dosing

The pump doses a programmed quantity in ml. It is possible to set a

pump delay time (

Delay

) when the pump is started and an interval

between two successive dosings (

Interval

), as illustrated in the

diagram:

The

Delay

and

Interval

times are in dd.hh.mm (days, hours,

minutes)

The

Pause

input can be programmed in three different modes:

1.

FreezeTime:

when the pause is activated, the system cuts

out the current time count and restarts it when the pause is

deactivated.

2.

Pause Dosing:

with the pause activated, the system

continues to count time the and stops the dosing.

3.

Restart Timer

: when the pause is activated, the system

stops the dosing and when the pause is deactivated the

count starts again from the beginning.

The dosage frequency can be modified while the pump is operating,
by pressing the

keys at the same time to increase the

frequency, or the

keys to decrease it.

Display during Operation

Display at start-up (MODE key)

Timer

F

F

F

7.0 ml

Liv

Stop

P 0%

Operating mode



Timer



Alarms and Level
statuses = level alarm



Flow = flow alarm

FLOW

sensor

status

Programmed value



Quantity in ml

Pump status



Dry = pump starting up



Stop = pump stopping



Restart = pump restarting

Value of dosing in
progress:



Percentage of
strokes/min max

Q.tà

20,0ml

20,0ml

P 100%

Operating mode



The following are shown in sequence:
quantity to dose, delay in d.hh.mm.
and interval in d.hh.mm

Dosing value



Programmed
quantity in m

l

Value of the dosing percentage,
which can be modified by
pressing the + or – keys

Paragraph 9 – Setting the Maximum Flow

Programming

Operation

-
-

-

Pump Functions

Max flow rate

Max flow rate

Max flow rate

P100%

P100%

F320s/m

PROG

-

+

-

+

-

This makes it possible to set the maximum flow offered by

the pump, and the programmed mode (% or frequency) is

used as the standard unit of measurement when displaying
the flow. Changes can be made by pressing the

key,

then using the

keys to set the new value. Press

to confirm and return to the main menu

Delay

Interv.

Quantity

www.winwinpoolshop.com

Summary of Contents for TEKNA EVO TPG

Page 1: ...S FR IT PT TR RU TEKNAEVO TPG INSTALLATION MANUAL HANDBUCH MANUAL DE INSTALACION MANUEL D INSTALLATION MANUALE D INSTALLAZIONE MANUAL DE INSTALAÇÃO KULLANIM KLAVUZU РУКОВОДСТВО ПО УСТАНОВКЕ И ЭКСПЛУАТАЦИИ www winwinpoolshop com ...

Page 2: ...signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decrease the numerical values to be changed Flashing green LED during dos...

Page 3: ... be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit to confirm the selection Don t Save Save Pump Funtions Configuration Pump Functions Pump Functions Paragrafo 1 Paragraph 10 Paragraph 11 Paragraph 12 Paragrafo 13 Paragraph 14 Paragraph 15 Paragraph 16 Paragraph 9 Paragraph 2 Paragraph 3 Paragraph 4 Paragraph 5 Paragraph 6 ...

Page 4: ...arms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosage speed depends on selected unit of measurement Percentage Frequency l h Gph ml m MAN P100 Operating mode Man during manual modification of the flow it displays the corresponding frequency value Current dosage value Modify the maximum flow by pressing the or keys at the same time Paragraph ...

Page 5: ...ev Level alarm Flw Flow alarm FLOW sensor status Programmed value Programmed interval value default 20 4 Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosage value depends on the selected unit of measurement Percentage Frequency l h Gph ml m High 0 0 0 mA P100 Operating mode Displays the Low and High value in sequence Input mA value Current dosage value Makes it p...

Page 6: ...ng Operation Display during Setting MODE key N 1 F F F 4 Lev Stop P100 Operating mode 1 n impulse multiplication Alarms and statuses Lev Level alarm Flw Flow alarm FLOW sensor status Programmed value of n Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosage value Maximum dosage percentage n 1 6 6 P100 Operating mode Programmed value Value of n Current dosage value...

Page 7: ...ternal signal i e impulse launch counter automatically calculating the relationship between incoming signals and pump strokes on the basis of the programmed ppm value The data to be entered is the ppm value the impulse litre ratio or litre impulse of the counter and the concentration of the product to be dosed The dosage frequency can be modified during operation by pressing the keys at the same t...

Page 8: ...Closed it is activated when the input passes from the closed to the open mode The Trigger signal is locked during dosing its receipt is neither stored nor managed The Pause Remote input input cannot be programmed and its activation stops the dosing while its further deactivation makes the system wait again for the Trigger signal for a new dosing The dosage frequency can be modified while the pump ...

Page 9: ...unt starts again from the beginning The dosage frequency can be modified while the pump is operating by pressing the keys at the same time to increase the frequency or the keys to decrease it Display during Operation Display at start up MODE key Timer F F F 7 0 ml Liv Stop P 0 Operating mode Timer Alarms and Level statuses level alarm Flow flowalarm FLOW sensor status Programmed value Quantity in ...

Page 10: ...librated in two different ways MANUAL manually enter the cc value per strike using the keys and confirm by pressing the key AUTOMATIC the pump makes 100 strikes which are started by pressing the key At the end of this process enter the quantity sucked up by the pump using the keys and confirm by pressing the key The entered figure will be used in flow calculations Paragraph 12 Statistics Programmi...

Page 11: ...umber flashes when you press the key and you can then use the keys to set the value Confirm by pressing the key Press to return to the main menu Paragraph 15 Level Alarm Programming Operation Alarm Level Alarm Flow Alarms Level Stop Alarms Level Alarm Stop Alarm PROG ESC This makes it possible to set the pump when the level sensor alarm is activated In other words you can decide whether to stop do...

Page 12: ... Restore the liquid level I e Man Lev P100 Fixed alarm LED Flashing words Lev and stop End of level alarm with interruption to pump operation Restore the liquid level I e Man Lev Stop P100 Flashing word Mem The pump receives one or more pulses during dosage with memory function on Off Press the key I e 1 n 6 Mem Flashing word Mem The pump receives one or more pulses during dosage with memory funct...

Reviews: