TEKNAEVO TPG

INSTALLATION MANUAL

HANDBUCH

MANUAL DE INSTALACION

MANUEL D’INSTALLATION

MANUALE D’INSTALLAZIONE

MANUAL DE INSTALAÇÃO

KULLANIM KLAVUZU

РУКОВОДСТВО ПО УСТАНОВКЕ И ЭКСПЛУАТАЦИИ

www.winwinpoolshop.com

Summary of Contents for TEKNA EVO TPG

Page 1: ...S FR IT PT TR RU TEKNAEVO TPG INSTALLATION MANUAL HANDBUCH MANUAL DE INSTALACION MANUEL D INSTALLATION MANUALE D INSTALLAZIONE MANUAL DE INSTALAÇÃO KULLANIM KLAVUZU РУКОВОДСТВО ПО УСТАНОВКЕ И ЭКСПЛУАТАЦИИ www winwinpoolshop com ...

Page 2: ...signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decrease the numerical values to be changed Flashing green LED during dos...

Page 3: ... be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit to confirm the selection Don t Save Save Pump Funtions Configuration Pump Functions Pump Functions Paragrafo 1 Paragraph 10 Paragraph 11 Paragraph 12 Paragrafo 13 Paragraph 14 Paragraph 15 Paragraph 16 Paragraph 9 Paragraph 2 Paragraph 3 Paragraph 4 Paragraph 5 Paragraph 6 ...

Page 4: ...arms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosage speed depends on selected unit of measurement Percentage Frequency l h Gph ml m MAN P100 Operating mode Man during manual modification of the flow it displays the corresponding frequency value Current dosage value Modify the maximum flow by pressing the or keys at the same time Paragraph ...

Page 5: ...ev Level alarm Flw Flow alarm FLOW sensor status Programmed value Programmed interval value default 20 4 Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosage value depends on the selected unit of measurement Percentage Frequency l h Gph ml m High 0 0 0 mA P100 Operating mode Displays the Low and High value in sequence Input mA value Current dosage value Makes it p...

Page 6: ...ng Operation Display during Setting MODE key N 1 F F F 4 Lev Stop P100 Operating mode 1 n impulse multiplication Alarms and statuses Lev Level alarm Flw Flow alarm FLOW sensor status Programmed value of n Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosage value Maximum dosage percentage n 1 6 6 P100 Operating mode Programmed value Value of n Current dosage value...

Page 7: ...ternal signal i e impulse launch counter automatically calculating the relationship between incoming signals and pump strokes on the basis of the programmed ppm value The data to be entered is the ppm value the impulse litre ratio or litre impulse of the counter and the concentration of the product to be dosed The dosage frequency can be modified during operation by pressing the keys at the same t...

Page 8: ...Closed it is activated when the input passes from the closed to the open mode The Trigger signal is locked during dosing its receipt is neither stored nor managed The Pause Remote input input cannot be programmed and its activation stops the dosing while its further deactivation makes the system wait again for the Trigger signal for a new dosing The dosage frequency can be modified while the pump ...

Page 9: ...unt starts again from the beginning The dosage frequency can be modified while the pump is operating by pressing the keys at the same time to increase the frequency or the keys to decrease it Display during Operation Display at start up MODE key Timer F F F 7 0 ml Liv Stop P 0 Operating mode Timer Alarms and Level statuses level alarm Flow flowalarm FLOW sensor status Programmed value Quantity in ...

Page 10: ...librated in two different ways MANUAL manually enter the cc value per strike using the keys and confirm by pressing the key AUTOMATIC the pump makes 100 strikes which are started by pressing the key At the end of this process enter the quantity sucked up by the pump using the keys and confirm by pressing the key The entered figure will be used in flow calculations Paragraph 12 Statistics Programmi...

Page 11: ...umber flashes when you press the key and you can then use the keys to set the value Confirm by pressing the key Press to return to the main menu Paragraph 15 Level Alarm Programming Operation Alarm Level Alarm Flow Alarms Level Stop Alarms Level Alarm Stop Alarm PROG ESC This makes it possible to set the pump when the level sensor alarm is activated In other words you can decide whether to stop do...

Page 12: ... Restore the liquid level I e Man Lev P100 Fixed alarm LED Flashing words Lev and stop End of level alarm with interruption to pump operation Restore the liquid level I e Man Lev Stop P100 Flashing word Mem The pump receives one or more pulses during dosage with memory function on Off Press the key I e 1 n 6 Mem Flashing word Mem The pump receives one or more pulses during dosage with memory funct...