3.1.2 Factory
settings
A new pump from the factory is set as follows:
Operating Mode
Constant
Flow Rate Display
Percentage (100%)
Working Frequency
Maximum (240)
Stroke Maximum
Operation STOP
Icons “lit”
STOP
C
and
%
3.1.3 Priming
The priming function is useful for speeding up installation of the pump as it makes the pump work at maximum
frequency, independently of the parameter settings.
Priming can be activated both when the pump is running and when the pump is stopped (
STOP
icon lit).
Activate the pump by pushing the
START/STOP
button (
STOP
icon off). Press the
▲
and
▼
keys together.
The pump starts at maximum frequency. The display reads: P100, F240 o XX.X (value taken from calibration).
When the
▲
and
▼
keys are released the pump goes back to its previous state.
3.1.4
Adjusting the flow rate
The flow rate can be adjusted in two ways:
−
By adjusting the operating frequency setting.
−
By adjusting the stroke using the relevant knob of the front.
Fine tuning of dosing can be obtained by combining these two settings. By adjusting the stroke you
can set the pump to maximum flow rate, which can be refined by adjusting the operating frequency.