9
TECHNICAL GUIDE
Cal. V182A
III. VALUE CHECKING
•
Coil block resistance
1.8K
Ω
~ 2.2K
Ω
•
Current consumption
For the whole movement
:
Less than 0.8
µ
A (with voltage supplied from a battery)
For the circuit block alone
:
Less than 0.4
µ
A (with voltage supplied from a battery)
<Measuring the current consumption for the whole movement>
1) Remove the solar cell unit and rechargeable battery.
2) Connect the tester as shown in the illustration.
3) Start the measurement 30 seconds to 2 minutes after connecting the tester, checking that a stable
measurement is obtained.
S-850
Input pattern (–)
Battery connection (+)
MA-40A