background image

TECHNICAL GUIDE

Cal. V116A

16/16

l

  

Checking the water resistance

Check the water resistance according to the designated specification of the watch.

Marking on the case back

Test method

Applied pressure

   WATER RESISTANT (WATER RESIST) 

3 BAR

WATER RESIST 5BAR

5 BAR

WATER RESIST 10BAR

10 BAR

WATER RESIST 15BAR

15 BAR

WATER RESIST 20BAR

20 BAR

SCUBA DIVER'S (AIR DIVER'S) 150 m

18.75 BAR = 150 (m) times 0.125

SCUBA DIVER'S (AIR DIVER'S) 200 m

 

25 BAR = 200 (m) times 0.125

He-GAS DIVER'S 300 m

37.5 BAR = 300 (m) times 0.125

He-GAS DIVER'S 600 m

75 BAR = 600 (m) times 0.125

He-GAS DIVER'S 1000 m

125 BAR 

 = 1000 (m) times 0.125

Water pressure test

Condensation test

Condensation test

Condensation test

Water pressure test

Air leak test

l

  

Accuracy test

  

Measure the rate and make sure the value shows within 

±0.50 s/d.

Use 10 seconds gate of the tester.

Copyright©2011 by 

TG V116A.indd   16

11/08/01   9:55

Summary of Contents for V116A

Page 1: ...ond intervals 4002 909 1 20 1 60 K Circuit block Less than 0 16 A Movement Less than 0 22 A Time setting hand position adjustment resetting the circuit Free Outside 11 6 mm x 15 55 mm Casing 11 6 mm x...

Page 2: ...le battery decreases it is necessary to have the watch repaired Environment Light source Illumination lux Time required for full charge Time required for steady operation Time to charge 1 day of power...

Page 3: ...ands 3 Case ring 2 PCS Movement 4020 582 Solar cell unit 7 0271 946 Hour wheel 6 0491 735 Dial washer 5 4246 644 Solar cell lead terminal 2pcs 4 Please see the remarks on the following pages Disassemb...

Page 4: ...k cover screw 9 4461 526 Circuit block cover 24 0282 804 Clutch wheel 25 4239 909 Rotor stator 26 0100 578 Main plate 21 0389 909 Setting lever spring 22 0383 806 Setting lever 23 0351 861 Setting ste...

Page 5: ...UE in order to choose corresponding parts 3 CASE RING 8277 2020 The type of case ring is determined based on the design of cases Check the case number and refer to the Parts Catalogue web site to choo...

Page 6: ...l securely as it easily comes out of position 3 CASE RING Note The complete case ring is constructed with 2 same half case rings One is used for the 12 o clock side and the other one is used for the 6...

Page 7: ...removing or installing the solar cell unit take care not to damage the solar cell If the solar cell is damaged its power generating capacity may be greatly decreased In that case check the output volt...

Page 8: ...chargeable battery unit will be deteriorated Never wash the rechargeable battery unit as it is an electronic part 9 CIRCUIT BLOCK COVER How to remove Remove the two circuit block cover screws and then...

Page 9: ...ition and lubricating Refer to the illustrations below for the setting position and lubrication of the respective wheels Lubriccating Types of lubricant Watch oil AO 3 Watchi oil AO 2 Lubricang quanti...

Page 10: ...ustration below for the setting position and lubrication of the respective parts Have the spring portion of the yoke securely catchtheprotrudedportionofthemainplate A portion in the illustration Note...

Page 11: ...cuit the minus probe and circuit block cover 4 After checking that a stable measurement is obtained with the tester connected read the current consumption As the hands move at 20 second intervals 3 to...

Page 12: ...urement value may be obtained 3 After checking that a stable measurement is obtained with the tester connected read the current consumption Structure of the circuit block Coil output terminal Crystal...

Page 13: ...asshownintheillustration atrighttomeasurethevoltageoftherechargeablebattery before recharge initial voltage 2 Place the watch at a distance of 5 cm under a fluorescent light of 15 to 20 watts and char...

Page 14: ...the table below to determine whether the recharging function is normal or not Initial voltage and guidelines of normal defective decision Initial voltage Guidelines of normal defective decision 0 5 V...

Page 15: ...times Setting mechanism function of the time setting Make sure that it has a click at the 1st click position and the stem is not pulled off Pull out the crown to the 1st click then turn it Setting mec...

Page 16: ...ESIST 20BAR 20 BAR SCUBA DIVER S AIR DIVER S 150 m 18 75 BAR 150 m times 0 125 SCUBA DIVER S AIR DIVER S 200 m 25 BAR 200 m times 0 125 He GAS DIVER S 300 m 37 5 BAR 300 m times 0 125 He GAS DIVER S 6...

Reviews: