Seiko 6R15 Instructions Manual Download Page 20

77

Notes on skin  

irritation and allergy

Skin irritation caused by a band has various reasons such as  

allergy to metals or leathers, or skin reactions against friction on 

dust or the band itself. 

Notes on the 

length of the band

Adjust the band to allow a little clearance with your wrist to 

ensure proper airflow. When wearing the watch, leave enough 

room to insert a finger between the band and your wrist.

・Polyurethane band

・ Do not expose the watch to direct sunlight for a long time.
・ Please take care when wearing a watch with light-colored band, as dirt is likely to show up.
・ Refrain from wearing a leather band watch other than Aqua Free bands while bathing, swimming, and when  

  working with water even if the watch itself is water-resistant enforced for daily use (10-BAR water resistant).

・ A polyurethane band is susceptible to discoloration from light, and may be deteriorated by solvent or  

   atmospheric humidity.

・ Especially a translucent, white, or pale colored band easily adsorbs other colors, resulting in color smears or  

   discoloration.

・ Wash out dirt in water and clean it off with a dry cloth.

  (Protect the watch body from water splashes by wrapping it up in plastic wrap etc.)

・ When the band becomes less flexible or cracked, replace the band with a new one.

Band

 (maintenance procedure)

・Metallic band

・Leather band

・ Moisture, sweat or soil will cause rust even on a stainless steel band if they are left for a long time.
・ Lack of care may cause a yellowish or gold stain on the lower sleeve edge of shirts.
・ Wipe off moisture, sweat or soil with a soft cloth as soon as possible
・ To clean the soil around the joint gaps of the band, wipe it out in water and then brush it off with a   

   soft toothbrush.
  (Protect the watch body from water splashes by wrapping it up in plastic wrap etc.)

・ Because some titan bracelets use pins made of stainless steel, which has outstanding strength, 

  rust may form in the stainless steel parts.

・ If rust advances, pins may poke out or drop out, and the watch case may fall off the bracelet, or the 

  clasp may not open.

・ If a pin is poking out, personal injury may result.  In such a case,  refrain from using the watch and request repair.

・ A leather band is susceptible to discoloration and deterioration from moisture, sweat and direct sunlight.
・ Wipe off moisture and sweat as soon as possible by gently blotting them up with a dry cloth.

The band touches the skin directly and becomes dirty with sweat or dust. Therefore, 
lack of care may accelerate deterioration of the band or cause skin irritation or stain 
on the sleeve edge. The watch requires a lot of attention for long usage.

76

75

Examples of common magnetic products that may aff ect watches

Cellular phone 

(speaker)

Bag

 (with magnet buckle)

AC-powered

shaver

Portable radio 

(speaker)

Magnetic

cooking device

Magnetic

health pillow

Magnetic 

necklace

AC adapter

Magnetic resistance

(affect of magnetic field)

74

Aff ected by nearby magnetism, 

a  watch may temporarily gain or lose time or stop operating.

If the watch becomes magnetized and its accuracy deteriorates to an extent exceeding the specifi ed 
rate under normal use, the watch needs to be demagnetized. In this case, you will be charged for 
demagnetization and accuracy readjustment even if it happens within the guarantee period.
The reason why watch is aff ected by magnetism
The built-in balance spring may be infl uenced by a strong external magnetic fi eld.

Indication on the case back

Condition of use

No indication

Keep the watch more than 5 cm away from 
magnetic products. (JIS level-1 standard)

Keep the watch more than 1 cm away from 
magnetic products. (JIS level-2 standard)

Summary of Contents for 6R15

Page 1: ...6R15 BSB6R15 A1909 I N S T R U C T I O N S Mechanical Watch M...

Page 2: ...20 5 8 10 20 22 24 26 30 32 34 40 41 42 44 4 5 35 3 2...

Page 3: ...9 8...

Page 4: ...1 1 6 5 6 13 13 9 1 24 1 0 12 12 1 10 11 1 2 3 0 12 6 4 50 10...

Page 5: ...9 1 17 2 1 28 29 1 30 1 1 31 1 1 1 16 15 0 2 1 2 12 0 TEL 117 14...

Page 6: ...21 7 20...

Page 7: ...WATER RESISTANT 10BAR 7N01 0B40 R2 AG W A TER RESISTANT 10B A R 7N01 0B40 AG R2 25 24 P 20 23 1 22...

Page 8: ...29 BAR 28 27 P 25 WATER RESISTANT WATER RESISTANT 5 BAR 5 WATER RESISTANT 10 20 BAR 10 20 26...

Page 9: ...10 33 32 AC 31 5 JIS1 1 JIS2 30...

Page 10: ...37 36 2 3 4 35 LUKIA 34...

Page 11: ...12 3 41 10 500 3 5 100 000 10 000 3 000 1 000 3 000 1 000 40W 1m 1 000 3m 500 4m 250 40 39 38...

Page 12: ...2 4 5 6 3 6R15 3 21 600 23 50 25 15 5 35 44 43 1 1 42...

Page 13: ...y observed 49 WARNING Keep the watch and accessories out of the reach of babies and children WARNING Immediately stop wearing the watch in following cases If the watch body or band becomes edged by co...

Page 14: ...gain by turning it clockwise while pressing it If the crown turns out to be too sti to be screwed up turn the crown counterclockwise once and then give another try Do not screw it in by force as it ma...

Page 15: ...k for example be sure to wind it up fully every day at a xed time If you use a watch that has stopped with the mainspring unwound winding the mainspring with the crown will not start the watch immedia...

Page 16: ...The mechanism of mechanical watches is di erent from that of quartz watches When setting the time be sure to turn back the minute hand a little behind the desired time and then advance it to the exac...

Page 17: ...his mechanism works properly all the time washing parts changing oil adjusting accuracy checking functions and replacing consumable parts on a regular basis are important The rst overhaul after the pu...

Page 18: ...o claim free repair services The case dial hands glass and bracelet or parts thereof may be repaired with substitutes if the originals are not available If necessary movements will be replaced For len...

Page 19: ...not been conducted on the water resistant watch with the BAR barometric pressure display For diving use special watches for diving If the inner surface of the glass is clouded with condensation or wa...

Page 20: ...tect the watch body from water splashes by wrapping it up in plastic wrap etc Because some titan bracelets use pins made of stainless steel which has outstanding strength rust may form in the stainles...

Page 21: ...the band into the moveable loop and xed loop and fasten the clasp by pressing the frame of the buckle How to wear or take o the watch No Fixed loop with Metal Bracelets Type 80 Type 1 Lift up the cla...

Page 22: ...umiBrite is a luminous paint that is completely harmless to human beings and natural en vironment containing no noxious materials such as radioactive substance LumiBrite is a newly developed luminous...

Page 23: ...requently for the self winding type and winding up the mainspring fully everyday at a xed time to move it regularly for the wind up mechanical type E ect of magnetism When a ected by a strong magnetis...