background image

12

[en]

Quick Installation Guide

Configuring the ThinPrint® Gateway

The TPG-125 has a user interface, the TPG Control Center, which can be opened
in an Internet browser (Internet Explorer, Mozilla Firefox, Safari).

The TPG-125 can be configured and monitored via the TPG Control Center.

Proceed as follows:

1.

Open your browser.

2.

Enter the IP address of the TPG-125 as the URL.

The TPG Control Center appears in the browser.

If the TPG Control Center is not displayed, check the proxy settings of your browser.

Detailed information about the configuration of the TPG-125 
can be found in the Online Help of the TPG Control Center. 
To start the Online Help, click the '?' icon.

Summary of Contents for ThinPrint TPG-125

Page 1: ...oftware Installation Getting Started Configuring the ThinPrint Gateway Please note the table of contents on page 3 Should you have any further questions please contact our support hotline Überblick de Dieser Quick Installation Guide beinhaltet eine Beschreibung der Installation des TPG 125 Sie erhalten die folgenden Informationen Allgemeine Information Sicherheitsvorschriften Hardware Installation...

Page 2: ...2 Quick Installation Guide Date of Manufacture The serial number includes the date of manufacture The serial number can be found on the type plate ...

Page 3: ... Data 5 LED Display 6 2 Safety Regulations 8 2 Hardware Installation 9 2 Finding the TPG 125 in the Network 10 Installing and Starting the InterCon NetTool 10 Finding the TPG 125 Determining the IP Address 11 Changing the IP Address 11 2 Configuring the ThinPrint Gateway 12 Table of Contents ...

Page 4: ...mbedded ThinPrint Client The TPG 125 allows you to embed up to twelve network printers into the network The administration of the TPG 125 is done via the TPG Control Center Scope of Supply Please check the package content before getting started TPG ThinPrint Gateway TPG 125 Quick Installation Guide The Quick Installation Guide provides a brief description of the installation of the TPG 125 This do...

Page 5: ...ironment Ambient temperature 5 40 C Relative humidity 20 80 Dimensions Width 140 mm Height 32 mm Depth 99 mm Weight 150 g 1 Network status LED green 2 Activity LED green 3 Server communication LED green orange red 4 Print status LED green orange red 5 Network connector RJ 45 for 1000BaseT 100BaseTX and 10BaseT 6 USB port for the saving of parameters buffering of print jobs etc 7 Status reset butto...

Page 6: ...igured There is currently no communication with the ThinPrint server The ThinPrint Connection Service has been configured and established There is currently no communication with the ThinPrint server A The Connection Service has not been configured Currently communication takes place with the ThinPrint server B The ThinPrint Connection Service has been configured and established Currently communic...

Page 7: ...ed The status and the messages of some printers could be queried Printers have been configured The status and the messages of some printers could be queried Print jobs will be buffered for printers of which the status and messages could not be queried Printers have been configured No printer statuses and messages could be queried Printers have been configured No printer statuses and messages could...

Page 8: ...ids The device must only be connected and operated if it is in perfect condition Make sure that no one steps on or stumbles over the cables If the supplied power cord cannot be used in your country acquire an appropriate power cord that suits national provisions For more information please consult your retailer Do not connect a telephone cable to the RJ 45 connector The RJ 45 connector may only be...

Page 9: ...n 9 Hardware Installation The TPG 125 supports communication between up to twelve network printers and ThinPrint servers Proceed as follows 1 Connect the network cable RJ 45 to the TPG 125 2 Connect the power cord to the TPG 125 ...

Page 10: ...n a suitable IP address to the TPG 125 as described below Installing and Starting the InterCon NetTool 10 Finding the TPG 125 Determining the IP Address 11 Changing the IP Address 11 The client printer and TPG 125 must be assigned to the same local network segment Installing and Starting the InterCon NetTool Proceed as follows 1 Download the installation file for the InterCon NetTool from the home...

Page 11: ...e TPG 125 has assigned itself an IP address via ZeroConf from the address range 169 254 0 0 16 which is reserved for ZeroConf it will be displayed in the device list under the ZeroConf filter Assign a new IP address to the TPG 125 see Changing the IP Address 11 Changing the IP Address Wizards facilitate the installation and configuration of network devices via the InterCon NetTool The IP Wizard is...

Page 12: ...onfigured and monitored via the TPG Control Center Proceed as follows 1 Open your browser 2 Enter the IP address of the TPG 125 as the URL The TPG Control Center appears in the browser If the TPG Control Center is not displayed check the proxy settings of your browser Detailed information about the configuration of the TPG 125 can be found in the Online Help of the TPG Control Center To start the ...

Page 13: ...Quick Installation Guide en 13 ...

Page 14: ...14 en Quick Installation Guide ...

Page 15: ...ang 16 Technische Daten 17 LED Anzeige 18 2 Sicherheitsvorschriften 20 2 Hardware Installation 21 2 TPG 125 im Netzwerk finden 22 InterCon NetTool installieren und starten 22 TPG 125 finden IP Adresse ermitteln 23 IP Adresse ändern 23 2 ThinPrint Gateway konfigurieren 24 Inhaltsverzeichnis ...

Page 16: ...erten ThinPrint Client Über das TPG 125 lassen sich bis zu zwölf Netzwerkdrucker in das Netz einbinden Die Verwaltung des TPG 125 erfolgt über das TPG Control Center Lieferumfang Bitte überprüfen Sie den Packungsinhalt auf Vollständigkeit bevor Sie die Installation beginnen TPG ThinPrint Gateway TPG 125 Quick Installation Guide Der Quick Installation Guide beinhaltet eine kurze Beschreibung der In...

Page 17: ... 40 C Relative Luftfeuchtigkeit 20 80 Abmessungen Breite 140 mm Höhe 32 mm Tiefe 99 mm Gewicht 150 g 1 Netzwerkstatus LED grün 2 Activity LED grün 3 Serverkommunikation LED grün orange rot 4 Druckstatus LED grün orange rot 5 Netzwerkanschluss RJ 45 für 1000BaseT 100BaseTX und 10BaseT 6 USB Port u a für die Parametersicherung und das Zwischenspeichern von Druckaufträgen 7 Status Reset Taster 8 Ansc...

Page 18: ...ion Service ist nicht konfiguriert Momentan findet keine Kommunikation mit dem ThinPrint Server statt Der ThinPrint Connection Service ist konfiguriert und etabliert Momentan findet keine Kommunikation mit dem ThinPrint Server statt A Der ThinPrint Connection Service ist nicht konfiguriert Momentan wird mit dem ThinPrint Server kommuniziert B Der ThinPrint Connection Service ist konfiguriert und e...

Page 19: ...fragt werden Es sind Drucker konfiguriert Der Status und die Meldungen einiger Drucker konnten abgefragt werden Druckaufträge werden zwischengespeichert für Drucker deren Status und Meldungen nicht abgefragt werden konnten Es sind Drucker konfiguriert Es konnten keine Status und Meldungen von Druckern abgefragt werden Es sind Drucker konfiguriert Es konnten keine Status und Meldungen von Druckern ...

Page 20: ...sehrtem Zustand angeschlossen und betrieben werden Verlegen Sie alle Kabel so dass niemand darauf treten oder darüber stolpern kann Falls das beiliegende Netzkabel für Ihr Land nicht einsetzbar ist beschaffen Sie ein passendes Netzkabel mit der jeweiligen nationalen Zulassung Fragen Sie hierzu Ihren Fachhändler Schließen Sie keine Telefonleitungen an den RJ 45 Stecker an An diesen darf nur Sicherh...

Page 21: ...ware Installation Das TPG 125 ermöglicht bis zu zwölf Netzwerkdruckern die Kommunikation mit ThinPrint Servern Gehen Sie wie folgt vor 1 Verbinden Sie das Netzwerkkabel RJ 45 mit dem TPG 125 2 Verbinden Sie das Netzkabel mit dem TPG 125 ...

Page 22: ...Adresse des TPG 125 ermitteln und bei Bedarf eine frei definierbare IP Adresse im TPG 125 speichern InterCon NetTool installieren und starten 22 TPG 125 finden IP Adresse ermitteln 23 IP Adresse ändern 23 Der Client der Drucker und das TPG 125 müssen demselben lokalen Netzwerksegment zugeordnet sein InterCon NetTool installieren und starten Gehen Sie wie folgt vor 1 Laden Sie die Installationsdate...

Page 23: ...P Adresse aus dem für ZeroConf reservierten Adressbereich 169 254 0 0 16 gegeben erscheint es in der Geräteliste unter dem Filter ZeroConf Weisen Sie dem TPG 125 eine IP Adresse zu siehe IP Adresse ändern 23 IP Adresse ändern Für die vereinfachte Installation und Konfiguration der Netzwerkgeräte sind Assistenten Wizards in dem InterCon NetTool implementiert Für TPG 125 steht der IP Assistent zur V...

Page 24: ...G 125 konfiguriert und überwacht werden Gehen Sie wie folgt vor 1 Öffnen Sie Ihren Browser 2 Geben Sie als URL die IP Adresse des TPG 125 ein Das TPG Control Center wird im Browser dargestellt Falls das TPG Control Center nicht angezeigt wird überprüfen Sie die Proxy Einstellungen Ihres Browsers Detaillierte Informationen zur Konfiguration des TPG 125 entnehmen Sie der Online Hilfe des TPG Control...

Page 25: ...Quick Installation Guide de 25 ...

Page 26: ... Quick Installation Guide The latest version of the EC declaration of conformity can be downloaded from the homepage of SEH Computertechnik GmbH http www seh technology com services ce notifications html ...

Page 27: ...Quick Installation Guide 27 ...

Page 28: ...tacts and Information Sales Contacts and Information Downloads http www seh technology com support http www seh technology com sales http www seh technology com services downloads html 2016 SEH Computertechnik GmbH All trademarks registered trademarks logos and product names are property of their respective owners This product uses Open Source Software For further information please contact http w...

Reviews: