![SEFRAM SP260B User Manual Download Page 19](http://html1.mh-extra.com/html/sefram/sp260b/sp260b_user-manual_1233381019.webp)
8
Specifications
1-1 General Specifications
Dimensions :
82 mm (W) x 208 mm (L) x 41 mm (H)
Weight :
360 grams (including battery)
Power requirement :
9Vx1 battery
Auto power Off :
The meter automatically turns
the power off after powering up and no operation
for 35 ± 10minutes.
Battery life (based on Alkaline Battery) :
45 hours
Maximum Conductor Size :
35mm
LVD :
EN61010-1, EN61010-031, EN61010-2-032
EMC :
EN61326-1
Installation Category :
CAT.III. 600V, CAT.II. 1000V for Jaw.
ɛġ
The circuits directly connected to Low-voltage
installation.
ɜġ
The building installation.
ɝġ
The source of the Low-voltage installation.
1-2 Environmental Conditions
Indoor Use.
Maximum operating altitude :
2000m (6562ft)
Operating temperature :
0°C ~ 30°C,
ʀ
80%RH
ġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġ
30°C ~ 40°C,
ʀ
75%RH
ġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġġ
40°C ~ 50°C,
ʀ
45%RH
Storage temperature :
-20 to +60°C, 0 to 80% RH (no batteries).
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C
Pollution Degree :
2
Shock vibration :
MIL-PRF-28800F for A class 2 Instrument
Drop Protection :
4 Feet Drop to hardwood on concrete Floor
Type of sensing :
Hall effect sensing for AC and DC