6.

 

Specifications 

MODEL 

SC-VTD0001A (Transmitter) 

Video IN 

CVBS 1.0Vp-p, 75Ω Term. 

Transmission Bandwidth 

8MHz   

Data LED 

Tx: Green/ Rx: Yellow 

Transmission Distance 

Max. 1 km (with RG-6) 

Connection Port 

Video IN: BNC-F   
Video OUT: BNC-F 
DATA: RS-485/ Half Duplex, T. Block   
Alarm In/Out:   

Input 1CH/ Output 1CH 

Power 

AC 24V, DC12V/ 200mA 

Temperature/Humidity 

-10

  ~ +50

  / 0 ~ 80% 

Case Body / Weight 

Aluminum / 130g   

Dimension (mm) 

75(W) 

  60(H) 

  25(D) 

 

MODEL 

SC-VRD0001A (Receiver) 

Video Out 

CVBS 1.0Vp-p, 75Ω Term. 

Power 

AC 24V, DC12V/ 200mA   

Data LED 

Tx: Green/ Rx: Yellow 

Transmission Distance 

Auto Adjustment 

Connection Port 

Video IN: BNC-F 
Video OUT: BNC-M Harness (60cm) 
DATA: RS-485/ Half Duplex, T. Block   
Alarm In/Out:   

Input 1CH/ Output 1CH 

Temperature/Humidity 

-10

  ~ +50

  / 0 ~ 80% 

Case Body / Weight 

Aluminum / 140g   

Dimension (mm) 

75(W) 

  60(H) 

  25(D) 

 

7.

 

Precautions 

 

Please turn the power OFF prior to the installation of the device. 

 

The  data  error  can  be  occurred  where  the  installation  circumstances  are 

harsh enough such as the higher voltage, container belts, etc. 

 

Do  not  install  or  use  these  units  in  a  humid,  hot  or  hazardous  explosive 

environment without suitable and adequate protection. 

 

Do  no  expose  these  units  to  magnetic  materials,  high  frequency  radio 

waves. 

 

Avoid exposing the units to direct sunlight or into an unstable environment. 

 

Don’t drop the product or subject it to shock. 

 

Don’t modify or disassemble the product. 

 

The  installation  should  be  made  by  a  qualified  service  person  and  should 

conform to all local codes. 

 

The transmission cable has to be used “Standard Coaxial Cable such as RG-
59,  RG-6,  RG-11,  etc.”  only.  Please  use  BNC  connector  when  connecting 

the coaxial cable to the transmitter and the receiver units. 

If there is any malfunction in the device, please contact your distributor 

immediately.

 

Summary of Contents for SC-VCD0001A

Page 1: ...VIDEO DATA TRANSMISSION OVER SINGLE COAX CABLE SC VCD0001A SC VTD0001A SC VRD0001A User s Manual SC VTD0001A SC VRD0001A ...

Page 2: ...sen by the user You can use this product easier and more conveniently if you use the function of the product only after reading this operating instruction carefully CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol withi...

Page 3: ... directional data communication Bi directional Input and Output of alarm signals via separated alarm In Out port Long distance transmission up to MAX 1km with RG 6 Saving infrastructure cost Built in distance level switch for optimum video quality Installation improvement cost saving 25 30 Maintaining high quality video interference immunity Easy installation with BNC harness Surge lighting protec...

Page 4: ... indicator Green it flickers when it transmits the data Yellow it turns on when the power is on and it flickers when it receives the data Power input both 12VDC and 24VAC input are available Please note that there is no in the power input port Notes Please do not connect in parallel the RS 485 terminals of the transmitter SC VTD0001A Please use one transmitter for each receiver The alarm signal is...

Page 5: ... ON ON Auto detect None ON ON ON Resistance of the Termination Mode SW No 4 Disconnected Default OFF Connected 120 OHM ON Notes Please turn the power OFF after changing the switch SW and then turn it ON The auto detection is available with 1200 2400 4800 9600 only The size of packet should be lower than 21 bite 2P Terminal Block connect the power adapter 24VAC 12VDC 4P Terminal Block 2P for alarm ...

Page 6: ...ⅹ 60 H ⅹ 25 D 7 Precautions Please turn the power OFF prior to the installation of the device The data error can be occurred where the installation circumstances are harsh enough such as the higher voltage container belts etc Do not install or use these units in a humid hot or hazardous explosive environment without suitable and adequate protection Do no expose these units to magnetic materials hi...

Page 7: ... we give you free repair service according to the warranty certificate We charge you with the fee of parts and service despite of free warranty service period Any breakage made without care such as Breakage or trouble made by natural disaster Breakage or trouble made by breaking the product guide or manual Breakage or trouble made by wrong power voltage or frequency When you want to reassemble for...

Page 8: ...0 06 6 S Su un ni il l T Te ec ch hn no op pi ia a 4 44 40 0 S Sa an ng gd da ae ew wo on n D Do on ng g J Ju un ng gw wo on n G Gu u S Su un ng gn na am m S Si i G Gy ye eo on ng gg gi i D Do o K Ko or re ea a T TE EL L 8 82 2 0 0 3 31 1 7 77 77 7 3 35 50 08 8 F FA AX X 8 82 2 0 0 3 31 1 7 77 77 7 3 35 51 12 2 E EM MA AI IL L o ov ve er rs se ea as s s ss sc cc ct tv v c co om m h ht tt tp p w ww...

Reviews: