48
Focus Meter function
Focus Meter represents the optimum and current focus status(depth) in numerical values
The focus depth is represented in numerical values between 255 and 0. Adjust the optimum and current
focus depth to be matched.
Current
Value
Optimum
Value
This value depends on camera or lens types.
Viewer App. Functions
CRC Error Count measures the number of CRC errors in HD/EX/3G-SDI mode.
HD/3G-SDI Mode
EX-SDI Mode
CCR
C :
TIME
:
000
00 : 00 : 00
YCR
C :
000
XCR
C :
TIME
:
000
00 : 00 : 00
When HD/3G-SDI is entered, CCRC and YCRC values will be displayed. For EX-SDI input, XCRC value will
be displayed.
To activate this function, press the Set button once after connecting the camera
1
To initialize the values, press the Set button for two seconds during CRC measurement.
2
To terminate this function, press the Back button.
3
CRC Error Count function