-17-
12A4A4-00023E-5
7-3
Installation Specification
Item
Specification
Grounding
Grounding resistance of 100Ω, 2mm
2
[0.0062inch
2
] or thicker
wire, or your country’s applicable standard.
Structure
Protection Structure: IP65 *
1
(Front side only when mounted to panel)
Installation : Panel mounting
Cooling Method
Natural Convection
Weight
App. 700g
Exterior Measurement
192(W) x 137(H) x 36(D) mm
Panel Cut
183.5
+
0.5/-0
(W) x 128.5
+
0.5/-0
(H) mm
※
1
Protection structure of front surface when installed in a panel. It has been tested to verify compliance but
does not guarantee for all environmental use. Especially for oils defined in the test, in cases where
prolonged exposure to vaporized oils or cutting fluids with especially low viscosity, oil might enter to front
area through area where touch screen has lifted and may need special measurements. Please check the
installation environment prior to the use of EMG7.
Also, gaskets that have been used for a long time, or gaskets that have once been applied to panels, the
original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to
replace the gasket regularly.