background image

 A6 dp 

4 Connectors/Indicators 

 

 

 

 

 

 

 

 

 

 

 

4.2

 

Connectors 

XLR connectors (1) 

The  A6  dp  should  be  connected  with  a  standard  symmetrically  wired  XLR  cable.  To  connect  the 

input signal to further devices, use the male XLR Loop thru connector. To obtain full power perfor-

mance from the system, the signal source should be able to provide a minimum of 6 dBu distortion 

free output voltage. 

PowerCon blue (2) 

Power supply input voltage 110-230 VAC. This connector provides the function of an on-off switch. 

After powering on (turn the connector to the right until it locks), the systems starts up and is ready 

for use after approximately 3 seconds. Avoid repeatedly switching the system on and off, particular-

ly when it is operating. 

PowerCon grey (3) 

110-230  VAC  loop-through  connector.  This  connector  is  to  be  used  when  multiple  active  loud-

speakers  are  to be  provided  with power  from  one  source. Please  observe  carefully  the  maximum 

power capacity of the power source. 

 

The  nominal  power  consumption  of  the  A6  dp  under  full  power  is 

0.55 A  (measured  with  pink  noise,  Crest  Factor  8).  Transient  peaks 

can,  however,  cause  much  higher  momentary  power  drain.  Observe 

carefully  the  nominal  power  consumption  when  connecting  the  loud-

speaker(s)  to  the  power  source,  and  observe  carefully  the  cut-off 

current of the safety circuit breakers. We recommend using the loud-

speaker on power circuits with circuit breakers with C characteristic. 

 

Summary of Contents for 00260/dp

Page 1: ...User Manual A6 dp Version 3 2 18 05 2020 ...

Page 2: ...s 8 4 4 Status indication 8 5 Operation 9 5 1 Starting up 9 5 2 Selecting a bank 9 5 3 Setting level 10 5 4 Recalling presets 10 5 4 1 Preset Bank 1 Compatibility Mode 10 5 4 2 Preset Bank 2 Default Settings 11 5 5 Reprogramming of dp speakers with preset audio files 12 5 6 Locking the buttons 12 6 Technical specifications 13 7 Declaration of conformity 14 ...

Page 3: ...imize disruptive noise The default state of the integrated DSP controller is the standard configuration as described in this manual Custom presets can be installed by the user but must be programmed with the LPI Loud speaker Programming Interface by the manufacturer The preset file is a custom audio file which is simply played into the audio input of the controller In this manner individual config...

Page 4: ... power connected This can damage or destroy magnetic storage devices The PowerCon loop through connector is under power when the device is in operation Observe all relevant safety regulations at all times General safety precautions The installation and de rigging of this equipment should only be car ried out by appropriately qualified and experienced personnel and according to all relevant safety ...

Page 5: ...void operating in envi ronments below 5 C or above 40 C Be aware of the possibility of condensation forming inside the housing due to rapid changes in temperature Allow the loudspeaker to adjust to ambient temperature before operation Leave the device switched on if operating in unfa vorable conditions To prevent overheating do not operate the loudspeaker in the direct vicinity of strong heat sour...

Page 6: ...A6 dp 4 Connectors Indicators 6 4 Connectors Indicators 4 1 Connection panel PowerCon grey 3 XLR connectors 1 PowerCon blue 2 ...

Page 7: ...r approximately 3 seconds Avoid repeatedly switching the system on and off particular ly when it is operating PowerCon grey 3 110 230 VAC loop through connector This connector is to be used when multiple active loud speakers are to be provided with power from one source Please observe carefully the maximum power capacity of the power source The nominal power consumption of the A6 dp under full pow...

Page 8: ...ion Mute LED Lights red when the system is muted press the Set button in Status Mode or in technically critical conditions Limit LED Lights yellow when the limiter is limiting one or more amplifier chan nels Signal LED Lights green when a signal of more than 20 dBu is present The LED still lights up when the system is muted Power LED Lights when the system is powered up ...

Page 9: ...in up to 3 banks To change banks press and hold the Mode button whilst the loudspeaker is switched on 1 Press and hold the Mode button 2 Connect the power cable PowerCon blue 3 Corresponding LEDs blink to indicate the chosen bank 4 Release the Mode button When the power cable is connected the level and or preset LED lamps blink to indicate which bank is selected The level LED blinks to indicate th...

Page 10: ...s bank contains a Compatibility Mode The presets are acoustically compatible with A6 dp sys tems that are not fitted with the DPLM DSP controller Flat Preset for single application or in combination with a subwoofer e g G Sub 1501 dp HP 120 Flat preset with a higher cut off frequency for the high pass filter for combination with a subwoofer The higher cut off frequency allows a higher maximum soun...

Page 11: ...th a subwoofer The higher cut off frequency allows a higher maximum sound pressure level to be achieved Voice Flat preset with an additional high shelf filter that provides a high fre quency boost This setting is intended for applications in which speech intelligibility is particularly important Low Boost Based on the preset Flat with a low frequency boost This setting is useful in full range appl...

Page 12: ...ollows 1 Use a mini jack XLR stereo cable to connect the headphone output to the XLR input of the self powered box Use only one of the XLR connectors 2 Mute the box by pressing the Set button in Status Mode The Mute LED lights up The DSP controller can only receive data in the muted state 3 Make sure your computer s volume is set to 100 4 Load the wav file received from SEEBURG acoustic line into ...

Page 13: ... 90 x 60 rotable Max Splay Angle Connectors Neutrik XLR in out Neutrik PowerCon in out Handles 1 x Rigging flying points 2 x M10 7 x M8 35 mm pole mount Weight 16 8 kg Size height x width x depth 60 6 x 36 0 x 34 0 cm Order No 00260 dp The technical data sheet and further information about possible applications for the system and available accessories can be downloaded at the following Internet ad...

Page 14: ...996 classes E1 to E4 DIN EN 55103 2 1996 classes E1 to E4 Declared by Winfried Seeburg SEEBURG acoustic line GmbH Place and date Senden 01 01 2018 Legally binding sign ____________________________________________ The attachments constitute part of this declaration This declaration certifies conformity with the listed guidelines but does not guarantee any product characteristics The safety precauti...

Page 15: ...ic line Produkte sind nur für den gewerblichen Einsatz bestimmt All specifications are current at the time of publishing but are subject to change SEEBURG acoustic line Produktions und Vertriebs GmbH Auweg 32 D 089250 Senden Freudenegg Fon 49 0 7307 97 00 0 Fax 49 0 7307 97 00 29 www seeburg net info seeburg net ...

Reviews: