Page 1: ...INSTALLATION MANUAL ST PTZMINI IR10XTA High Speed Intelligent IR Dome PTZ Color Camera This is a 12 volt DC camera Copyright North American Cable Equipment ...

Page 2: ...g flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to different persons The exclamation point within an equilateral triangle is intended to alert the user the presence of important operating and maintenance ...

Page 3: ...ts of the video camera to Avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera All electrical connections to the dome should be made in strict accordance with the attached labels and wiring instructions in this manual and in accordance with all local and national electrical codes Failure to do so may damage the dome beyond repair and void the warra...

Page 4: ...surface you are planning to use for attaching the dome can adequately support the weight of the device and mounting hardware 9 Protect this device against lighting storms with proper power supplies surge arrestors and other protective precautions 10 Refer all servicing to SecurityTronix service personnel Servicing is required when the device has been damaged in any way when liquid traces are prese...

Page 5: ...re qualified to do so 14 During usage the user should abide by all electrical safety standards and adhere to electrical specifications for the operation of the dome The control cable for RS485 communications as well as the video signal cables should be isolated from high voltage equipment and high voltage cables 1 Carton Contents IR Speed dome 1pc Wall mount bracket 1pc Screws kit 1pc User manual ...

Page 6: ...ts 256 Pattern scan 4 Scan Patterns each can record 100 actions Tour scan Up to 30 presets Speed and dwell time can be set Rotation range Horizontal 360 Vertical 180 auto reverse Rotation speed Horizontal Vertical Min 0 01 Max 300 s Communications PELCO D and PELCO P OSD Full screen menu Temperature control system Optional Power supply DC12V Material Aluminum plastic for indoor use only Environmen...

Page 7: ... Soft Addressing The camera comes from the factory with the default settings of Address 1 Baud Rate 2400 Protocol Pelco D To Change the settings use a PTZ controller set the above settings to access the camera s menu by calling Preset 95 then use the menu as indicated in TABLE 3 3 on page 7 of this manual Dome camera dimensions ...

Page 8: ... is connected the camera will perform a self test function by panning and tilting the camera as well as testing zoom After the self test the camera will display the Protocol PTOL Baud Rate COMM and Address ADDR as shown in the diagram below PTOL PELCO D COMM 2400 N 8 1 ADDR 1 ...

Page 9: ...s stored There are a few exceptions such as the preset numbers which are reserved for special functions as listed in the table below To CALL a preset in the camera consult the manual for the specific PTZ controller you are using for how to call a preset For instance on a SecurityTronix ST PTZMINI KB controller the button sequence to CALL preset 1 on a camera is Press 1 press PRE Preset point funct...

Page 10: ...UP Screen display settings RESTORE FACTORY DEFAULT Restore the factory default setting REBOOT SYSTEM System restart EXIT Exit the OSD menu setting SYSTEM INFORMATION SYSTEM INFORMATION Menu function descriptions COM 2400 N 8 1 Displays the camera s current Baud Rate ADDRESS 1 Displays the camera s current Address PROTOCOL PELCO D Displays the camera s current Protocol PRESETS 256 Displays the curr...

Page 11: ... address Make sure to set the PTZ controller to the new address to regain control of the camera Access to the internal DIP switches requires extensive disassembly of the camera It is highly recommended to use soft addressing MOTION MOTION Menu function descriptions SET FRAME SCAN Set the left and right limit points for a LR scan POWER UP Set which action the camera performs on boot up PARK TIME Ho...

Page 12: ...te the PTZ controller to select the left limit position Press IRIS button to confirm the current position of the left limit and the menu will prompt to set the right limit position below SET FRAME SCAN Menu function descriptions RIGHT LIMIT POSITION IRIS OPEN TO CONTINUE Operate the PTZ controller to select the right limit position Press IRIS button to confirm and return to the previous menu CLEAR...

Page 13: ...erform pattern scan 4 CRUISE Perform the cruise scan of preset points PARK ACTION This menu sets which action the camera should perform if it sits idle no user input for a predetermined amount of time PARK ACTION Menu function descriptions NONE Don t perform any action AUTO SCAN Perform continuous scanning action RANDOM SCAN Perform intermittent scanning action FRAME SCAN Perform area L R scanning...

Page 14: ...HE STARTING POSITION PRESS IRIS OPEN TO CONTINUE Use the joystick or keyboard to move the camera to the starting position and press the IRIS key to continue PATTERN Menu function descriptions STORAGE USED 1 Operate the PTZ controller to begin recording movements The count starts at 1 and records up to 100 movements Press IRIS key to save the motion and return to the previous menu 3 9 CAMERA Lens s...

Page 15: ...tions IR MODE AUTO ON IR light is always on OFF IR light is always off AUTO IR light is switched on and off automatically IR ON SENS Sets brightness level at which the IR LEDs will turn on Range 81 254 IR OFF SENS Sets brightness level at which the IR LEDs will turn off Range 81 254 BACK Return to the previous menu EXIT Exit the menu setting 3 12 DISPLAY SETUP DISPLAY SETUP Menu function descripti...

Page 16: ... in the vicinity The picture appears smeared i The power supply voltage level may be unstable Try another power supply ii Ensure the cables are correctly connected and of the right impedance 75 ohms Other interference may require the use of a SecurityTronix ground loop isolation filter Power is on but the controller does not work i Check to make sure the DIP switches or software addressing are all...