V2.0 7-31-12
20
z
Preset Number Setting
)
Procedure:
1. Call preset point 95 to enter the main menu.
2. Use Up/Down P/T to choose
[PANTILT SETTING]
and press
[OPEN]
to confirm the selection
and enter preset set menu.
3. Under
[PANTILT SETTING]
choose the
[PANTILT SETTING]
sub-menu
and press
[OPEN]
to confirm the selection.
4. Under
[PANTILT SETTING]
choose
[PRESET NUMBER]
menu to enter to the preset point
setting, and the parameter will blink.
5. Use Up/Down P/T to choose a preset number.
6. Press
the
[OPEN]
key to save and exit. Press the
[CLOSE]
key to exit directly without saving.
Note: If the preset point already contains data, the dome camera will call the position to
alert you that the preset will be written over.
z
TITLE SETTING
)
Procedure:
1. Under
[PANTILT SETTING]
choose
[TITLE]
for entering into the title change menu, “Edit title
of the preset point” will be shown on the screen and the parameter will blink.
2. Use Up/down P/T to set the characters of the preset name.
3. Press
the
[OPEN]
key to save and exit. Press the
[CLOSE]
key to exit directly without saving.
z
SET NEW PRESET
)
Procedure:
1. Call preset point 95 to enter the main menu.
2. Up/Down cursor to choose
[PANTILT SETTING]
, press
[OPEN]
to confirm the selection and
enter pan set menu.
3. Under
[PANTILT SETTING]
choose
[PANTILT SETTING]
menu, press
[OPEN]
to confirm the
selection.
4. Under
[PANTILT SETTING]
choose
[SET NEW PRESET]
to enter into the preset point
setting. The display will show “Press IRIS OPEN”. First move the camera to the position you
would like to set for the preset, and then press IRIS CLOSE.
Instruction: The preset point number should be selected first before defining, displaying
and deleting the preset point or editing the title.
SEQUENCE SETUP
Individual preset points can be strung together to create a sequence, also known as a “tour”. Each
sequence can contain up to 32 preset points and each preset can have the dwell time set
individually.
PANTILT SETTING SEQUENCE SETUP
z
SEQUENCE NUMBER
【PANTILT SETTING
】
【PRESETS SETUP
】
→【SEQUENCE SETUP
】
【PATTERN SETUP
→ SEQUENCE NUMBER :
001
DEFAULT DWELL :
001
EDIT SEQUENCE
RUN CONTINUOUSLY
DELETE CURRENT