background image

v1.0  12/20/11 

4.  WIRING CONNECTIONS 

 

a. 

Connect the power supply’s DC plug to the camera’s power port. 

b.  Connect the camera to the monitor with a 75

 coaxial video cable. 

c.  Connect powe

r supply’s AC plug to a suitable AC power outlet. 

d.  Adjust the lens direction according to the required surveillance area and environment. 

 

     

              

          

 

 
 

5.  TROUBLESHOOTING 

a.  No picture after applying power 

– (i) check all plugs and cables are securely connected 

to the proper connectors; (ii) ensure your power supply is providing the correct voltage 
and current. 

b.  The picture has ripples 

– (i) check to see if the power supply is experiencing AC ripple, 

if so a filter may be required; (ii) determine if the monitor is faulty; (iii) determine if other 
peripheral equipment is causing ripple and if so make the necessary adjustments. 

c.  The picture background continuously changes color 

–  a fluorescent lamp’s magnetic 

field  may  cause  color  roll,  therefore,  reduce  the  number  of  fluorescent  lamps  or 
increase the distance between the camera and the lamps. 

d.  The  picture  appears  smeared 

– (i) the power supply voltage level may be unstable, 

therefore,  try  another  power  supply;  (ii)  ensure  the  cables  are  correctly  connected 
and/or the cables are of the correct impedance. 

e.  Other interference may require a Securitytronix ground loop isolation filter. 

f. 

Additional troubleshooting assistance can be found on-line at 

www.securitytronix.com

 

in addition to support from Securitytronix sales engineers at 1-610-429-1511. 

 

 

 