background image

4.  WIRING CONNECTIONS

a.  Connect the power supply’s plug to the camera’s power outlet.

b.  Connect the camera to the monitor with a 75

Ω

coaxial video cable.

c.  Connect power supply’s AC plug to a suitable AC power outlet.

d.  Adjust the lens direction according to the required surveillance area and environment.

5.  TROUBLESHOOTING

a.  No  picture  after  applying  power  –  (i)  check  all  plugs  and  cables  are  securely

connected  to  the  proper  connectors;  (ii)  ensure  your  power  supply  is  providing  the
correct voltage and current.

b.  The  picture  has  ripples  –  (i)  check  to  see  if  the  power  supply  is  experiencing  AC

ripple,  if  so  a  filter  may  be  required;  (ii)  determine  if  the  monitor  is  faulty;  (iii)
determine  if  other  peripheral  equipment  is  causing  ripple  and  if  so  make  the
necessary adjustments.

c.  The picture background continuously changes color – a fluorescent lamp’s magnetic

field  may  cause  color  roll,  therefore,  reduce  the  number  of  fluorescent  lamps  or
increase the distance between the camera and the lamps.

d.  The picture appears smeared  – (i) the power supply voltage level may be unstable,

therefore,  try  another  power  supply;  (ii)  ensure  the  cables  are  correctly  connected
and/or the cables are of the correct impedance.

e.  Other interference may require a SecurityTronix ground loop isolation filter.

f. 

Additional troubleshooting assistance can be found on-line at

www.securitytronix.com

in addition to support from SecurityTronix sales engineers at 1-610-429-1511.

V1.0  4/22/13

 

4