User Manual of Network Fisheye Camera
90
(Normally Open) and NC (Normally Closed). Edit the alarm name (optional).
3.
Check the checkbox of Enable Alarm Input Handling to enable the function.
4.
Set the arming schedule
.
Refer to
Task 2: Set Arming Schedule for Motion
Detection in Section 5.6.1.
5.
Set the linkage method. Refer to
Task 3: Set Linkage Method for Motion
Detection in Section 5.6.1.
6.
(Optional) You can copy your settings to other alarm inputs.
7.
Click
Save
to save the settings.
Note:
Alarm input settings vary according to the camera model.
5.6.4
Configuring Alarm Output
Steps:
1.
Enter the Alarm Output Settings interface:
Configuration > Events > Basic Event > Alarm Output
2.
Select one alarm output channel in the
Alarm Output drop-down list.
3.
(Optional) Input the alarm output name in the text field.
4.
The
Delay
time can be set to 5sec, 10sec, 30sec, 1min, 2min, 5min, 10min or
Manual
.
The delay time refers to the time duration that the alarm output remains
in effect after alarm occurs.
5.
Set the arming schedule
.
Refer to
Task 2: Set Arming Schedule for Motion
Detection in Section 5.6.1.
6.
(Optional) You can copy the settings to other alarm outputs.
7.
Click
Manual Alarm
to trigger an alarm manually. Click
Clear Alarm
to cancel
the alarm.
8.