2 of 4
4
Close and lock front panel.
Now follow the
Activation Guide
to create
an account and begin using Ascent.
INSTALLATION COMPLETE!
N
QUICK START
GUIDE
© 2018 Security Brands, Inc. All rights reserved.
Before going forward,
double check wiring and
ensure unit has power!
For additional wiring
options, see
Page 3
.
STOP!
2
2
0
1
5
Make sure gate path is clear, then
key in temporary code
2012
on
keypad and con
fi
rm gate opens.
Adding and deleting codes is done through
Summit Control and
NOT
from the keypad!
RELAY A
J4
RELAY B
J5
12–24 VAC/DC
POWER
J3
J8
J9
J12
DIGITAL INPUTS
3
Connect wires
Feed wires through back of
unit and connect as shown.
If you will not be using the 12-V AC/DC adapter,
please go to
Page 4
and follow the procedure,
Using a Third-Party Power Source
.
Do not exceed 24 VAC/DC! Failure to choose a
compatible power source can damage unit!
CAUTION!
Ascent Power and Relay Terminals
12–24 VAC/DC
POWER
Gate Operator / Door Opener
POS. (
+)
NEG. (
–)
CO
M
RADIO
CO
M
REVERSE LOOP
CO
M
OPEN
ST
OP
CLOSE
12-V AC/DC Adapter
(Model PS-12DC1 included)
The GROUND terminal is optional unless
required by local code(s). If using, please
connect to earth ground or equivalent.
OR
Relay B can be wired to a second device
in the same manner.
FREE EXIT
CO
M
+ –
N/C
CO
M
N/O
N/C
CO
M
N/O
POS. (
+)
NEG. (
–)
GND
# 1
GND
# 2
GND
# 3
Third-Party 12–24-VAC/DC
Power Source
Model
16-X2
QSG-16X2-EN Rev. D (6/2018)
If plugging into duplex outlet,
remove screw from outlet plate,
and secure with included screw.
Additional wiring diagrams
can be found on
Page 3
.
Consult gate operator or
door opener manual for
exact connections.
Terminals vary widely
across manufacturers
and models.