background image

Data sheet 

6 / 6 

T 811 156 en a, 10.11.2015  Rd 

USB502 

First edition: 10.09.2014  Rd 
Reference document: 7002870-02 
The product specifications contained in this document are subject to change without prior notice.  
© Copyright by Securiton 

Article numbers / spare parts 

Short designation 

Swiss art. no. 

Art. no. 

USB 502-1 standard base  

123.265244 

30-4100005-01-01 

USB 502-1 MC (multicolour) 

123.985295 

30-4100005-91-01 

USB 502-2 base for false ceilings 

123.265246 

30-4100005-02-01 

USB 502-3 base for wet rooms 

123.265248 

30-4100005-03-01 

USB 502-4 base for mounting in concrete 

123.265250 

30-4100005-04-01 

USB 502-5 base for raised floors 

123.265252 

30-4100005-05-01 

USB 502-6 standard base 

123.265254 

30-4100005-06-01 

USB 502-6 MC (multicolour) 

123.985297 

30-4100005-96-01 

USB 502-7 Ex-i base for Ex zones 

123.265256 

30-4100005-07-01 

USB 502-8 Ex-i standard base for Ex zones 

123.265301 

30-4100005-08-01 

USB 502-20 standard base with illuminated ring 

123.249467 

20-2100019-01-01 

USB 502 support point terminal 

322.265240 

31-3100002-01-01 

177 mm protective ring 

123.231835 

3110470 

158 mm protective ring MC (multicolour) 

988.943584 

3110464 

DNP 502 (detector number plate) 

322.265242 

31-3100001-01-01 

DNP 521/531 detector number plate (optional) 

322.215880 

3110320 

Replacement sealing ring for USB 502-3 

--- 

3210296 

 
 
 

Technical data 

Power consumption 

(only USB 502-20) 

Typically 0.9 mA 

Illuminated ring 

(only USB 502-20) 

Colour 
Visibility 
Flashing 

frequency 

Light intensity 

 

Red (on alarm transmission) 

360° 

1.2 to 3 Hz 

approx. 1 cd 

Area of application 

Dry and wet rooms (see section “Mounting / installation”) 

Protection type (with inserted detector) 

See detector data sheet 

Ambient temperature 

-

25 … +70 °C 

USB 502-20: -

25 … +60 °C 

Ambient  humidity (continuous,  without condensa-
tion) when ≤ 34 °C 

10 ... 95 % rel. humidity 

Ambient humidity  
(continuous, without condensation) when > 34 °C  

max. 35 g/m³ 

min. 10 % rel. humidity 

Installation type (depending on variant) 

Surface mounting/flush mounting 

Dimensions 

See dimensioned drawing 

Housing material 

PC-ABS, TPE 

Housing colour 

Electric white (similar to RAL 9003) 

Connection 

Screw terminals, max. 2.5 mm² 

Weight (gross, including packaging) 
USB 502-1, USB 502-6 and USB 502-8 Ex-i 
USB 502-2 
USB 502-3 
USB 502-4 
USB 502-5 
USB 502-7 Ex-i 
USB 502-20 

 

approx. 90 g 

approx. 210 g 
approx. 189 g 
approx. 179 g 
approx. 229 g 
approx. 200 g 
approx. 100 g 

VdS approval 

Included with detectors 

(except USB 502-5, -7 Ex-i, -8 Ex-i) 

 

Summary of Contents for 988.975850

Page 1: ...O gas pre signal adjustable in the range of 20 to 320 ppm does not correspond to any standard CO gas maintenance alarm Fault messages Ageing optical fault voltage supply fault NTC short circuit and interruption CO gas sensor fault EEPROM memory fault overtemperature Key features of the CCD 573X are Digital signal processing Alarm threshold tracking Temperature compensated smoke element Signature a...

Page 2: ...s USB 502 4 Base for flush mounting in concrete USB 502 6 Standard base surface mounting without loop con tact USB 502 20 Standard base with illuminated ring without loop contact The specifications in the data sheets shall apply for installation de tector base series USB 502 Connection The maximum number of detectors on an address able loop has to be calculated It must take into ac count power con...

Page 3: ...etector self test that automatically subjects the detectors to an extensive electronic function check They are also equipped with automatic soiling compensation It is nevertheless necessary that all active sensors of the detector undergo a physical and functional check on site for their set modes of operation at regular intervals Securiton recommends the following Maintenance and inspection work s...

Page 4: ...on 2 conductor technology Operating voltage range incl modulation amplitude 7 to 31 VDC Power consumption When quiescent When alarm Alarm LED active Alarm output active 5 mA 1 mA 0 1 mA Typically 150 µA max 190 µA Max 20 mA pulsed Max 2 5 mA Max 7 5 mA 2 1 mA 0 7 mA Alarm output2 3 Output voltage Output voltage short circuit proof 5 0 VDC 1 V 0 3 V Min 5 mA min 1 0 mA min 0 1 mA Line isolator Rate...

Page 5: ...5 base variants green terminal block are equipped with a loop contact This means terminals 2 and 3 are connected and are opened automatically when the detector is in serted On the 573 and MMD detector series the connection and thus also the ring is closed again when the detector is removed On the 563 detector series the connection remains open and the control panel signals a fault The USB 502 6 US...

Page 6: ... the cable must be fitted with a drip nose before it reaches the base This applies in particular to flush mounting in stallations in wet rooms garages etc In such applications the bases must be mounted next to the flush mounting concrete box and openings C or D must be used for inserting the cable see Fig 4 The base has no strain relief The cable entry can be made ei ther from the rear through the...

Page 7: ...ith the integrated claw fittings or using two screws fastening holes Insert the protective ring covers the screws afterwards together with the detector Fig 6 USB 502 2 installation Installation notes for USB 502 3 The USB 502 3 base variant is specially designed for use in wet rooms and consists of Mounting box with four cable inserts PG 13 5 and stopper plugs USB 502 1 standard base Sealing ring ...

Page 8: ... and USB 502 8 Ex i base variants are permit ted for use in Ex zones in combination with the MMD 130 Ex i multi criteria detector The MMD 130 Ex i fire detector may only be oper ated with the USB 502 USB502 and using a Z787 Z787F or GTW 01 02 The safety barrier and GTW must be installed in the safe area The fire detector base is intended for surface mounting The Ex i detector is secured in the bas...

Page 9: ...rved during connection Connection examples Fig 8 USB 502 connection with line technology Fig 9 USB 502 connection with addressable loop technology Dimensioned drawings Fig 10 USB 502 1 USB 502 6 USB 502 8 Ex i Fig 11 USB 502 2 Fig 12 USB 502 3 Fig 13 USB 502 4 Fig 14 USB 502 5 Fig 15 USB 502 7 Ex i Fig 16 USB 502 20 GND 1 3 4 5 6 2 SHLD L1 L2 1 3 4 5 6 2 SHLD GND L1 L2 SHLD 3 K Final detector GND ...

Page 10: ...ring MC multicolour 988 943584 3110464 DNP 502 detector number plate 322 265242 31 3100001 01 01 DNP 521 531 detector number plate optional 322 215880 3110320 Replacement sealing ring for USB 502 3 3210296 Technical data Power consumption only USB 502 20 Typically 0 9 mA Illuminated ring only USB 502 20 Colour Visibility Flashing frequency Light intensity Red on alarm transmission 360 1 2 to 3 Hz ...

Reviews: