Suggested wiring diagram
4
Required setting of alarm panel
The connected alarm panel must have following settings:
– Phone communication should be enabled in the alarm centre
– DTMF (Tone) dialing should be selected
– A minimum 4 digit phone number should be set for dialing (anything is acceptable, e.g. 1111)
– Object identifier should be set
– Contact ID (Full) should be selected
The device will accept the Contact ID reports from alarm panel as a monitoring receiver, and forward
them to IP monitoring receiver. Only after the reporting was acknowledged by monitoring station,
the acknowledge signal will be transmitted to alarm panel.
5
Status signals
With the status LED
❼
, the device can display these basic statuses.
Signals
Device status
Flashing RED
Connecting to network / SIM or network failure after 1 minute
Flashing GREEN
Idle state ( Device is ready, waiting for report from alarm panel)
Continuous GREEN
Communication with alarm panel in progress
Flashing RED & GREEN
Low signal strength, below 30%