SECURECOM SC-GSM M2 Installation Manual Download Page 4

SC-GSM M2 

manual v2.0

 

4 EN

 

2

 

Structure 

 

 

 

 

 

 

TIP/RING Communication terminals, generated phone line output

  

Simulated PSTN line for connection to TIP/RING alarm panel input terminals 

 

Power supply terminals

  

Power requirements: DC 9-30V / 300mA 

 

Alarm contact inputs

  

Triggered to negative supply (with dry contact) 

 

SIM card holder

 

Type: 2FF/mini SIM 

 

USB mini B connector for configuration

 

 

 

GSM antenna connector, SMA type

 

 

 

Status signaling LEDs 

Summary of Contents for SC-GSM M2

Page 1: ...SC GSM M2 manual v2 0 1 EN S SC C G GS SM M M M2 2 Alarm system communicators that generate individual SMS messages and alarm calls via GSM network from Contact ID reports Installation manual v2 0...

Page 2: ...Structure 4 3 Suggested wiring diagram 5 4 Required setting of alarm panel 5 5 Status signals 5 6 Settings 6 6 1 Standalone mode 7 6 2 Transparent mode 7 6 3 Contact inputs events setting 8 6 4 Gener...

Page 3: ...ode the device is capable of GSM voice calls with phone line simulation The device can connect the alarm system to the user via a mobile call or can be used as a simple phone line in other application...

Page 4: ...TN line for connection to TIP RING alarm panel input terminals Power supply terminals Power requirements DC 9 30V 300mA Alarm contact inputs Triggered to negative supply with dry contact SIM card hold...

Page 5: ...will accept the Contact ID reports from alarm panel as a monitoring receiver and forward them to IP monitoring receiver Only after the reporting was acknowledged by monitoring station the acknowledge...

Page 6: ...evice to the PC and select the appropriate serial port then push the Connect button For example Once connected device settings can be found on the following interface Attention To validate the changes...

Page 7: ...filter does not take into account the Zone and Partition values To trigger an SMS message and alert CALL for a given event you need to select the phone numbers to be notified and enter the text of th...

Page 8: ...dividually 6 4 General settings In this window you can change the parameters related to the operation of the communicator SIM PIN the PIN code of the inserted SIM card must be entered if PIN code requ...

Page 9: ...ndow The administration window of SecurecomConfigurator contains the following basic information about the device The function of the administration icons is as follows Type of connection and operator...

Page 10: ...GSM 2G GSM850MHz EGSM900MHz DCS1800MHz PCS1900MHz Supply voltage 9 V 30 V DC Rated current 100 mA Maximum current 300 mA Operating temperature 20 C 70 C Dimensions 40x80x15 mm 8 Device package content...

Reviews: