Before installation

When Installing this Product:

1.  This document provides instructions for the installation and electrical wiring of SecureAire’s Whole-

Home Air Purification System.

2.  Read these instructions carefully as failure to comply can damage the product or cause a hazardous 

condition. 

3.  Review the specifications provided to ensure that it is suitable for your application.
4.  The installer must be a trained, experienced mechanical and electrical technician.
5.  After the installation is complete, please complete the system start-up procedures to ensure correct 

installation and operation of the product. 

What’s Inside the Box:

 SecureAire Platinum Air Purifier

 8-foot electrical plug-in cord

Installation Tools Needed:

Phillips screwdriver

Custom sheet metal fittings

Wire cutter

Sheet metal cutting tools

Wire stripper

Locking pliers or clamps

Wire crimper

Sheet metal screws

Drill

Silicone sealant

SecureAire Product Model Numbers and Airflow Rating:

Model Numbers

Maximum Airflow (cfm)

ACS1620-PLT

1200

ACS2020-PLT

1400

ACS1625-PLT

1400

ACS2025-PLT

2000

Replacement Filter Part Numbers:

Filter Size (HxWxD in inches)

Platinum Series Filter Part Number

16x20x2

R1620-PLT

20x20x2

R2020-PLT

16x25x2

R1625-PLT

20x25x2

R2025-PLT

Summary of Contents for Platinum ACS1620-PLT

Page 1: ...on selecting SecureAire s most advanced Whole Home Air Purification System SecureAire s patented design utilizes ACTIVE Particle Control technology proven to capture and remove airborne contaminants from your home while INACTIVATING killing viable airborne pathogens including bacteria viruses and mold Safe Healthy and Clean Indoor Air ...

Page 2: ...ving space including particulates pathogens and VOCs STEP 1 CONDITION Particles entering the SecureAire System become electrically CONDITIONED STEP 2 COLLISION Conditioned Particles are forced to COLLIDE gaining mass in the process STEP 3 CAPTURE INACTIVATE Collisions make particles easier to CAPTURE within the filter media Once CAPTURED any viable pathogens will be INACTIVATED or killed STEP 4 TR...

Page 3: ...lation is complete please complete the system start up procedures to ensure correct installation and operation of the product What s Inside the Box SecureAire Platinum Air Purifier 8 foot electrical plug in cord Installation Tools Needed Phillips screwdriver Custom sheet metal fittings Wire cutter Sheet metal cutting tools Wire stripper Locking pliers or clamps Wire crimper Sheet metal screws Dril...

Page 4: ... oil and electric forced air furnaces and central air conditioning systems Before Installation continued Airflow considerations are vital to the heating and cooling system s performance longevity and safety as well as the performance of the SecureAire Air Purifier Industry standards are established to ensure proper design and installation of this product and the associated ductwork Please see the ...

Page 5: ...nstall beneath furnace The SecureAire Air Purifier is mounted horizontally where return enters from below 3 Upflow with closet install The SecureAire Air Purifier is mounted vertically on furnace between furnace and louvered return air opening in closet door 4 Counterflow with the SecureAire Air Purifier is mounted horizontally in return plenum just above furnace and opposite heating plenum 5 Coun...

Page 6: ... installation plan and airflow direction Temporarily place the SecureAire Air Purifier on the floor orienting as it will be when installed Temporarily insert and remove the SecureAire Air Purifier to make sure there is adequate clearance for easy removal if that is ever necessary If the installation of the unit requires the airflow direction to be reversed this is easily accomplished by removing t...

Page 7: ...ire grids A Remove the front plastic panel via the four 4 Philips head screws on the top of the panel and the 4 Phillips head screws on the bottom of the panel Gently slide out the three 3 wire grid assemblies and set them aside The cabinet is now ready to be connected to the heating or cooling equipment and the return ductwork Installing the SecureAire Air Purifier Upflow Furnace Example ...

Page 8: ...re supplied on the plug in power cord supplied with the SecureAire unit If connecting directly from another source the technician must install wire ring lugs on the power wires that connect to the SecureAire terminal block The supply line voltage power source is 120V 60 Hz A Remove the 2 two Phillips head lock screws from the cabinet s top access panel B If the existing wiring connection out of th...

Page 9: ...locking pliers to help hold the cabinet in place during drilling Step Six Connect the cabinet to the return air plenum A If needed install turning vanes to help distribute air equally over the full surface of the upstream side of the SecureAire Air Purifier See the Appendix Application Recommendations for details B Connect the SecureAire Air Purifier securely to the return air ductwork Fasten with...

Page 10: ...p Nine Connect power to the power supply Installation of the SecureAire Air Purifier should be performed by a licensed electrician or a certified HVAC technician Electrical wiring must comply with applicable local codes and standards Wire ring lugs must be used when connecting input line voltage to the terminal block The supply line voltage power source is 120V 60 Hz When using the supplied plug i...

Page 11: ...te Unlike other electronic air filtration or air cleaning products this hissing sound does not indicate that ozone or any other potentially unsafe byproduct is being created The SecureAire Air Purifier creates no harmful byproducts B Turn off the SecureAire Air Purifier and the ON OFF switch light turns off indicating the entire SecureAire power supply is powered off The SecureAire Air Purifier is...

Page 12: ...e properly installed Joints in all sheet metal connections are sealed All sheet metal connections are complete Original furnace filter has been removed and blower compartment is cleaned Replace any equipment access doors removed during the installation Run the furnace or cooling system through one complete cycle to ensure system is operating Consider asking the homeowner if they would like to prog...

Page 13: ...e system s filter which is easily accomplished using the following steps Step One Turn off the system power button Step Two Unlatch and remove the front door Step Three Carefully remove the used filter Gently pull out the used filter without disturbing the accumulated dirt on the filter and place the filter in a large plastic bag for disposal Installing the SecureAire Air Purifier Upflow Furnace E...

Page 14: ...the new replacement filter Insert the new filter making sure that the replacement filter seats against back of the SecureAire cabinet and the airflow arrows on the filter are pointing in the direction of the airflow Step Five Re attach the front door and turn system power on The SecureAire Air Purifier filter replacement is now complete ...

Page 15: ...0 14 SecureAire Air Purifier Dimensions Part Numbers Height Width Depth ACS1620 PLT 18 20 6 75 ACS2020 PLT 22 21 6 75 ACS1625 PLT 18 26 6 75 ACS2025 PLT 22 26 6 75 SecureAire Filter Dimensions Nominal Part Number Height Width Depth R1620 PLT 16 20 2 R2020 PLT 20 20 2 R1625 PLT 16 25 2 R2025 PLT 20 25 2 Model Width Height Depth ACS1620 PLT 20 18 6 75 ACS1625 PLT 26 18 6 75 Model Width Height Depth ...

Page 16: ... Drop Curves Standards and Approvals The SecureAire Whole Home Air Purification System has been tested and verified to meet or exceed the following UL 867 Electrical Standard CSA C22 2 No 187 09 Electrical Standard Revision Table Rev Description ECO Date Approval B Second Release 7 8 2019 JC Safe Healthy and Clean Indoor Air To Learn More Visit our website at www secureaire com residential SecureA...

Reviews: