background image

9

Receiver status LED

LED indication

Unit mode

Button usage

Solid Off LED
Flashing Network LED

Unit is currently 
excluded from the 
network

Off and On - No 
function
Network - Network 
function

Flashing On LED 
(Green) 3s only Solid 
Off LED 

Unit has been 
successfully included 
on the network

Off and On - No 
function
Network - Network 
function

Solid OFF LED

Unit is reflecting the 
status Off the relay 
unit. The output is 
OFF.

Or, unit has finished 
the include process.

Or, unit has been 
included and has just 
been powered up on
the mains

Off and On - switches
channel relay off or on
respectively.

Network - Network 
function

This unit has three buttons and three LEDs - ON, OFF and Network (from 
top to bottom) that are used as follows:-

Summary of Contents for SSR303

Page 1: ...SSR303 One Channel 3 Amp Switch Rx Only Z Wave User and Installation Instructions 1...

Page 2: ...2...

Page 3: ...mmands or Binary Switch SET commands This SSR303 will act as a repeater once included into the Z wave network providing an alternative communication route for units which otherwise would not be within...

Page 4: ...Off using the On Off buttons on the SSR303 receiver as a local override If the override is used to override the system when it is functioning correctly then the override will be cancelled by the next...

Page 5: ...retaining screws located on the underside the wall plate should now be easily removed Once the wall plate has been removed from the packaging please ensure the SSR303 is re sealed to prevent damage fr...

Page 6: ...he wall then secure the plate into position The slots in the wall plate will compensate for any misalignment of the fixings Wall Box Mounting The wall plate may be fitted directly on to a single gang...

Page 7: ...The receiver is mains powered and requires a 3 Amp fused spur The recommended cable size is 1 Omm2 The receiver is double insulated and does not require an earth connection an earth connection block i...

Page 8: ...8 SSR303 internal wiring diagram The receiver has voltage Free contacts Fit link between L 2 for mains voltage applications Please ensure that all installations comply with current IEE regulations...

Page 9: ...lly included on the network Off and On No function Network Network function Solid OFF LED Unit is reflecting the status Off the relay unit The output is OFF Or unit has finished the include process Or...

Page 10: ...Solid Network LED Unit is in failsafe mode and the relay output is OFF Off and On No function Network Network function Solid ON LED Solid Network LED Unit is in Failsafe mode and the relay output has...

Page 11: ...s flashing on the SSR303 if not follow the steps in Disconnecting from a network first Put the 3rd party controller into inclusion mode Press and hold the network button on the SSR303 until the ON LED...

Page 12: ...wn as exclusion in Z wave terminology Put the 3rd party controller into exclusion mode Press and hold the network button on the SSR303 The SSR303 has been excluded from the network when the Network LE...

Page 13: ...ssociate the SSR303 with a control group or just to determine the device and command classes supported This can be done at any time but will not provide any indication to the operator Z wave Repeater...

Page 14: ...Z Wave Command Classes Support Description Manufacturer Specific Command Class Secure Manufacture ID Version Command Class Provides the version number of the Software Thermostat Mode Command Class Onl...

Page 15: ...s no failsafe mode Multi Channel Command Class Ver 2 This command is used to independently access the two channels available on the SSR303 Note All command classes are version 1 unless otherwise state...

Page 16: ...re Range 0 40 C Double Insulated Rated Impulse voltage Cat 1 1500v Pollution control Degree2 Enclosure protection IP30 Case material Thermoplastic flame retardant Dimensions 86mm x 86mm x 36 25mm Part...