Secure Home SH-9910AU Installation And Operating Instructions Manual Download Page 4

4

201115-01

UP

FINAL ASSEMBLY

1.  Double check all wiring connections.

2.  Verify  the  rubber  gasket  is  properly  seated 

around the edge of the canopy extension (see 

Figure 6).

3.  Align the center hole on the fixture canopy 

with the center hole on the canopy extension 

and attach using the mounting bolt removed 

in step 1 of Installation (see Figure 6).

 

IMPORTANT:

• If wall mounted, make sure the fixture is 

mounted with the sensor below the lamp 

heads.

• If  eave  mounted,  mount  the  fixture  with 

sensor facing away from the house wall (see 

Eave Installation Information for important 

sensor orientation information).

4.  Push the rubber plug firmly into place (see 

Figure 7).

5.  Caulk around top half of canopy extension 

with silicone weather sealant (see Figure 7).

Terminal Block

From Fixture

From AC Source

WIRING

1.  Connect the house wires to the terminal block 

according to diagram (see Figure 4). Make 

sure all screws on terminal block are tightened 

securely.

2.  Remove the strain relief cover and place the house 

wires across the strain relief (see Figure 5).

3.  Replace  the  strain  relief  cover  and  tighten 

securely. 

Note:

 Be careful not to overtighten 

and damage the wiring.

 WARNING: Turn power off at circuit 

breaker or fuse. Place tape over circuit 

breaker switch and verify power is off at 

the fixture.

Green/Yellow

Green/Yellow

Blue

Blue or Black

Brown

Red or Brown

Figure 4

UP

Terminal Block

House Wiring

Screw

Strain Relief 

Cover

Figure 5

Figure 6

Mounting 

Bolt

Rubber Gasket

Fixture Canopy 

(Lamp 

heads and sensor not 

shown for clarity)

Summary of Contents for SH-9910AU

Page 1: ...nting Bolt Owner s Manual REQUIREMENTS The light control requires 230 volts AC If you want to use Manual Mode the control must be wired through a switch It is illegal for persons other than a licensed electricianorpersonauthorizedbylegislation to work on fixed wiring or other electrical installations Before installation record the model num ber listed inside the fixture Attach receipt in case of p...

Page 2: ... higher than 2 4 meters 8 feet aiming the sensor down will reduce coverage distance Do not use dimmer switches or timers with this fixture Thesensoronthislightfixturedetects motion bythemovementofheatacrossthecoveragearea How ever following are examples of objects that also produce heat and can cause the sensor to trigger Pools of Water Air Conditioners Dryer Vents Animals Heating Vents Automobile...

Page 3: ...e When positioningthecanopyextensionformounting do the following Keep the mounting tabs level Make sure the canopy extension is turned as shown in Figure 2 Makesurethehousewiringislocatedbehind or below the rubber grommet 3 Useapowerdrilltodrillintothewalltoprovide a suitable mounting for the screws Canopy extension mounting screws are not included Use4mmdia 8G x30mmscrews Care should be taken to ...

Page 4: ...7 5 Caulk around top half of canopy extension with silicone weather sealant see Figure 7 Terminal Block From Fixture From AC Source WIRING 1 Connect the house wires to the terminal block according to diagram see Figure 4 Make sure all screws on terminal block are tightened securely 2 Removethestrainreliefcoverandplacethehouse wires across the strain relief see Figure 5 3 Replace the strain relief ...

Page 5: ... up period before it will detect motion When first turned on wait 1 1 2 minutes 2 Set ON TIME switch to TEST RANGE dial to Midway position Clamp Screw Controls Controls Controls Figure 7 Figure 8 Figure 9 Canopy Extension Rubber Plug Caulk Upper Half of Canopy Extension Bottom of Sensor ON TIME 10 5 1 TEST MIN MAX RANGE Figure 10 3 Adjust the lamp holders by loosening the lock nuts but do not rota...

Page 6: ...iontimethecontrolwillbeintheAUTO mode 4 Loosen the clamp screw in the sensor ball joint and gently rotate the sensor 5 Walk through the coverage area noting where you are when thelightsturnon also the LED will flash several times when motionisdetected In TESTmode lightwill stayonfor5secondsaf termotionhasstopped and then turn off Move the sensor head up down or sideways tochangethecoverage area Ke...

Page 7: ...le traffic 2 Range is set too high 1 Re aim sensor Reduce range 2 Reduce range Light stays on continuously 1 A lamp head is positioned to close to the sensor or pointed at nearby objects that cause heat to trigger the sensor 2 The sensor may be picking up a heat source like an air vent dryer vent or brightly painted heat reflective surface 3 Light control is in Manual mode 4 Sensitivity is set too...

Page 8: ... or return the Unit to you Exclusions This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than an authorised installer to repair dismantle reinstall or move the Unit to anot...

Reviews: