IMPORTANT SAFETY AND INSTALLATION INFORMATION

Before installing security light, read all instructions carefully and keep owner’s manual for future 

reference.

• WARNING: To prevent electric shock, please ensure that power is disconnected before installation.

• WARNING: Risk of fire. Do not aim the lamp heads at a combustible surface within 1 meter (3 feet).

• This fixture must be connected to a 230V-240V ~ 50Hz power source.

• The fixture must be properly grounded.

• This fixture is designed for outdoor installation and should be mounted to a wall or eaves.

• To achieve best results, this fixture should be mounted 2.4 meters (8 feet) above the ground. 

Note:

 If fixture 

is mounted higher than 2.4 meters (8 feet), aiming the sensor down will reduce coverage distance.

• Do not use dimmer switches or timers with this fixture.
The sensor on this light fixture detects “motion” by the movement of heat across the coverage area. How-

ever, following are examples of objects that also produce heat and can cause the sensor to trigger:

• Pools of Water 

• Air Conditioners

• Dryer Vents 

• Animals

• Heating Vents 

• Automobile Traffic

If you suspect that a heat source of this type is triggering the sensor, reduce the sensitivity.
The sensor on this fixture is more sensitive to the movement of heat moving across the coverage area 

and less sensitive to the movement of heat directly towards it.

Note:

 Light fixture and sensor should be mounted as shown above when installed (depending upon 

type of installation).

 

Wall Mount 

Eave Mount

 

Least Sensitive 

 Most Sensitive

Sensor

Motion

Motion

Summary of Contents for SH-9910AU

Page 1: ...nting Bolt Owner s Manual REQUIREMENTS The light control requires 230 volts AC If you want to use Manual Mode the control must be wired through a switch It is illegal for persons other than a licensed electricianorpersonauthorizedbylegislation to work on fixed wiring or other electrical installations Before installation record the model num ber listed inside the fixture Attach receipt in case of p...

Page 2: ... higher than 2 4 meters 8 feet aiming the sensor down will reduce coverage distance Do not use dimmer switches or timers with this fixture Thesensoronthislightfixturedetects motion bythemovementofheatacrossthecoveragearea How ever following are examples of objects that also produce heat and can cause the sensor to trigger Pools of Water Air Conditioners Dryer Vents Animals Heating Vents Automobile...

Page 3: ...e When positioningthecanopyextensionformounting do the following Keep the mounting tabs level Make sure the canopy extension is turned as shown in Figure 2 Makesurethehousewiringislocatedbehind or below the rubber grommet 3 Useapowerdrilltodrillintothewalltoprovide a suitable mounting for the screws Canopy extension mounting screws are not included Use4mmdia 8G x30mmscrews Care should be taken to ...

Page 4: ...7 5 Caulk around top half of canopy extension with silicone weather sealant see Figure 7 Terminal Block From Fixture From AC Source WIRING 1 Connect the house wires to the terminal block according to diagram see Figure 4 Make sure all screws on terminal block are tightened securely 2 Removethestrainreliefcoverandplacethehouse wires across the strain relief see Figure 5 3 Replace the strain relief ...

Page 5: ... up period before it will detect motion When first turned on wait 1 1 2 minutes 2 Set ON TIME switch to TEST RANGE dial to Midway position Clamp Screw Controls Controls Controls Figure 7 Figure 8 Figure 9 Canopy Extension Rubber Plug Caulk Upper Half of Canopy Extension Bottom of Sensor ON TIME 10 5 1 TEST MIN MAX RANGE Figure 10 3 Adjust the lamp holders by loosening the lock nuts but do not rota...

Page 6: ...iontimethecontrolwillbeintheAUTO mode 4 Loosen the clamp screw in the sensor ball joint and gently rotate the sensor 5 Walk through the coverage area noting where you are when thelightsturnon also the LED will flash several times when motionisdetected In TESTmode lightwill stayonfor5secondsaf termotionhasstopped and then turn off Move the sensor head up down or sideways tochangethecoverage area Ke...

Page 7: ...le traffic 2 Range is set too high 1 Re aim sensor Reduce range 2 Reduce range Light stays on continuously 1 A lamp head is positioned to close to the sensor or pointed at nearby objects that cause heat to trigger the sensor 2 The sensor may be picking up a heat source like an air vent dryer vent or brightly painted heat reflective surface 3 Light control is in Manual mode 4 Sensitivity is set too...

Page 8: ... or return the Unit to you Exclusions This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than an authorised installer to repair dismantle reinstall or move the Unit to anot...

Reviews: