IMPORTANT SAFETY AND INSTALLATION INFORMATION
Before installing security light, read all instructions carefully and keep owner’s manual for future
reference.
• WARNING: To prevent electric shock, please ensure that power is disconnected before installation.
• WARNING: Risk of fire. Do not aim the lamp heads at a combustible surface within 1 meter (3 feet).
• This fixture must be connected to a 230V-240V ~ 50Hz power source.
• The fixture must be properly grounded.
• This fixture is designed for outdoor installation and should be mounted to a wall or eaves.
• To achieve best results, this fixture should be mounted 2.4 meters (8 feet) above the ground.
Note:
If fixture
is mounted higher than 2.4 meters (8 feet), aiming the sensor down will reduce coverage distance.
• Do not use dimmer switches or timers with this fixture.
The sensor on this light fixture detects “motion” by the movement of heat across the coverage area. How-
ever, following are examples of objects that also produce heat and can cause the sensor to trigger:
• Pools of Water
• Air Conditioners
• Dryer Vents
• Animals
• Heating Vents
• Automobile Traffic
If you suspect that a heat source of this type is triggering the sensor, reduce the sensitivity.
The sensor on this fixture is more sensitive to the movement of heat moving across the coverage area
and less sensitive to the movement of heat directly towards it.
Note:
Light fixture and sensor should be mounted as shown above when installed (depending upon
type of installation).
Wall Mount
Eave Mount
Least Sensitive
Most Sensitive
Sensor
Motion
Motion