Radio Key
®
RKDT-SA-M/SA-S Operating Guide
Secura Key
20
Disable Timed Antipassback.
Place the unit in the Program Mode (see Page 9). Press SET
TIMER then VOID, finally press ENTER.
(SET TIMER)
(ENTER)
(VOID)
+ +
Configure the Relay
The relay is set at the factory to be normally open and to close
upon presentation of a valid card or tag or upon activation of
the remote open (Request to Exit) input. It may be changed to
normally closed or to SecuRelay™ operation. A normally open
relay is used for a “fail-secure” electric lock or door strike and
to trigger a gate operator. A normally closed relay is used for
“fail-safe” devices such as magnetic locks. The Secura Key
SecuRelay™ (sold separately) is a remote intelligent relay
used to prevent entry when the access control unit is physically
attacked. (NOTE: When placed in the SecuRelay™ mode the
“Remote Open” input is disabled.) To configure the relay, put
the unit in the Program mode (See Page 9). Press THRU two
times. Then press either the “6”, “7” or “8”. Press ENTER.