Secura Key RK-65K Operating Manual Download Page 12

(New Password - 54321)

(Re-type New Password - 54321)

(ENTER)

(THRU)

(THRU)

Radio Key

®

 RK-65K                                           Operating Guide

Secura Key 

 

      9

            +     5     +     4     +      3     +     2     +     1     +

        +   5    +   4    +   3    +   2    +   1   +  

Lost or forgotten Password (RK65K/RK100M)

If the password is lost or forgotten, it can be restored to the 
factory default (12345).  Remove the Radio Key

®

 RK-65K 

unit from the wall and disconnect power. With the Data 1 line 
(white wire) temporarily connected to the Remote open line 
(brown wire), restore power. The factory default (12345) is 
now in effect. The LED will fl ash alternately Red and Green. 
While this is occurring, set the Facility Code or Codes in the 
reader (see below). Remove power and reconnect the unit for 
operation, restore power and remount the unit. This procedure 
will NOT delete any transponders from reader’s memory. 

Setting Facility Code(s) (RK65K)

Before any cards are added to the RK-65K you must set the 
Facility Code or Codes. When a new reader is fi rst  powered 
up the LED should be fl ashing alternately Red and Green. This 
indicates that the unit is in the “Learn Facility Code” mode. 

Summary of Contents for RK-65K

Page 1: ...5K RK 65KS with RK100M instructions STAND ALONE PROXIMITY ACCESS CONTROL SYSTEM with DYNASCAN TECHNOLOGY 3321732 Operating Guide Rev C www SecuraKeyStore com 800 878 7829 sales securakeystore com U S...

Page 2: ...COPYRIGHT 2007 SOUNDCRAFT INC V060107 6451...

Page 3: ...5KS 4 Programming Radio Key RK100M 5 Handheld Programmer RK HHP Programming Deck RK PD1 6 Programming Steps 7 Programming Hints 13 Basic Operation 19 Converting to RK100M Mode 21 Warranty 28 Speci cat...

Page 4: ...page 18 The major components are shown in Figures 1 and 2 The Radio Key RK 65K Access Control Unit contains the CPU memory access relay and an internal reader It has a beeper and a bi color LED indica...

Page 5: ...Secura Key 2 Figure 1 Radio Key RK 65K RK 65KS Units NOTE All references to RK 65K also apply to the RK 65KS Figure 2 Programming Deck RK PD1 Hand Held Programmer RK HHP NOTE Programming sequences are...

Page 6: ...can order the same Facility Code specifying the starting number which will be one digit higher than your highest existing transponder If you use Format 201 these are shipped from stock and you may re...

Page 7: ...tags and cards are pre encoded and engraved at the factory with a Facility Site Code and an individual card ID number You must teach the RK 65K which Facility Code or Codes up to 10 it should recogni...

Page 8: ...ws you to assign a Transponder to each User ID Number 1 100 for programming purposes The User ID Number is associated with the individual person using the transponder Be sure to record the User ID Num...

Page 9: ...ng cards ENTER 7 SEVEN 0 ZERO 8 EIGHT 1 ONE 9 NINE 2 TWO THRU 3 THREE VALID 4 FOUR VOID 5 FIVE SET TIMER 6 SIX MODE Presenting these cards to the Radio Key RK 65K is equivalent to pressing the identic...

Page 10: ...the reader After you have completed a proper program sequence the unit will beep and the LED will ash green to indicate that the program instruction has been accepted A red light and a beep at the end...

Page 11: ...asswords are entered the unit will sound an alarm and display a red LED for 30 seconds then return to normal mode Change your Password RK65K RK100M Put the unit into the Program mode if necessary See...

Page 12: ...wn wire restore power The factory default 12345 is now in effect The LED will ash alternately Red and Green While this is occurring set the Facility Code or Codes in the reader see below Remove power...

Page 13: ...reader one at a time After you are nished allow the reader to time out and return to the Normal Mode before proceeding NOTE An invalid facility code will beep with no LED visible ADDING AND DELETING U...

Page 14: ...Then press Thru followed by the sequence of digits representing the highest transponder ID number Then press Enter For example to add transponders 1 through 10 to the system 1 1 0 Transponder number...

Page 15: ...numbertransponder Finally press Enter For example to delete transponders 1 through 10 1 1 0 Transponders 1 through 10 are now void Set the Latch Timer RK65K RK100M Put the unit into the Program mode S...

Page 16: ...have set an extended latch time but need to interrupt it follow this procedure Put the unit in Program Mode see Page 8 Then press Set Timer then 1 then Enter After the Program Mode expires present a...

Page 17: ...remote open input will activate the relay for the time the latch timer is set Mode 2 deactivates the unit No tag can activate the relay but the remote open input will activate the relay In mode 3 the...

Page 18: ...unit to the inactive locked mode the following sequence would be followed 2 To Exit Programming Mode Immediately RK65K RK100M Press MODE then 1 or 2 3 or 4 card to the unit Press ENTER This returns t...

Page 19: ...he Program Mode see Page 8 Press SET TIMER then press THRU Press the digits representing the maximum number of minutes you want antipassback to apply 01 99 Press ENTER Antipassback can be from one to...

Page 20: ...gate operator A normally closed relay is used for fail safe devices such as magnetic locks The Secura Key SecuRelay sold separately is a remote intelligent relay used to prevent entry when the access...

Page 21: ...nput is set at the factory as a Remote Open input Connecting the brown and the orange wire usually with a push button switch will activate the relay for the time set for the latch timer This input may...

Page 22: ...RK 65K Unit The Radio Key RK 65K Unit generates an RF eld which causes the Key Tag to transmit a unique Transponder ID Number back to the Unit If the Transponder ID Number is stored in memory the lat...

Page 23: ...open input is activated the relay will activate When the remote open input is deactivated the relay will return to the inactive state after the latch timer times out A green light and a beep indicate...

Page 24: ...0 users If you need to replace an existing RK100M or if you want a reader that uses random cards and tags you may convert this product to the RK100M mode as shown below In the RK100M mode some program...

Page 25: ...the system as described below RadioKey 100MallowsyoutoassignaTransponder toeachUserID Number 1 100 for programming purposes The User ID Number is associated with the individual person using the transp...

Page 26: ...r 12 the following sequence would be followed 1 2 Hold Key Tag or Card near unit Record the User ID Number and Transponder ID Number NOTE IfyouassignanewtranspondertoaUserIDNumberwhere another transpo...

Page 27: ...d on the Transponder then press ENTER For example to program a Transponder ID Number 995 into User ID Number 12 the following sequence would be followed 1 2 9 9 5 Record the User ID Number and Transpo...

Page 28: ...Transponders are already entered into the User ID Number range you have selected they will be overwritten For example to program ten transponders into User ID Numbers 1 through 10 the following sequen...

Page 29: ...quence of digits representing the desired ending User ID Number Finally press ENTER A green light and beep mean that the range of Transponders was deleted 1 1 0 Delete a Transponder by Presenting to R...

Page 30: ...s VOID Press THRU then press the sequence of digits representing the ID number printed on the Transponder Finally press ENTER A green light and beep means that the transponder was deleted For example...

Page 31: ...SIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED SECURA KEY SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OR MERCHANTABILITYAND FITNESS FORAPARTICULAR PURPOSE The remedies pr...

Page 32: ...40 mA Idle Wiegand Output Any Wiegand Format up to 40 bits Maximum Distance 500 Ft 5 or 6 conductor 20 gauge shielded cable Outputs SPST Solid State Relay 1A max 60 VAC or DC Normally open or normally...

Page 33: ...numbered only Card Key Tag Operation Passive Transmit Frequency 125 kHz Memory Non Volatile Latch Timer Programmable 0 25 sec to 18 hours or Toggle Mode Accessories RK HHP Hand held Programmer RK PD1...

Page 34: ...quipment off and on the user is encouraged to try to correct the interference by one or more or the following measures Reorient or relocate the receiving antenna Increase the separation between the eq...

Page 35: ...www SecuraKeyStore com 800 878 7829 sales securakeystore com...

Reviews: