5
Technical Specifications
Electrical
Current Withstand
30 A continuously
500 A for 1 second
Maximum voltage
600 V
Contact resistance
≤
2
m
Ω
Dielectric Withstand
3.0 kV RMS for 1 minute between adjacent
contact pairs and between any contact pair and
other metal parts
2.0 kV RMS for 1 minute between open con-
tacts when test plug is inserted
Voltage Impulse
3 positive and 3 negative impulses of 5 kV
peak, 1.2/50
µ
s, 0.5 J between adjacent contact
pairs and between all contact pairs and other
metal parts
UL94 Flammability Class
V-0
Enclosure Protection
IP20 without cover
IP50 with optional dust cover attached
ITS / STP has been classified as electromagnetically benign by the Guide for the
EMC Directive 2004/108/EC and is, therefore, excluded from the scope of the EMC
Directive.
ITS / STP meet or exceed all requirements from ANSI / IEEE C37.90-2005.
15