2. Configuration
tank
volume
Enter tank volume
in litres
Type of tank is shown
in upper left corner
Tank height „H“
Enter tank height
in cm
Type of tank is shown
in upper left corner
Offset
Distance between
sensor to the
maximum tank level
Distance measurement
for e.g. manhole pit or
mounting hole
Alarm
(min.)
Limit for alert in
percent
When Limit is reached
an alarm SMS will be
launched.
Alarm
(max.)
Limit for alert in
percent
When Limit is reached
an alarm SMS will be
launched.
Power safe
Default is 0, the
display is turned
off after 35 s
0 Default
1: continuous display
date
mm/dd
Current Date
Month and day
April 1st - 0401
date
year
Current year
e.g.:2009
Time
Current time
Hours and minutes
0757
Instant of time
Measurement
Time (daily)
e.g.: at 07:30 h
measurement is made
by LC200
GSM
Mode
GSM Mode
1 :GSM enable
0: GSM disabled
1
–SMS send according
to operated settings
GS sen
SMS frequencies
0= every 28th of each month
1 = every 7 days
2 = every 14 days
Tel.No.:
Receiver 1*
Telefon Number
Recipient No.1
Any modification
e.g.0167 78787787
or 0044 167 7878787
Tel.No.:
Receiver2*
Telefon Number
Recipient No. 2
First digit 0,
no second recipient
*) after last digit appears zero 0, press arrow button ▲ until no figure appears.
New Configuration on SMS function causes SMS messages for 7 days.
Throughout that time
no alarm message is sent.(only if the alarm is confirmed the second day)
Daily SMS:
To adjust the daily text message, press the button on the default display mode for longer than 10 seconds.
SETUP GS Day On on display appears. - The daily tank gauge mode is now active.