Security & Electronic Technologies
Seite 7
Maintenance, Troubleshooting, Service
The device does not need any maintenance.
Clean the inside of the sensor cone once a year with a dry cloth to avoid dirt and debris which could
influence the beam of the ultrasonic pulses.
Make a visual check of the batteries once a year.
If the device shows unexpected behaviour try to reset the instrument by using the reset button.
Check your installation (look at the instruction for installation).
If the problem persists contact our service team, or send the device to an authorised service facility.
If the device is damaged, remove it immediately from your tank and send it to an authorised service facility.
If the device is removed close the tank entry after that so that the vapours can´t escape.
Warranty
For the actual services and conditions see our home page
www.secu-tech.at
,
See the GTCS
– General Terms and Conditions of Sale.
Technical Specification
Power supply:
LC 100, LC 103
Batteries:
4x 1.5 V, Mignon, type AA, alkaline
Wattage:
during the measurement 19 mA
Energy-saving mode 0,45 mA
Battery life time:
typically 2 years in energy saving mode with min. 2000mA/h per battery,
symbol
“b“ for low batteries (ca. 20% rest)
LC101, LC 102
Mains adapter:
110 V AC / 6 V DC
Dimensions (w x d x h):
LC 100, 101, 102, 103
30 inch x 16,5 inch x 67 inch
Protection:
IP 20, for indoor usage only
Display:
LC-display 2,2 inch x 1,39 inch,
2 lines with 4 digits 1,47 mm and 1,55 mm high
Weight (mass):
0,49
– 1,37 lb depending on version
Material:
ABS, black, oil resistive
Measurement range:
7,5 inch
… 106,3 inch, 0 … 9999 gallons
Accuracy:
0,4 inch
Measurement interval:
Normal mode: one measurement every 23:45 hour
Operating temperature:
14°
– 120°F
Engineering Standards:
CE, ROHS
Offset Installation