Maintenance, Troubleshooting, Service 

 
The device does not need any maintenance. 
Clean the inside of the sensor cone once a year with a dry cloth to avoid dirt and debris which could 
influence the beam of the ultrasonic pulses. 
Make a visual check of the batteries once a year. 
If the device shows unexpected behaviour try to reset the instrument by using the reset button. 
Check your installation (look at the instruction for installation). 
If the problem persists contact our service team, or send the device to an authorised service facility. 
If the device is damaged, remove it immediately from your tank and send it to an authorised service facility. 
If the device is removed close the tank entry after that so that the vapours can´t escape. 
 

Warranty 

 
For the actual services and conditions see our home page 

www.secu-tech.at

See the GTCS 

– General Terms and Conditions of Sale. 

 

Technical Specification 

 

Power supply: 
 

LC 100, LC 103 
Batteries: 

4x 1.5 V, Mignon, type AA, alkaline 

Wattage:              

during the measurement 19 mA 

 

Energy-saving mode 0,45 mA 

 
Battery life time:   

typically 2 years in energy saving mode with min. 2000mA/h per battery,  

 

symbol 

“b“ for low batteries (ca. 20% rest) 

 
LC101, LC 102 
Mains adapter: 

110 V AC / 6 V DC 

 
Dimensions (w x d x h):  

LC 100, 101, 102, 103 

30 inch x 16,5 inch x 67 inch 

 

Protection: 

IP 20, for indoor usage only 

 
Display:

 

LC-display 2,2 inch x 1,39 inch,  

  

2 lines with 4 digits 1,47 mm and 1,55 mm high 

 

Weight (mass):                

0,49 

– 1,37 lb depending on version 

Material:

 

ABS, black, oil resistive 

Measurement range:

 

7,5 inch 

… 106,3 inch, 0 … 9999 gallons 

Accuracy:

 

0,4  inch 

Measurement interval:

 

Normal mode: one measurement every 23:45 hour  

Operating temperature:

  

14° 

– 120°F  

Engineering Standards:

   

CE, ROHS  

 

 
 
 
 
 
 
 
 
 
 
 
 

Offset Installation 

Summary of Contents for LC 100

Page 1: ...Operating Instruction LC 100 LC 101 LC 102 LC 103 Contactless tank content measurement in Inch and Gallons With room to fill detection 04 2013 LC E M 03_C SW 50 04 02 2016 LC EA M 01 SW 80 04 ...

Page 2: ...fore installing the LC device LC must not be installed in a hazardous environment and must not be used for the following liquids Gasoline Ethanol aggressive chemical products like acids and aggressive chemicals The LCD device has no features that prevents your tank from overfilling The LC provides no features against the tank becoming empty Please use only high quality batteries The manufacturer o...

Page 3: ...ation and the tank has a minimum entry of 1 5 inch ideally 2 BSP thread The mathematical calculation in this device is designed only for cylindrical and cubic tank shapes special shapes are not supported Only a specialist licensed company is allowed to modify the tank in case there is a need to drill or cut holes in the tank you lose the warranty and in case of damage you are personally liable Wra...

Page 4: ...d If no button is pushed after 35 sec LC change to power safe mode PS must be 0 Preparation LC 101 LC 102 Power supplied units Plug the power adapter into the power outlet 110 V Power Adapter and the outgoing cable into the side connector of the LC Unit 1 The installed software version is displayed 2 A measurement is taken 3 Unit display with standard configuration data appears Functionality Power...

Page 5: ...Button next Button Mode confirm next selection Tank content Gallons Tank height in inch Offset Activate display Enter tank volume in gallons Enter the height of the tank H in inch Distance from the sensor to the max level Tank type in upper left corner Tank type in upper left corner It s necessary i e for installation in a manhole pit Maximum 59inch 1 3 Get Actual Demand Data Press Mode Button for...

Page 6: ...tery replacement 2 2 Cable If the cable is carried out through a wall it requires a inch diameter hole to run the plug through it 2 3 Mounting on tank thread LC has 2 threads 1 Inch and 2 Inch Screw the device into the tank manufacturer opening provided for the fuel gauge We recommend the use of a Teflon tape Please screw the LC only with your hands force into the thread Over tightened screws may ...

Page 7: ...n t escape Warranty For the actual services and conditions see our home page www secu tech at See the GTCS General Terms and Conditions of Sale Technical Specification Power supply LC 100 LC 103 Batteries 4x 1 5 V Mignon type AA alkaline Wattage during the measurement 19 mA Energy saving mode 0 45 mA Battery life time typically 2 years in energy saving mode with min 2000mA h per battery symbol b f...

Page 8: ...nstalling the unit on the tank Hold the funnel opening in 90 angle against a smooth flat surface floor ceiling wall and do some test measurements Important These technical specifications can be changed any time by SECURITY ELECTRONIC TECHNOLOGIES GmbH Adress Aumühlweg 3 1 Place A 2544 Leobersdorf Telefon 43 2256 201 77 Fax 43 2256 201 77 11 Internet www secu tech at E Mail office secu tech at Tank...

Reviews: