Secu-tech LC 100 Operating Instruction Download Page 2

 

 

Contents 

General Instruction ........................................................................................................................................... 2

 

Safety Instructions............................................................................................................................................ 2

 

Product Description ......................................................................................................................................... 2

 

Instruction for installation ............................................................................................................................... 3

 

Checking the contents of delivery .................................................................................................................. 3

 

Operating Elements .......................................................................................................................................... 4

 

Preparation ........................................................................................................................................................ 4

 

1, Configuration ................................................................................................................................................ 5

 

Special information and error indications ..................................................................................................... 6

 

2, Installation Instruction ................................................................................................................................. 6

 

Start measurement ........................................................................................................................................... 6

 

Function Reset .................................................................................................................................................. 6

 

Maintenance, Troubleshooting, Service ........................................................................................................ 7

 

Warranty............................................................................................................................................................. 7

 

Technical Specification .................................................................................................................................... 7

 

Offset Installation.............................................................................................................................................. 7

 

For your tank data´s ......................................................................................................................................... 8

 

Notes .................................................................................................................................................................. 8

 

© SECURITY & ELECTRONIC TECHNOLOGIES GmbH ................................................................................ 8

 

 

Document: 02 2016 

LC AE M 01

 

General Instruction 

The LC is used for simple measurement of tank contents usually in poor visibility conditions.  The 
measurement is performed by means of ultrasound echo measurement. It measures the distance of the 
sensor to the surface of the liquid. The result is displayed in gallons and percent. The conversion of the 
measurement is based on the entered tank parameters. (See page 5 of the tank input parameters) 
The accuracy of the summary is based on the setting and the prevailing conditions at the tank. The LC has 
an accuracy of + \ - 1 inch at a distance of 7,5 inch up to 106,3 inches. 

Safety Instructions  

Please read this document carefully before installing the LC device. 
LC must not be installed in a hazardous environment and must not be used for the following liquids: 
Gasoline, Ethanol, aggressive chemical products like acids and aggressive chemicals. 
The LCD device has no features that prevents your tank from overfilling. 
The LC provides no features against the tank becoming empty. 
Please use only high quality batteries. The manufacturer of the equipment shall not be held liable for 
damages caused by batteries,

 

improper use and any resulting damages. 

  
Modifications of the product are prohibited. Service repair and maintenance shall only be done by the 
manufacturer or authorised service facilities. 

Product Description 

Main Advantages:

  

 

Tank capacity in gallons and volume in percent 

 

Available space in tank display ( how many gallons can be refuelled) 

 

Calculation of average daily consumption in gallons per day 

 

Supply in days 

 

Calculation  of  the  remaining  days  based  on  average  daily  consumption 

(only  displayed  after  the  5

th

  day 

following a reset or battery exchange)

 

 

3 different tank shapes are supported by appropriate calculations 

 

Simple and easy Installation 

 

No moving components in the tank 

 

Contactless measurement with ultrasonic pulses for maximum reliability 

Applications: 

 

Heating Oil Tanks 

 

Waste Oil Tanks 

 

Water Tanks  

 

Rainwater Tanks   

 

As replacement 

for mechanical gauge indicators… 

 
 

Summary of Contents for LC 100

Page 1: ...Operating Instruction LC 100 LC 101 LC 102 LC 103 Contactless tank content measurement in Inch and Gallons With room to fill detection 04 2013 LC E M 03_C SW 50 04 02 2016 LC EA M 01 SW 80 04 ...

Page 2: ...fore installing the LC device LC must not be installed in a hazardous environment and must not be used for the following liquids Gasoline Ethanol aggressive chemical products like acids and aggressive chemicals The LCD device has no features that prevents your tank from overfilling The LC provides no features against the tank becoming empty Please use only high quality batteries The manufacturer o...

Page 3: ...ation and the tank has a minimum entry of 1 5 inch ideally 2 BSP thread The mathematical calculation in this device is designed only for cylindrical and cubic tank shapes special shapes are not supported Only a specialist licensed company is allowed to modify the tank in case there is a need to drill or cut holes in the tank you lose the warranty and in case of damage you are personally liable Wra...

Page 4: ...d If no button is pushed after 35 sec LC change to power safe mode PS must be 0 Preparation LC 101 LC 102 Power supplied units Plug the power adapter into the power outlet 110 V Power Adapter and the outgoing cable into the side connector of the LC Unit 1 The installed software version is displayed 2 A measurement is taken 3 Unit display with standard configuration data appears Functionality Power...

Page 5: ...Button next Button Mode confirm next selection Tank content Gallons Tank height in inch Offset Activate display Enter tank volume in gallons Enter the height of the tank H in inch Distance from the sensor to the max level Tank type in upper left corner Tank type in upper left corner It s necessary i e for installation in a manhole pit Maximum 59inch 1 3 Get Actual Demand Data Press Mode Button for...

Page 6: ...tery replacement 2 2 Cable If the cable is carried out through a wall it requires a inch diameter hole to run the plug through it 2 3 Mounting on tank thread LC has 2 threads 1 Inch and 2 Inch Screw the device into the tank manufacturer opening provided for the fuel gauge We recommend the use of a Teflon tape Please screw the LC only with your hands force into the thread Over tightened screws may ...

Page 7: ...n t escape Warranty For the actual services and conditions see our home page www secu tech at See the GTCS General Terms and Conditions of Sale Technical Specification Power supply LC 100 LC 103 Batteries 4x 1 5 V Mignon type AA alkaline Wattage during the measurement 19 mA Energy saving mode 0 45 mA Battery life time typically 2 years in energy saving mode with min 2000mA h per battery symbol b f...

Page 8: ...nstalling the unit on the tank Hold the funnel opening in 90 angle against a smooth flat surface floor ceiling wall and do some test measurements Important These technical specifications can be changed any time by SECURITY ELECTRONIC TECHNOLOGIES GmbH Adress Aumühlweg 3 1 Place A 2544 Leobersdorf Telefon 43 2256 201 77 Fax 43 2256 201 77 11 Internet www secu tech at E Mail office secu tech at Tank...

Reviews: