background image

+

1

2

V

C

O

M

2

0

 V

A

C

P

G

M

1

P

G

M

2

GSV4M

+12V

 

DC

 external 

power supply

Load

20VAC

COM

+12V

PGM2

PGM1

PGM output wiring

3

Input

s

Normally open contact

(NC)

Normally closed 

contact

(NC)

Technical information

Overall dimensions L x W

Operating temperature:

120,0

 

x

 

63,5 mm

-10°C   + 50°C

 9 

years. A

Calculated life expectancy for communicator

 

at 40

 ambient temperature is

mbient temperature over 40

 may reduce life expectancy.

°C

°C

Maximum load ratings and electrical

 

characteristics

Maximum battery charging current:

DC voltage: 

+

0,

035

A

 9 - 14V

Maximum current 

into PGM1:

Maximum current 

into PGM2:

-0,05A

-

0,

05

Minimum AC voltage on 20 VAC

:

Current consumption

 (idle

 running

):

~

16

V

50mA

Maximum AC voltage on 

:

 

Note:

 higher than 

 V voltage can damage communicator.

20 VAC

~

22

~

22

V

Maximum current of  fast blowing fuse used in battery circuit: 

Current consumption

 (

within data transmission

):

3,15

A

365mA

Maximum current of  slow blowing fuse used in primary AC

:

 

Maximum AC power consumption

:

250mA

15

mA

Communicator is powered from independent power supply

Communicator is powered from control panel power supply

GSV4

M

Universal GSM / GPRS communicator

Wiring  manual 

Note:

 do not use +12V 

terminal for powering other 
devices, the ex12V 
DC power supply must be 
used.

Additional information

Firmware upgrade

Status LED

Required softwares:

  

Firmware Upgrade Tool v.1.xx

  

GSV4M Loader v.3.000

GSV4M

S1

 Status

 LED

Modem

 LED

Status LED:

  

Off –

 GSM network problem (SIM not active, 

poor signal strength, antenna not connected);
   1 flash 

 GSM signal strength: 

 

;

   2 flashes 

 GSM signal strength: 

 

;

   3 flashes 

 GSM signal strength: 

 

;

   4 flashes 

 GSM signal strength: 

 

;

   5 flashes 

 GSM signal strength: 

 

;

   On (2 seconds) 

 event is received (from 

PSTN dialer or keybus), input is triggered.

Upgrade steps:

1. Disconnect the communicator from power supply.
2. Press and hold S1 button.
3. Connect USB cable while holding S1 button.

4

. In order to upgrade the 

GSV4M

, double-click on the latest firmware 

upgrade file

 (for example: GSV4M   v.4.000c.dfu )

.

6. Follow the instructions in software Firmware Upgrade Tool to complete 
the firmware upgrade procedure.
7. Restore GSV4M settings to default values with a software GSV4M loader.
8. 

GSV4M firmware is now upgraded. You can disconnect GSV4M from the 

computer.

Modem LED

:

  

Off –

 modem problem;

   Flashing (0,5 second

s on, 

0,5 second

s off

 GSM network problem (SIM 

not active, poor signal strength, antenna not connected);
   Short flash every 2 seconds 

 registered on GSM network;

  

O

 

dialling or data transmission is in progress.

IN

1

GSV4

M

NO

C

O

M

IN

1

GSV4

M

NC

C

O

M

In order to program GSV4M connect device to computer using USB cable. Software GSV4M loader is used to program GSV4M 

communicator. It can be downloaded from out web page: www.secolink.eu. GSV4M loader automatically downloads the present settings 
from GSV4M when USB cable is connected. Carefully choose the GSV4M operation mode before starting the programming. Entered 
phone number, ticked setting checkbox and etc. are automatically saved in software (in temporal memory), but aren't automatically sent to 
GSV4M. Do not forget to send them to GSV4M when programming is finished. Entered settings also can be saved in file (press button 

Export template

).

GSV4M 

Loader software

GSV4M settings are split in different categories for easier programming:

Users

 – user phone numbers, dialling and messaging settings can be changed in this tab. User phone numbers must be entered starting with a country 

code, for e4466454xxxxx. Plus sign „

+

“ is automatically entered by software. If user wants to control GSV4M he should enter PIN during the call. If 

commonicator is not connected to other manufacturer control panel module keybus, user should enter PIN that is programmed in this tab. By default this PIN 
is 1111 and is common for all GSV4M users. If GSV4M is connected to other manufacturer control panel module keybus, user should enter the same PIN 
which is used to operate alarm system via keypad.

GPRS reporting

 - all settings related to reporting to monitoring station can be changed in this tab. GSV4M can send reporting to two receivers, in 3 diferent 

protocols.

Inputs

 - GSV4M has 6 inputs to trigger specific communications. It is possible to assign a specific Contact ID event or a simple text message to be sent 

when input is triggered.

Outputs 

– GSV4M has has two programmable outputs to activate in response to

Security settings 

– the GSV4M contains two diferent level security options: it is possible to limit the access to GSV4M GPRS settings only or limit the 

access to all GSV4M settings. Keep security password in safe place. 

GSM modem settings

 – in this tab is possible to enter SIM card PIN, review the information about GPRS communication, GSM signal strenght.

Phrases

 – all phrases that are used in SMS messages are stored in this tab. In order receive readable SMS with a actual zone, partition or user names it is 

necessary to fill all related fields. When communicator receives the report from PSTN dialer it is checking the phrase list and when received event element id 
numer matches it uses that phrase in SMS. 

Voice messages

 – this tab allows the voice message to be assigned to a zone. It is possible to choose any from 243 available voice files. GSV4M loader 

interface language must be the same as written on GSV4M communicator sticker.

Summary

 – all GSV4M settings can be reviewed and printed in this tab.

 user control commands via SMS, phone call.

Outputs control with a short call 

 if it is necessary to control GSV4M output without sending DTMF tone string or SMS command this can be don by 

entering users phone number phone number section of this tab and assigning output to number. In order to trigger the output user should call to GSV4M. 
User should hear the dialling tone and reject the call. This actions will trigger an output. Note: if user phone number is saved in users tab phone number list 
and user wants to control the GSV4M by sending DTMF tone string he should not reject the call and wait 5 seconds. After 5 seconds communicator will 
answer the call and will "ask" to enter PIN and hash.