Intruder  alarm  system

GSV4

Wiring  manual 

SAFETY  WARNINGS

The device must be installed in a place with limited access.

Please act according to your local rules and do not dispose of your unusable alarm system or its components   with other household 
waste. This product   utilization in EU is covered by European Directive   2002/96/EC.

The device uses two power supplies: main and back-up.

2V, 7Ah/20HR capacity, rechargeable hermetically sealed Lead-Acid battery.

Main power supply: a   power   transformer   with:
       - primary winding: ~230V, 50 Hz; 
       - secondary winding: ~20V, 1.5A, 50Hz.
Back-up power supply: 1

SECOLINK intruder alarm system GSV4 is compliant with   EN 60950-1 safety requirements.
Power supplies described above must comply with the EN 60950-1 safety requirements.
All devices connected to the intruder alarm system must comply with EN 60950-1 safety requirements.
Intruder alarm system is compliant with the essential requirements of Directives 1999/5/EC, 2004/108/EC and 2006/95/EC.
Intruder alarm system contains radio transceiver operating in GSM900/1800 bands.
Please read and follow these safety guidelines in order to maintain safety of operators and people around:
DO NOT use the intruder alarm system where it can interfere with other devices and cause any potential danger.
DO NOT use the intruder alarm system with medical devices.
DO NOT use the intruder alarm system in a hazardous environment.
DO NOT expose the intruder alarm system to high humidity, chemical environment, or mechanical impacts.

Additional 

automatic Two-Pole Circuit Breaker

 should be installed in AC electric power circuit in order to protect against   over-

current, short circuits, and earthing faults.
The circuit breaker contact gap should be no less than 3mm. Protective circuit breaker current must be in a 0,5A - 2A range. The 
circuit breaker should be placed close to the system's housing and should be easily accessed.

Before performing any work of installation or service 

always

 disconnect the device from power supplies in the following order:

   -   cut off the 230 VAC power line with the automatic Two-pole Circuit Breaker;
  -  disconnect the 12V back-up battery by removing battery female plug from a male socket BAT.
Two-pole Circuit-Beaker installation on flexible cables is forbidden.

General safety requirements:
 - do not touch any part of the main power supply under voltage: transformer, a fuse block, and connection wires;
 - it is forbidden to perform any device installation or service work during lightning;
 - use batteries as per manufacturer's recommendations. The use of improper battery type may cause an explosion;
 - battery replacement : make sure that battery terminals are isolated; battery terminals’ short-wiring   may cause an explosion.

It is not recommended to connect the device to a fully discharged battery.  

Inoperative or expired batteries should be recycled according to the local rules or   EU directives   2006/66/EC   and   93/86/EEC. 
Collection and separate utilization of waste battery is mandatory!

To avoid system malfunction use an adequate charger to 

charge a new or discharged battery before connecting battery to the   device.

Intruder alarm system comes with built

LEDs. The LEDs blink when device is powered up.

-in 

Connection to the main supply must be made as per local authorities rules and regulations. 
The end of a stranded conductor should not be consolidated by soft-soldering. Insulated pins should be used and connected in a
manner that they are and will remain mechanically efficient.

Device installation and service should be performed by trained personnel with sufficient knowledge about the device and general 
safety requirements to work with low voltage (up to 1000V) AC power lines. In case of device malfunction, repair works can only be 
performed by qualified personnel. If the system is malfunctioning, the end user should inform qualified personnel as soon as 
possible. The user is not allowed to repair the system. 

Fig. 1.

 

Automatic two-pole circuit breaker and power cable wiring diagram

Automatic two-pole 

circuit breaker

L

N

N

L

Cable from a power 

distribution board

Power cable to the 

alarm system

Cabinet of  the  alarm system (device)

Power supply distribution board

The device must be connected to AC power supply with Protective Earthing. Cable color and purpose: Phase or Live line (L) -   
black or brown cable, Neutral line (N)   - blue cable, Protective Earth line (PE) - green cable with a vertical yellow stripe. Please use 

2

only double isolated cables with a cross-sectional area of no less than 0,75 mm  for 230V. 

Page 1